A Calibration and 3-D Measurement Method for an Active Vision System With Symmetric Yawing Cameras

被引:15
|
作者
Xu, De [1 ,2 ]
Zhang, Di [1 ,2 ]
Liu, Xilong [1 ,2 ]
Ma, Liping [1 ,2 ]
机构
[1] Chinese Acad Sci, Res Ctr Precis Sensing & Control, Inst Automat, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Sch Artificial Intelligence, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
3-D measurement; active vision; calibration; stereo vision; symmetric yawing system; STEREO VISION;
D O I
10.1109/TIM.2021.3092517
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this study, we propose a 3-D measurement method for an active stereo vision system with two symmetric yawing cameras. First, we establish a measurement model with five constant systematic parameters and five variables. Second, we present a design for a relatively simple and convenient calibration method to determine the constant systematic parameters for the active vision system. In our proposed method, the initial yaw angles of two cameras are calibrated with a minimum of three equal interval points in a common field of view (FOV). The initial pitch angles are calibrated with at least one point in this common FOV. The initial yaw angles are used in the following calibration processes of the baseline length and the optical offset. The baseline length is calibrated with respect to two such points with known horizontal distance. An offset used to compensate for the difference between the actual optical centers of the two cameras along their optical axes is also computed with at least one feature point with the cameras yawed at different angles. Third, an associated measurement method for objects in the common FOV is presented. The proposed method computes 3-D positions of feature points in the common FOV using these five constant systematic parameters and five variables. This active stereo vision system design does not require repeated calibration for varying yaw of the two cameras to conduct measurements once the five constant systematic parameters have been calibrated offline. We conduct comparative experiments, and the results verify the effectiveness of the proposed method.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] 3-D ACTIVE VISION SYSTEM
    HAUGEN, PR
    KEIL, RE
    BOCCHI, C
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1985, 521 : 258 - 263
  • [2] Calibration Method of the 3-D Laser Sensor Measurement System
    Meng, Qing-Xu
    Zhao, Qi-Jie
    Tu, Da-Wei
    Yi, Jin-Gang
    WEARABLE SENSORS AND ROBOTS, 2017, 399 : 123 - 132
  • [3] Digital projector calibration for 3-D active vision systems
    Shen, TS
    Menq, CH
    JOURNAL OF MANUFACTURING SCIENCE AND ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (01): : 126 - 134
  • [4] 3-D visual measurement method using rotary vision system
    Hata, S
    Shima, D
    Hayashi, J
    Higashi, N
    Kaida, K
    PROCEEDINGS OF THE 2004 INTERNATIONAL CONFERENCE ON INTELLIGENT MECHATRONICS AND AUTOMATION, 2004, : 532 - 535
  • [5] Novel calibration method for 3-D measurement system based on fringe projection
    Chen, MY
    He, HT
    Guo, HW
    Third International Conference on Experimental Mechanics and Third Conference of the Asian-Committee-on-Experimental-Mechanics, Pts 1and 2, 2005, 5852 : 501 - 507
  • [6] 3-D Vision Measurement System and Method for Small-Diameter Pipeline
    Yang, Lemiao
    Zhou, Fuqiang
    Li, Xiaosong
    Zhang, Wanning
    Liu, Yang
    Tan, Haishu
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [7] In Situ Calibration of Binocular Vision System for 3-D Measurement of Particle Size During Crystallization
    Shuang, Yongcan
    Fan, Ji
    Liu, Tao
    Tan, Yonghong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [8] A Stereo Vision System for measurement of 3-D object
    Deng, WY
    Lu, NG
    Zhuang, JC
    Guo, SY
    Qu, XG
    AUTOMATED OPTICAL INSPECTION FOR INDUSTRY: THEORY, TECHNOLOGY, AND APPLICATIONS II, 1998, 3558 : 248 - 252
  • [9] 3-D vision sensor with multiple CCD cameras
    Hata, S
    Shima, D
    Kaida, K
    OPTOMECHATRONIC SYSTEMS III, 2002, 4902 : 246 - 253
  • [10] A 3D calibration method for binocular vision system
    He, Qing
    Ji, Zhiwen
    Li, Qingying
    Liu, Xu
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2025, 36 (01)