Catalytic oxidation of thiols at preheated glassy carbon electrode modified with abrasive immobilization of multiwall carbon nanotubes: applications to amperometric detection of thiocytosine, L-cysteine and glutathione

被引:160
|
作者
Salimi, A [1 ]
Hallaj, R [1 ]
机构
[1] Kurdistan Univ, Fac Sci, Dept Chem, Sanandaj, Iran
关键词
carbon nanotubes; modified electrode; preheated glassy carbon; thiol detection; amperometry;
D O I
10.1016/j.talanta.2004.12.040
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The performance of preheated glassy carbon electrode modified with carbon nanotubes is described. First glassy carbon electrode is heated for 5 min at 50 degrees C, then abrasive immobilization of multiwall carbon nanotubes on a preheated glassy carbon electrode was achieved by gentle rubbing of electrode surface on a filter paper supporting carbon nanotubes. Carbon nanotubes (CNTs)-modified glassy carbon electrodes exhibit strong and stable electrocatalytic response toward thiols oxidation in wide pH range. These properties permit an important decrease in over voltage for the oxidation of thiocytosine, glutathione and L-cysteine, as well as a dramatic increase in the peak currents in comparison with bare glassy carbon electrode. Furthermore, the thiols amperometric response of the coated electrodes is extremely stable, with more than 95% of the initial activity after 30 min stirring of 0.1 mM thiols. The electrocatalytic behavior is further exploited as a sensitive detection scheme for thiols detection by hydrodynamic amperometry. The substantial decrease in the overvoltage of the thiols oxidation associated with a stable amperometric response and antifouling properties of nanotubes films allow the development of highly sensitive thiols sensor without using any redox mediator. Such ability of carbon nanotubes to promote the thiols electron transfer reaction, short response time (5 s) and long-term stability, low detection limit, extended linear concentration range, high sensitivity suggest great promise for thiols amperometric sensors and detector for chromatographic analysis of thiol derivatives. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:967 / 975
页数:9
相关论文
共 50 条
  • [1] Amperometric detection of morphine at preheated glassy carbon electrode modified with multiwall carbon nanotubes
    Salimi, A
    Hallaj, R
    Khayatian, GR
    ELECTROANALYSIS, 2005, 17 (10) : 873 - 879
  • [2] Modified electrode using multi-walled carbon nanotubes and a metallopolymer for amperometric detection of L-cysteine
    Correa, Catia Crispilho
    Venturinelli Jannuzzi, Sergio Augusto
    Santhiago, Murilo
    Timm, Ronaldo Adriano
    Barboza Formiga, Andre Luiz
    Kubota, Lauro Tatsuo
    ELECTROCHIMICA ACTA, 2013, 113 : 332 - 339
  • [3] Electrocatalytic oxidation and sensitive determination of L-cysteine at a poly(aminoquinone)-carbon nanotubes hybrid film modified glassy carbon electrode
    Tu, Xinman
    Xie, Qingji
    Huang, Zhao
    Jia, Xue'en
    Ye, Min
    MICROCHIMICA ACTA, 2008, 162 (1-2) : 219 - 225
  • [4] Electrocatalytic oxidation and sensitive determination of l-cysteine at a poly(aminoquinone)-carbon nanotubes hybrid film modified glassy carbon electrode
    Xinman Tu
    Qingji Xie
    Zhao Huang
    Xue’en Jia
    Min Ye
    Microchimica Acta, 2008, 162 : 219 - 225
  • [5] Electrochemical behavior of L-cysteine and its detection at ordered mesoporous carbon-modified glassy carbon electrode
    Zhou, Ming
    Ding, Jie
    Guo, Li-ping
    Shang, Qing-kun
    ANALYTICAL CHEMISTRY, 2007, 79 (14) : 5328 - 5335
  • [6] SENSITIVE L-CYSTEINE AMPEROMETRIC SENSOR BASED ON A GLASSY CARBON ELECTRODE MODIFIED BY MnO2 NANOPARTICLES
    Liu, Suqin
    Luo, Tianxiong
    Li, Lin
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2013, 41 (04) : 382 - 393
  • [8] Oxidation and detection of L-cysteine using a modified Au/Nafion/glass carbon electrode
    Wang XueJi
    Zhang LiLi
    Miao LiXiao
    Kan MeiXiu
    Kong LinLin
    Zhang HuiMin
    SCIENCE CHINA-CHEMISTRY, 2011, 54 (03) : 521 - 525
  • [9] Oxidation and detection of L-cysteine using a modified Au/Nafion/glass carbon electrode
    XueJi Wang
    LiLi Zhang
    LiXiao Miao
    MeiXiu Kan
    LinLin Kong
    HuiMin Zhang
    Science China Chemistry, 2011, 54 : 521 - 525
  • [10] Oxidation and detection of L-cysteine using a modified Au/Nafion/glass carbon electrode
    WANG XueJiZHANG LiLiMIAO LiXiaoKAN MeiXiu KONG LinLinZHANG HuiMin School of ScienceBeijing Institute of TechnologyBeijing China
    Science China(Chemistry), 2011, 54 (03) : 521 - 525