Assay of oxytetracycline in animal feeds by liquid chromatography with fluorescence detection

被引:0
|
作者
Houglum, JE [1 ]
Larson, RD
Mutchler, DL
Wetzler, L
机构
[1] S Dakota State Univ, Dept Chem & Biochem, Brookings, SD 57007 USA
[2] Coll Pharm, Brookings, SD 57007 USA
[3] Nebraska Dept Agr, Lincoln, NE 68502 USA
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A liquid chromatographic (LC) method is described to assay oxytetracycline (OTC) in feeds at gram-per-ton and gram-per-pound levels. Complete feeds and premixes are extracted with acid-methanol, according to AOAC Method 957.23B(i), Extracts are filtered and quantitated by LC using a C-18 column and fluorescence detection with excitation at 390 nm and emission at 512 nm, The mobile phase (1.5 mL/min) uses a methanol gradient with an initial hold time of 1 min at 15% methanol followed by an increase to 35% methanol over 8 min. The aqueous component contains CaCl2, disodium ethylenediamine tetraacetate, and sodium acetate buffered to pH 6.5. Recovery of spiked samples averaged 101.6% (coefficients of variation, 0.1-2.4%), and the limit of detection was 1 g/ton, Results correlated closely with those obtained by using AOAC microbiological Method 968.50 and with another LC method using ultraviolet detection. OTC and epi-OTC elute at approximately 7.4 and 4.8 min, respectively. No interference was observed from several drugs and other antibiotics often used in feeds in combination with OTC.
引用
收藏
页码:919 / 922
页数:4
相关论文
共 50 条
  • [1] Assay of Oxytetracycline in Animal Feeds by Liquid Chromatography with Fluorescence Detection
    Houglum, Joel E.
    Larson, Richard D.
    Mutchler, Darrel L.
    Wetzler, Luann
    Journal of AOAC International, 81 (05): : 919 - 922
  • [2] Assay of chlortetracycline in animal feeds by liquid chromatography with fluorescence detection
    Houglum, JE
    Larson, RD
    Knutson, A
    JOURNAL OF AOAC INTERNATIONAL, 1997, 80 (05) : 961 - 965
  • [3] Analysis of Sulfonamides in Animal Feeds by Liquid Chromatography with Fluorescence Detection
    Borras, Silvia
    Companyo, Ramon
    Guiteras, Jacinto
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2011, 59 (10) : 5240 - 5247
  • [4] Analysis of fluoroquinolones in animal feeds by liquid chromatography with fluorescence detection
    Borras, Silvia
    Rios-Kristjansson, Juan-Gabriel
    Companyo, Ramon
    Prat, Maria-Dolors
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (16) : 2048 - 2053
  • [5] LIQUID-CHROMATOGRAPHY AND FLUORESCENCE DETECTION OF VITAMIN-A IN ANIMAL FEEDS, FINISHED FEEDS, AND PREMIXES
    THORPE, VA
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1990, 73 (03): : 463 - 466
  • [6] Assay and purity control of tetracycline, chlortetracycline and oxytetracycline in animal feeds and premixes by TLC densitometry with fluorescence detection
    Weng, ND
    Hua, S
    Roets, E
    Hoogmartens, J
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 33 (01) : 85 - 93
  • [7] Determination of methylbenzoquate in premixes and animal feeds USING liquid chromatography with fluorescence detection
    Douša, Michal
    Lemr, Karel
    Stránský, Zdeněk
    Journal of AOAC International, 1600, 88 (03): : 673 - 678
  • [8] Determination of methylbenzoquate in premixes and animal feeds USING liquid chromatography with fluorescence detection
    Dousa, M
    Lemr, K
    Stránsky, Z
    JOURNAL OF AOAC INTERNATIONAL, 2005, 88 (03) : 673 - 678
  • [10] Determination of Ivermectin in Medicated Feeds by Liquid Chromatography with Fluorescence Detection
    Pietruk, Konrad
    Jedziniak, Piotr
    SCIENTIFIC WORLD JOURNAL, 2013,