Study of transient electromagnetic method measurements using a superconducting quantum interference device as B sensor receiver in polarizable survey area

被引:21
|
作者
Du, Shangyu [1 ,2 ]
Zhang, Yi [3 ,4 ]
Pei, Yifeng [3 ,4 ]
Jiang, Kun [3 ,5 ]
Rong, Liangliang [3 ,4 ]
Yin, Changchun [6 ]
Ji, Yanju [1 ,2 ]
Xie, Xiaoming [3 ,4 ]
机构
[1] Jilin Univ, Coll Instrumentat & Elect Engn, Changchun, Jilin, Peoples R China
[2] Natl Engn Res Ctr Geophys Explorat Instruments, Changchun, Jilin, Peoples R China
[3] Chinese Acad Sci, SIMIT, State Key Lab Funct Mat Informat, Shanghai, Peoples R China
[4] Ctr Excellence Superconducting Elect CENSE, Changchun, Jilin, Peoples R China
[5] ULANTECH Co Ltd, Shanghai, Peoples R China
[6] Jilin Univ, Coll Geoexplorat Sci & Technol, Changchun, Jilin, Peoples R China
关键词
AIRBORNE EM; SYSTEMS; SQUID; TEM;
D O I
10.1190/GEO2017-0197.1
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Time-domain transient electromagnetic method (TEM) measurements sometimes exhibit a sign reversal in the secondary field during the off-time, which is usually attributed to the induced- polarization (IP) effect. In contrast with the conventional IP method, which uses a current source, TEM with an ungrounded transmitting loop operates using a pure voltage source, which is induced by the primary field switching on and off. We performed TEM measurements in a resistive survey area showing an IP effect, and we used a low-temperature superconducting quantum interference device (LT-SQUID) with sensitivity of approximate to 10 fT/p Hz as a magnetic field sensor. A sign reversal in all of our measurements was observed; furthermore, the negative amplitude reached approximate to 10 pT. In-depth analysis with an extended version of a wire-filament circuit reveals that the large negative signal may be due to discharging of in-ground capacitance, an IP effect. The conduction response of the ground can be restored by subtracting the fitted discharging response (negative valued) from the observed data. To verify this operation, we compared TEM measurements with and without wireloop targets, which can induce a conduction field with a known decay time constant during the off-time. The extracted conduction responses of the wire-loop targets match the expected ones well. This research reveals that the primary field switch-off must always be included when interpreting TEM data with sign reversal and an LT-SQUID may be a good alternative sensor for studying the IP effect in TEM.
引用
收藏
页码:E111 / E116
页数:6
相关论文
共 19 条
  • [1] Nondestructive magnetic detection of plasticized area using superconducting quantum interference device
    Kasai, Naoko
    Chinone, Kazuo
    Nakayama, Satoshi
    Odawara, Akikazu
    Yamakawa, Hiroshi
    Ishikawa, Noboru
    Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes & Review Papers, 1998, 37 (11): : 5965 - 5970
  • [2] Nondestructive magnetic detection of plasticized area using superconducting quantum interference device
    Kasai, N
    Chinone, K
    Nakayama, S
    Odawara, A
    Yamakawa, H
    Ishikawa, N
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1998, 37 (11): : 5965 - 5970
  • [3] BIOMAGNETIC MEASUREMENTS IN UTERINE LEIOMYOMAS USING A SUPERCONDUCTING QUANTUM INTERFERENCE DEVICE (SQUID)
    ANASTASIADIS, PG
    ANNINOS, PA
    KOUTSOUGERAS, GC
    LIBERIS, VA
    GALAZIOS, GC
    SIVRIDIS, EL
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 1989, 29 (01) : 47 - 49
  • [4] Application of high temperature superconducting quantum interference devices in transient electromagnetic method for magnetotelluric soundings
    Wang, SG
    Zhang, LH
    Wang, CJ
    Dai, YD
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 1997, 282 : 411 - 414
  • [5] Switching device for the superconducting phase transition measurements of thin W films using a single superconducting quantum interference device
    Sáfrán, G
    Loidl, M
    Meier, O
    Angloher, G
    Pröbst, F
    Seidel, W
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (06): : 2815 - 2817
  • [6] Nonadiabatic heat-capacity measurements using a superconducting quantum interference device magnetometer
    Kharkovski, AI
    Binek, C
    Kleemann, W
    APPLIED PHYSICS LETTERS, 2000, 77 (15) : 2409 - 2411
  • [7] Measurements of biomagnetic fields using a high-resolution dc superconducting quantum interference device magnetometer
    Iramina, K
    Hong, B
    Uchida, S
    Goto, K
    Ueno, S
    Nakayama, S
    JOURNAL OF APPLIED PHYSICS, 1998, 83 (11) : 6465 - 6467
  • [8] BIOMAGNETIC MEASUREMENTS OF THE BRAIN ACTIVITY OF PREECLAMPTIC PREGNANT-WOMEN USING A SUPERCONDUCTING QUANTUM INTERFERENCE DEVICE
    ANNINOS, P
    ANASTASIADIS, P
    LIBERIS, V
    GALAZIOS, G
    KOUTSOUGERAS, G
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 1989, 30 (04) : 325 - 328
  • [9] Measurements of biomagnetic fields using a high-resolution dc superconducting quantum interference device magnetometer
    Univ of Tokyo, Tokyo, Japan
    Journal of Applied Physics, 1998, 83 (11 pt 2): : 6465 - 6467
  • [10] Measurements of stray magnetic fields of amorphous microwires using scanning microscope based on superconducting quantum interference device
    Gudoshnikov, S.
    Usov, N.
    Zhukov, A.
    Gonzalez, J.
    Palvanov, P.
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2007, 316 (02) : 188 - 191