Coil model comparison for cerebellar transcranial magnetic stimulation

被引:18
|
作者
Can, M. Kaan [1 ,2 ]
Laakso, Ilkka [1 ]
Nieminen, Jaakko O. [2 ,3 ]
Murakami, Takenobu [4 ]
Ugawa, Yoshikazu [4 ]
机构
[1] Aalto Univ, Dept Elect Engn & Automat, Espoo, Finland
[2] Aalto Univ, Dept Neurosci & Biomed Engn, Espoo, Finland
[3] Aalto Univ, Aalto TMS Lab, Aalto Neuroimaging, Espoo, Finland
[4] Fukushima Med Univ, Dept Neurol, Fukushima, Japan
来源
关键词
transcranial magnetic stimulation; magnetic coil; cerebellum; electric field; patient-specific modelling; finite-element method; ELECTRIC-FIELD; TMS; GEOMETRY; ATAXIA;
D O I
10.1088/2057-1976/aaee5b
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective. Transcranial magnetic stimulation (TMS) has been increasingly used for investigating the function of different areas of the cerebellum. Experimental studies have shown variable effectiveness of different types of coils in cerebellar TMS. Our objective is to systematically investigate the effects of coil type on the electric field (E-field) induced in the cerebellum. Approach. Induced E-fields of cerebellar TMS were modelled using individualised head models of 15 subjects. A double-cone, a figure-of-8 and a round coil were modelled, and E-field measurements were performed to validate the coil models. The E-fields induced in anatomical models are statistically analysed to investigate the effects of the coil type and placement on the stimulation strength, depth and focality. Main results. The E-field measurements showed that the applied thin-wire approximation is valid and useful for computational modelling of TMS coils. Inter-subject analysis of the induced E-fields showed that the round coil systematically produced the weakest E-fields. The difference between the double-cone and figure-of-8 coils was not systematic; instead, the most efficient coil type depended on the targeted region of the cerebellum. Further, despite inter-subject differences, the double-cone coil appeared more suitable for stimulating deeper regions of the cerebellum, whereas the figure-of-8 coil produces more focal stimulation, hence providing precise stimulation of regions closer to the scalp surface. Significance. The double-cone, round and figure-of-8 coils have different advantages over each other in different situations. The choice of the coil geometry and placement should be made with care for the desired stimulation outcome. Moreover, inter-subject anatomical differences affect the E-field induced in the cerebellum, and anatomical modelling using magnetic resonance imaging data can enhance the precision of cerebellar TMS.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Comparison of Coil Designs for Transcranial Magnetic Stimulation of a Pig Model
    Afuwape, Oluwaponmile F.
    Runge, Jenna
    Bentil, Sarah A.
    Jiles, David C.
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 1535 - 1538
  • [2] Cerebellar Transcranial Magnetic Stimulation: The Role of Coil Geometry and Tissue Depth
    Hardwick, Robert M.
    Lesage, Elise
    Miall, R. Chris
    BRAIN STIMULATION, 2014, 7 (05) : 643 - 649
  • [3] Circular Coil Array Model for Transcranial Magnetic Stimulation
    Yang, Shuo
    Xu, Guizhi
    Wang, Lei
    Geng, Yaohua
    Yu, Hongli
    Yang, Qingxin
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) : 829 - 833
  • [4] Cerebellar transcranial magnetic stimulation: The role of coil type from distinct manufacturers
    Spampinato, Danny
    Ibanez, Jaime
    Spanoudakis, Manos
    Hammond, Paul
    Rothwell, John C.
    BRAIN STIMULATION, 2020, 13 (01) : 153 - 156
  • [5] Investigation of Coil Designs for Transcranial Magnetic Stimulation on Realistic Head model
    Rahman, Md Marufi
    Hosain, Md Kamal
    Ahmed, Shihab
    Al Azad, Md Washik
    2017 IEEE REGION 10 HUMANITARIAN TECHNOLOGY CONFERENCE (R10-HTC), 2017, : 279 - 283
  • [6] The optimal design of magnetic coil in transcranial magnetic stimulation
    Xu, Guizhi
    Chen, Yong
    Yang, Shuo
    Wang, Mingshi
    Yan, Weili
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 6221 - 6224
  • [7] Modeling transcranial magnetic stimulation coil with magnetic cores
    Makaroff, Sergey N.
    Nguyen, Hieu
    Meng, Qinglei
    Lu, Hanbing
    Nummenmaa, Aapo R.
    Deng, Zhi-De
    JOURNAL OF NEURAL ENGINEERING, 2023, 20 (01)
  • [8] Optimal Coil Orientation for Transcranial Magnetic Stimulation
    Richter, Lars
    Neumann, Gunnar
    Oung, Stephen
    Schweikard, Achim
    Trillenberg, Peter
    PLOS ONE, 2013, 8 (04):
  • [9] Comparison of the Effect of Coil Configuration and the Variability of Anatomical Structure on Transcranial Magnetic Stimulation
    Afuwape, Oluwaponmile F.
    Rastogi, Priyam
    Jiles, David C.
    IEEE TRANSACTIONS ON MAGNETICS, 2021, 57 (02)
  • [10] Transcranial magnetic stimulation in patients with cerebellar stroke
    CruzMartinez, A
    Arpa, J
    EUROPEAN NEUROLOGY, 1997, 38 (02) : 82 - 87