The tunable diode laser absorption spectroscoty for measurement of NH3 with particles

被引:15
|
作者
Wang Fei [1 ]
Huang Qun-Xing [1 ]
Li Ning [1 ]
Yan Jian-Hua [1 ]
Chi Yong [1 ]
Cen Ke-Fa [1 ]
机构
[1] Zhejiang Univ, State Key Lab Clean Energy Utilizat, Hangzhou 310027, Peoples R China
关键词
TDLAS; wavelength modulation; NH3 concentration measurement; particle effect;
D O I
10.7498/aps.56.3867
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Tunable diode laser absorption spectroscopy (TDLAS) with wavelength modulaton is used to measure the NH3 concentration at normal temperature and pressure near 1531.7 nm in near-infrared region. The concentration of 25 ppm can be obtained by 10 m long-path cell, and concentration from 25 ppm to 400 ppm has good linear relationship with 2f signal. The effect of particles on 2f signal is discussed in this paper, and a solution of the problem using laser intensity linear fit to concentration measurement immune to particle disturbance is suggested.
引用
收藏
页码:3867 / 3872
页数:6
相关论文
共 7 条
  • [1] Dong F Z, 2005, J TEST MEASUREMENT T, V19, P119
  • [2] DONG FZ, 2005, J TEST MEASUREMENT T, V19, P237
  • [3] Absorption measurements of ambient methane with tunable diode laser
    Kan, RF
    Liu, WQ
    Zhang, YJ
    Liu, JG
    Dong, FZ
    Gao, SH
    Min, W
    Jun, C
    [J]. ACTA PHYSICA SINICA, 2005, 54 (04) : 1927 - 1930
  • [4] ANALYSIS OF THE HIGH-RESOLUTION SPECTRUM OF AMMONIA ((NH3)-N-14) IN THE NEAR-INFRARED REGION, 6400-6900-CM(-1)
    LUNDSBERGNIELSEN, L
    HEGELUND, F
    NICOLAISEN, FM
    [J]. JOURNAL OF MOLECULAR SPECTROSCOPY, 1993, 162 (01) : 230 - 245
  • [5] The HITRAN molecular spectroscopic database and HAWKS (HITRAN Atmospheric Workstation): 1996 edition
    Rothman, LS
    Rinsland, CP
    Goldman, A
    Massie, ST
    Edwards, DP
    Flaud, JM
    Perrin, A
    Camy-Peyret, C
    Dana, V
    Mandin, JY
    Schroeder, J
    McCann, A
    Gamache, RR
    Wattson, RB
    Yoshino, K
    Chance, KV
    Jucks, KW
    Brown, LR
    Nemtchinov, V
    Varanasi, P
    [J]. JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1998, 60 (05): : 665 - 710
  • [6] A potential remote sensor of CO in vehicle exhausts using 2.3 μm diode lasers
    Wang, J
    Maiorov, M
    Jeffries, JB
    Garbuzov, DZ
    Connolly, JC
    Hanson, RK
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2000, 11 (11) : 1576 - 1584
  • [7] Ammonia monitoring near 1.5 μm with diode-laser absorption sensors
    Webber, ME
    Baer, DS
    Hanson, RK
    [J]. APPLIED OPTICS, 2001, 40 (12) : 2031 - 2042