Experimental Investigation on the Thermal Performance of Pulsating Heat Pipe Heat Exchangers

被引:9
|
作者
Yang, Kai-Shing [1 ]
Jiang, Ming-Yean [2 ]
Tseng, Chih-Yung [3 ]
Wu, Shih-Kuo [3 ]
Shyu, Jin-Cherng [2 ]
机构
[1] Natl Chin Yi Univ Technol, Dept Refrigerat Air Conditioning & Energy Engn, Taichung 41170, Taiwan
[2] Natl Kaohsiung Univ Sci & Technol, Dept Mech Engn, Kaohsiung 80778, Taiwan
[3] Ind Technol Res Inst, Green Energy & Environm Res Labs, Hsinchu 31040, Taiwan
关键词
heat exchanger; effectiveness; thermal resistance; HFE-7000; NON-CONDENSABLE GAS; START-UP; PART; VISUALIZATION; FABRICATION;
D O I
10.3390/en13010269
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this study, the vertically-oriented pulsating heat pipe (PHP) heat exchangers charged with either water or HFE-7000 in a filling ratio of 35% or 50% were fabricated to exchange the thermal energy between two air streams in a parallel-flow arrangement. Both the effectiveness of the heat exchangers and the thermal resistance of PHP with a size of 132 x 44 x 200 mm, at a specific evaporator temperature ranging from 55 to 100 degrees C and a specific airflow velocity ranging from 0.5 to 2.0 m/s were estimated. The results show that the heat pipe charged with HFE-7000 in either filling ratio is likely to function as an interconnected array of thermosiphon under all tested conditions because of the unfavorable tube inner diameter, whereas the water-charged PHP possibly creates the pulsating movement of the liquid and vapor slugs once the evaporator temperature is high enough, especially in a filling ratio of 50%. The degradation in the thermal performance of the HFE-7000-charged PHP heat exchanger resulted from the non-condensable gas in the tube became diminished as the evaporator temperature was increased. By examining the effectiveness of the present heat exchangers, it is suggested that water is a suitable working fluid while employing the PHP heat exchanger at an evaporator temperature higher than 70 degrees C. On the other hand, HFE-7000 is applicable to the PHP used at an evaporator temperature lower than 70 degrees C.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] EXPERIMENTAL INVESTIGATION ON PERFORMANCE OF PULSATING HEAT PIPE
    Prasad, Tarigonda Hari
    Kukutla, Pol Reddy
    Rao, P. Mallikarjuna
    Reddy, R. Meenakshi
    PROCEEDINGS OF THE ASME GAS TURBINE INDIA CONFERENCE, 2015, 2016,
  • [2] An experimental investigation on heat transfer performance of pulsating heat pipe
    Fumin Shang
    Shilong Fan
    Qingjing Yang
    Jianhong Liu
    Journal of Mechanical Science and Technology, 2020, 34 : 425 - 433
  • [3] An experimental investigation on heat transfer performance of pulsating heat pipe
    Shang, Fumin
    Fan, Shilong
    Yang, Qingjing
    Liu, Jianhong
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2020, 34 (01) : 425 - 433
  • [4] EXPERIMENTAL INVESTIGATION OF CIRCULATING MOTION ON THE THERMAL PERFORMANCE OF A PULSATING HEAT PIPE
    Kim, Wookyoung
    Kim, Sung Jin
    4TH THERMAL AND FLUIDS ENGINEERING CONFERENCE, ASTFE 2019, 2019,
  • [5] An Experimental Investigation on Heat Transfer Performance of Nanofluid Pulsating Heat Pipe
    Hongwei Jia
    Li Jia
    Zetao Tan
    Journal of Thermal Science, 2013, 22 (05) : 484 - 490
  • [6] An Experimental Investigation on Heat Transfer Performance of Nanofluid Pulsating Heat Pipe
    Jia, Hongwei
    Jia, Li
    Tan, Zetao
    JOURNAL OF THERMAL SCIENCE, 2013, 22 (05) : 484 - 490
  • [7] An experimental investigation on heat transfer performance of nanofluid pulsating heat pipe
    Hongwei Jia
    Li Jia
    Zetao Tan
    Journal of Thermal Science, 2013, 22 : 484 - 490
  • [8] An experimental investigation of thermal performance of pulsating heat pipe with alcohols and surfactant solutions
    Bastakoti, Durga
    Zhang, Hongna
    Cai, Weihua
    Li, Fengchen
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 117 : 1032 - 1040
  • [9] Experimental investigation on the thermal performance of helium based cryogenic pulsating heat pipe
    Xu, Dong
    Li, Laifeng
    Liu, Huiming
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2016, 70 : 61 - 68
  • [10] Experimental investigation of the influence of surfactant on the heat transfer performance of pulsating heat pipe
    Wang, X. H.
    Zheng, H. C.
    Si, M. Q.
    Han, X. H.
    Chen, G. M.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 83 : 586 - 590