Evaluation of Long-term Performance of Composite Insulators for ±400kV Overhead Line on Tibet Plateau

被引:0
|
作者
Zhu, Yong [1 ]
Liu, Jun [1 ]
Luo, Yi [1 ]
Zhou, Shuchen [1 ]
Zhang, Xinxin [1 ]
机构
[1] Jiangsu Shemar Elect Co Ltd, Nantong, Jiangsu, Peoples R China
关键词
HTV silicone rubber; UV radiation; Composite insulator; Ageing performance; SILICONE;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The long-term performance of composite suspension insulators for a DC +/- 400kV overhead transmission line was evaluated after 6-year field operation on Tibet Plateau with high altitude and strong UV radiation. The study was performed under laboratory conditions. The overall electrical and mechanical performances of insulator were tested according to IEC 61109 after visual inspections and hydrophobicity class measurements. Thereafter, the mechanical strength and dielectric strength of high temperature vulcanized silicone rubber (HTV-SR) sheds were examined; furthermore, physicochemical analyses were conducted on the shed specimens. The results showed that the SR shed represented a very slight decrease in hydrophobicity, tensile strength, elongation at break, dielectric strength and have a stable chemical structure. It was demonstrated that the composite insulator with advanced HTV-SR sheath has long-term lifetime even operated under the extremely environmental stresses.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Evaluation of long-term performance of polymeric insulators for 22kV overhead distribution lines
    Akinori, O
    Hashimoto, Y
    Hikita, M
    Proceedings of the 2005 International Symposium on Electrical Insulating Materials, Vols, 1-3, 2005, : 119 - 122
  • [2] Performance of IPFC in a 400kV Transmission Line
    Charan, T. Vishnu
    Parimi, Alivelu M.
    2018 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENERGY SYSTEMS (ICEES), 2018, : 184 - 189
  • [3] Performance of 400 kV line insulators under pollution
    Arora, Ravindra
    Rai, Manoj
    Yadav, Satyendra Kumar
    CONFERENCE RECORD OF THE 2006 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2006, : 136 - +
  • [4] The lightning performance of a 400kV composite pylon with cable as down-lead
    Yin, Kai
    da Silva, Filipe Miguel Faria
    Bak, Claus Leth
    Zhang, Hanchi
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 220
  • [5] Fault Analysis and Treatment of Bird Dropping Flashover on ±400kV Qinghai-Tibet DC Transmission Line
    Zhou J.
    Zhang X.
    Wang S.
    Lü J.
    Wang J.
    Peng B.
    Wang X.
    Ding Y.
    Wang X.
    Yang M.
    Gao Y.
    Wang B.
    Dianwang Jishu/Power System Technology, 2020, 44 (03): : 1168 - 1174
  • [6] Reducing the failures with adding glass insulators to composite insulators of 400 kV transmission line at high altitude
    Alboyaci, Bora
    cinar, Mehmet Aytac
    Demirol, Yunus Berat
    Uzar, Mete
    ENGINEERING FAILURE ANALYSIS, 2022, 141
  • [7] Reducing the failures with adding glass insulators to composite insulators of 400 kV transmission line at high altitude
    Alboyacı, Bora
    Çınar, Mehmet Aytaç
    Demirol, Yunus Berat
    Uzar, Mete
    Engineering Failure Analysis, 2022, 141
  • [8] Improving the long-term performance of composite insulators use nanocomposite: A review
    Liang, Mu
    Wong, K. L.
    1ST INTERNATIONAL CONFERENCE ON ENERGY AND POWER, ICEP2016, 2017, 110 : 168 - 173
  • [9] Composite Insulators in a 400 kV AC Line in Algeria for Improving Electric Field Distribution
    Bouhaouche, Mohamed
    Mekhaldi, Abdelouahab
    Teguar, Madjid
    PROCEEDINGS 2018 3RD INTERNATIONAL CONFERENCE ON ELECTRICAL SCIENCES AND TECHNOLOGIES IN MAGHREB (CISTEM), 2018, : 94 - 98
  • [10] LONG-TERM AUDIBLE NOISE AND RADIO NOISE PERFORMANCE FROM AN OPERATING 400-KV TRANSMISSION-LINE
    LARSSON, C
    HALLBERG, B
    ISRAELSSON, S
    IEEE TRANSACTIONS ON POWER DELIVERY, 1988, 3 (04) : 1842 - 1846