Internal elemental microanalysis combining x-ray fluorescence, Compton and transmission tomography

被引:123
|
作者
Golosio, B
Simionovici, A
Somogyi, A
Lemelle, L
Chukalina, M
Brunetti, A
机构
[1] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[2] ENS Lyon, Lab Sci Terre, F-69007 Lyon, France
[3] Russian Acad Sci, Inst Microelect Technol, Chernogolovka 142432, Moscow District, Russia
[4] Univ Sassari, Ist Matemat & Fis, I-07100 Sassari, Italy
关键词
D O I
10.1063/1.1578176
中图分类号
O59 [应用物理学];
学科分类号
摘要
Conventional x-ray transmission tomography provides the spatial distribution of the absorption coefficient inside a sample. Other tomographic techniques, based on the detection of photons coming from fluorescent emission, Compton and Rayleigh scattering, are used for obtaining information on the internal elemental composition of the sample. However, the reconstruction problem for these techniques is generally much more difficult than that of transmission tomography, mainly due to self-absorption effects in the sample. In this article an approach to the reconstruction problem is presented, which integrates the information from the three types of signals. This method provides the quantitative spatial distribution of all elements that emit detectable fluorescent lines (Zgreater than or equal to15 in usual experimental conditions), even when the absorption effects are strong, and the spatial distribution of the global density of the lighter elements. The use of this technique is demonstrated on the reconstruction of a grain of the martian meteorite NWA817, mainly composed of low Z elements not measured in fluorescence and for which this method provides a unique insight. The measurement was done at the ID22 beamline of the European Synchrotron Radiation Facility. (C) 2003 American Institute of Physics.
引用
收藏
页码:145 / 156
页数:12
相关论文
共 50 条
  • [1] Internal elemental microanalysis combining x-ray fluorescence, compton and transmission tomography
    Golosio, B. (golosio@esrf.fr), 1600, American Institute of Physics Inc. (94):
  • [2] Integrated Three-Dimensional Microanalysis Combining X-Ray Microtomography and X-Ray Fluorescence Methodologies
    Laforce, Brecht
    Masschaele, Bert
    Boone, Matthieu N.
    Schaubroeck, David
    Dierick, Manuel
    Vekemans, Bart
    Walgraeve, Christophe
    Janssen, Colin
    Cnudde, Veerle
    Van Hoorebeke, Luc
    Vincze, Laszlo
    ANALYTICAL CHEMISTRY, 2017, 89 (19) : 10617 - 10624
  • [3] X-ray Fluorescence Computed Tomography with a Compton Camera for a Clinical Application
    Vernekohl, Don
    Ahmad, Moiz
    Chinn, Garry
    Xing, Lei
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [4] Joint reconstruction of x-ray fluorescence and transmission tomography
    Di, Zichao Wendy
    Chen, Si
    Hong, Young Pyo
    Jacobsen, Chris
    Leyffer, Sven
    Wild, Stefan M.
    OPTICS EXPRESS, 2017, 25 (12): : 13107 - 13124
  • [5] X-ray Compton scattering tomography
    Webber, James
    INVERSE PROBLEMS IN SCIENCE AND ENGINEERING, 2016, 24 (08) : 1323 - 1346
  • [6] ELEMENTAL ANALYSES OF AUTORADIOGRAPHIC GRAINS BY X-RAY MICROANALYSIS
    ISHITANI, R
    MIYAKAWA, A
    IWAMOTO, T
    EXPERIENTIA, 1977, 33 (04): : 440 - 441
  • [7] Towards Zero Compton Background in X-ray Fluorescence Computed Tomography (XFCT)
    Nie, Xingchen
    Chen, Yunlai
    Meng, Ling-Jian
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [8] Feasibility study of Compton cameras for x-ray fluorescence computed tomography with humans
    Vernekohl, Don
    Ahmad, Moiz
    Chinn, Garry
    Xing, Lei
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (24): : 8521 - 8540
  • [9] X-ray Compton line scan tomography
    Kupsch, Andreas
    Lange, Axel
    Hentschel, Manfred P.
    Jaenisch, Gerd-Ruediger
    Kardjilov, Nikolay
    Toetzke, Christian
    Markoetter, Henning
    Hilger, Andre
    Manke, Ingo
    MATERIALS TESTING, 2015, 57 (11-12) : 985 - 991
  • [10] Correction for X-ray absorption in compton tomography
    Golosio, B
    Brunetti, A
    Cesareo, R
    JOURNAL DE PHYSIQUE IV, 2003, 104 : 651 - 654