Fibrin sealants in clinical practice

被引:95
|
作者
Albala, DM [1 ]
机构
[1] Duke Univ, Med Ctr, Durham, NC 27710 USA
来源
CARDIOVASCULAR SURGERY | 2003年 / 11卷
关键词
fibrin sealant; hemostasis; antifibrinolytic agents; physical properties; cardiovascular surgery; gastrointestinal surgery; pneumothoracic surgery; neurosurgery; urology; otolaryngology; RANDOMIZED TRIAL; CARDIAC OPERATIONS; GLUE; SURGERY; PREVENTION; ADHESIVES; CLOSURE; HEMORRHAGE; INJECTION; FISTULAS;
D O I
10.1016/S0967-2109(03)00065-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Fibrin sealants are used in a wide range of surgeries, primarily as hemostatic agents, but also to assist tissue sealing and wound healing. While all fibrin sealants contain fibrinogen and thrombin, they differ in their final composition. This affects the properties of the resulting fibrin clot and may influence their use in different surgical procedures. Sealants with high concentrations of fibrinogen tend to produce stronger clots, whereas those containing higher concentrations of thrombin form clots rapidly. This is essential when rapid hemostasis is required to stop blood loss (e.g. suturing of blood vessels). However, in situations that require careful adjustment of tissue (e.g. a skin flap) a slower clot formation is advantageous. Some sealants are supplemented with factor XIII and this may increase the tensile strength and stability of the clot and improve hemostasis. Antifibrinolytic agents (e.g. aprotinin and aminocaproic acid) increase the lifespan of the clot by inhibiting fibrinolysis. Fibrin sealants containing aprotinin may have an added advantage when used on surgical sites with naturally high concentrations of fibrinolytic agents. The physical properties of the fibrin sealants also vary. For example, the fibrinogen component is relatively viscous and requires a lot of force to inject it through a long catheter. Fibrin sealants with a fibrinogen component of low viscosity are easier to use than highly viscous solutions in surgical situations where the sealant is applied by a catheter. Until recently, the use of fibrin sealants in the USA has been limited to noncommercial products - 'home-brews'. The fibrinogen concentration of these products can vary between preparations, with subsequent variation in the mechanical strength of the clot making handling difficult. The introduction of commercial sealants into the USA with consistent composition should reduce the varying performance of fibrin sealants, although autologous and point-of-use prepared sealants may still vary. Consistency of performance is expected to result in an increased use of fibrin sealants both in established and novel fields of surgery. (C) 2003 The International Society for Cardiovascular Surgery. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:5 / 11
页数:7
相关论文
共 50 条
  • [1] Clinical applications of fibrin sealants
    Fattahi, T
    Mohan, M
    Caldwell, GT
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2004, 62 (02) : 218 - 224
  • [2] Fibrin sealants in surgical practice: An overview
    Jackson, MR
    AMERICAN JOURNAL OF SURGERY, 2001, 182 (02): : 1S - 7S
  • [3] Clinical impact of fibrin sealants
    Milne, AA
    VOX SANGUINIS, 2004, 87 : 29 - 30
  • [4] AUTOLOGOUS FIBRIN SEALANTS
    HUGHES, JI
    WESTWOOD, B
    THROMBOSIS AND HAEMOSTASIS, 1995, 73 (06) : 1471 - 1471
  • [5] Fibrin sealants and glues
    MacGillivray, TE
    JOURNAL OF CARDIAC SURGERY, 2003, 18 (06) : 480 - 485
  • [6] The safety of fibrin sealants
    Joch, C
    CARDIOVASCULAR SURGERY, 2003, 11 : 23 - 28
  • [7] New clinical perspectives from nurses on aprotinin and fibrin sealants
    Zoegall, Stephen G.
    JOURNAL OF VASCULAR NURSING, 2008, 26 (04) : 100 - 100
  • [8] Fibrin Sealants: Challenges and Solutions
    Beudert, Matthias
    Gutmann, Marcus
    Luehmann, Tessa
    Meinel, Lorenz
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2022, 8 (06): : 2220 - 2231
  • [9] Fibrin Sealants: Challenges and Solutions
    Beudert, Matthias
    Gutmann, Marcus
    Lühmann, Tessa
    Meinel, Lorenz
    ACS Biomaterials Science and Engineering, 2022, 8 (06): : 2220 - 2231
  • [10] The role of fibrin sealants in hemostasis
    Mankad, PS
    Codispoti, M
    AMERICAN JOURNAL OF SURGERY, 2001, 182 (02): : 21S - 28S