Endocoil magnetic resonance imaging quantification of external anal sphincter atrophy

被引:37
|
作者
Williams, AB
Bartram, CI
Modhwadia, D
Nicholls, T
Halligan, S
Kamm, MA
Nicholls, RJ
Kmiot, WA
机构
[1] St Marks Hosp, Dept Intestinal Imaging, Harrow HA1 3UJ, Middx, England
[2] St Marks Hosp, Dept Physiol, Harrow, Middx, England
[3] St Marks Hosp, Dept Surg, Harrow, Middx, England
[4] St Thomas Hosp, Dept Surg, London SE1 7EH, England
关键词
D O I
10.1046/j.0007-1323.2001.01796.x
中图分类号
R61 [外科手术学];
学科分类号
摘要
Anal function depends on the integrity and quality of the sphincter muscles. The diagnosis of external anal sphincter atrophy on endocoil magnetic resonography has been associated with poor outcome from sphincter repair, although the imaging criteria for atrophy remain unclear. Women with intact sphincters on endosonography and either normal (more than 60 cmH(2)O) (n = 9) or low (n = 16) squeeze pressures had endocoil magnetic resonography and electromyography. The area and fat content of the external anal sphincter and puborectalis were measured on mid-coronal magnetic resonography and images were graded as showing normal, intermediate or advanced atrophy. The definition of the external anal sphincter on endosonography and the thickness of the internal anal sphincter were also assessed. Women with a normal anal squeeze pressure had a larger external anal sphincter cross-sectional area (mean(s.d.) 240(56) versus 193(62) mm(2); P = 0.01) with a lower mean fat content (mean(s.d.) 23(4) versus 30(6) per cent; P < 0.001) than those with low squeeze pressures. There was an overall correlation between squeeze pressure, cross-sectional area (r = 0.32, P = 0.02) and fat content (r = - 0.51, P < 0.001). Patients with a thin (less than 2 mm) internal anal sphincter and/or a poorly defined external sphincter on endosonography were more likely to have atrophy (positive predictive value 74 per cent). Potential endosonographic markers for external anal sphincter atrophy are suggested, and a visual scale for endocoil magnetic resonographic assessment has been validated.
引用
收藏
页码:853 / 859
页数:7
相关论文
共 50 条
  • [1] Magnetic resonance imaging quantification of external anal sphincter atrophy
    Williams, AB
    Bartram, CI
    Modhwadia, D
    Nicholls, T
    Halligan, S
    Kamm, MA
    Nicholls, RJ
    Kmiot, WA
    BRITISH JOURNAL OF SURGERY, 2001, 88 : 26 - 26
  • [2] Assessment of external anal sphincter morphology in idiopathic fecal incontinence with endocoil magnetic resonance imaging
    Williams, AB
    Malouf, AJ
    Bartram, CI
    Halligan, S
    Kamm, MA
    Kmiot, WA
    DIGESTIVE DISEASES AND SCIENCES, 2001, 46 (07) : 1466 - 1471
  • [3] Assessment of External Anal Sphincter Morphology in Idiopathic Fecal Incontinence with Endocoil Magnetic Resonance Imaging
    A.B. Williams
    A.J. Malouf
    C.I. Bartram
    S. Halligan
    M.A. Kamm
    W.A. Kmiot
    Digestive Diseases and Sciences, 2001, 46 : 1466 - 1471
  • [4] External anal sphincter atrophy on endoanal magnetic resonance imaging adversely affects continence after sphincteroplasty
    Briel, JW
    Stoker, J
    Rociu, E
    Laméris, JS
    Hop, WCJ
    Schouten, WR
    BRITISH JOURNAL OF SURGERY, 1999, 86 (10) : 1322 - 1327
  • [5] Atrophy and defects detection of the external anal sphincter: Comparison between three-dimensional anal endosonography and endoanal magnetic resonance imaging
    Cazemier, M
    Terra, MP
    Stoker, J
    de Lange-de Klerk, E
    Boeckxstaens, GEE
    Mulder, CJJ
    Felt-Bersma, RJF
    DISEASES OF THE COLON & RECTUM, 2006, 49 (01) : 20 - 27
  • [6] Atrophy and Defects Detection of the External Anal Sphincter: Comparison between Three-Dimensional Anal Endosonography and Endoanal Magnetic Resonance Imaging
    Cazemier, Marcel
    Terra, Maaike P.
    Stoker, Jaap
    de Lange-de Klerk, Elly S. M.
    Boeckxstaens, Guy E. E.
    Mulder, Chris J. J.
    Felt-Bersma, Richelle J. F.
    COLOPROCTOLOGY, 2006, 28 (04) : 208 - 216
  • [7] Endosonographic anatomy of the normal anal canal compared with endocoil magnetic resonance imaging
    Williams, AB
    Bartram, CI
    Halligan, S
    Marshall, MM
    Nicholls, RJ
    Kmiot, WA
    DISEASES OF THE COLON & RECTUM, 2002, 45 (02) : 176 - 183
  • [8] Can three-dimensional endoanal ultrasonography detect external anal sphincter atrophy? A comparison with endoanal magnetic resonance imaging
    West, RL
    Dwarkasing, S
    Briel, JW
    Hansen, BE
    Hussain, SM
    Schouten, WR
    Kuipers, EJ
    GASTROENTEROLOGY, 2005, 128 (04) : A270 - A270
  • [9] Can three-dimensional endoanal ultrasonography detect external anal sphincter atrophy? A comparison with endoanal magnetic resonance imaging
    R. L. West
    S. Dwarkasing
    J. W. Briel
    B. E. Hansen
    S. M. Hussain
    W. R. Schouten
    E. J. Kuipers
    International Journal of Colorectal Disease, 2005, 20 : 328 - 333
  • [10] Can three-dimensional endoanal ultrasonography detect external anal sphincter atrophy? A comparison with endoanal magnetic resonance imaging
    West, RL
    Dwarkasing, S
    Briel, JW
    Hansen, BE
    Hussain, SM
    Schouten, WR
    Kuipers, EJ
    INTERNATIONAL JOURNAL OF COLORECTAL DISEASE, 2005, 20 (04) : 328 - 333