Effects of coupling methods on galvanic corrosion behavior of commercially pure titanium with dental precious alloys

被引:0
|
作者
Al-Ali, S
Oshida, Y
Andres, CJ
Barco, MT
Brown, DT
Hovijitra, S
Ito, M
Nagasawa, S
Yoshida, T
机构
[1] Indiana Univ, Sch Dent, Dept Restorat Dent, Dent Mat Div, Indianapolis, IN 46202 USA
[2] Rashid Hosp, Dept Prosthodont, Dubai, U Arab Emirates
[3] Indiana Univ, Sch Dent, Dept Restorat Dent, Prosthodont Div, Indianapolis, IN USA
[4] Matsumoto Dent Univ, Dept Dent Mat, Shiojiri, Nagano, Japan
关键词
galvanic corrosion; crevice corrosion; coupling mode; titanium; dental precious alloys; discoloration;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: When a dissimilar couple is exposed to corrosive environment, it will normally exhibit a galvanic corrosion. The galvanic corrosion might be influenced by various factors, including type and concentration of electrolyte, surface area ratio between anode and cathode, type of coupling material, and coupling manner. Purpose: The purpose of this study was to investigate and compare the galvanic corrosion behavior of commercially pure titanium when coupled with type IV Au alloy, Au-Ag-Pt alloy, and Ag-Au-Pd alloy by different coupling methods. Materials and methods: Couples were prepared by a laser welding or a mechanical adhering method. Electrochemical corrosion studies were conducted in a Ringer's solution at a scanning rate of 0.1 mV/sec in a range from -250 mV to +250 mV with respect to E-OCP. Corrosion parameters (E-OCP, I-CORR, E-CORR) were obtained. Results: It was found that (i) there was a significant difference between LWC and AJC for three couples (p < 0.05), (ii) the crevice line caused all three couples more corrosive than weld joint line, (iii) for both joint, it was found that type (IV) Au alloy exhibited discoloration to some extent. Conclusions: It is concluded that among the three couples with two different coupling methods, Ti/Ag-Au-Pd couple exhibited best corrosion resistance in a room temperature Ringer's solution.
引用
收藏
页码:307 / 316
页数:10
相关论文
共 50 条
  • [1] Galvanic corrosion behavior of titanium implants coupled to dental alloys
    Cortada, M
    Giner, LL
    Costa, S
    Gil, FJ
    Rodríguez, D
    Planell, JA
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2000, 11 (05) : 287 - 293
  • [2] Galvanic corrosion behavior of titanium implants coupled to dental alloys
    M. Cortada
    Ll. Giner
    S. Costa
    F. J. Gil
    D. Rodri´guez
    J. A. Planell
    Journal of Materials Science: Materials in Medicine, 2000, 11 : 287 - 293
  • [3] Investigation of Corrosion Behavior of Bioactive Coverings on Commercially Pure Titanium and its Alloys
    Gazizova, M. Yu.
    Ivanov, M. B.
    Vershinina, T. N.
    JOURNAL OF NANO- AND ELECTRONIC PHYSICS, 2015, 7 (04)
  • [4] EFFECTS OF GALVANIC COUPLING BETWEEN DENTAL ALLOYS
    MEYER, JM
    SUSZ, CP
    JOURNAL OF DENTAL RESEARCH, 1981, 60 : 1220 - 1220
  • [5] Galvanic corrosion behavior of implant suprastructure dental alloys
    Taher, NM
    Al Jabab, AS
    DENTAL MATERIALS, 2003, 19 (01) : 54 - 59
  • [6] GALVANIC CORROSION OF DENTAL ALLOYS
    ZITTER, H
    PITNER, P
    DEUTSCHE ZAHNARZTLICHE ZEITSCHRIFT, 1983, 38 (05): : 557 - 559
  • [7] The effect of mucine, IgA, urea, and lysozyme on the corrosion Behavior of various non-precious dental alloys and pure titanium in artificial saliva
    Bilhan, H.
    Bilgin, T.
    Cakir, A. F.
    Yuksel, B.
    von Fraunhofer, J. A.
    JOURNAL OF BIOMATERIALS APPLICATIONS, 2007, 22 (03) : 197 - 221
  • [8] Stress corrosion cracking behavior of commercially pure titanium.
    Huang, HH
    Hsu, CC
    Huang, MS
    JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1378 - 1378
  • [9] Galvanic corrosion between dental precious alloys and magnetic stainless steels used for dental magnetic attachments
    Takahashi, Noriko
    Takada, Yukyo
    Okuno, Osamu
    DENTAL MATERIALS JOURNAL, 2008, 27 (02) : 237 - 242
  • [10] Effects of fluoride and dissolved oxygen concentrations on the corrosion behavior of pure titanium, and titanium alloys
    Nakagawa, M
    Matsuya, S
    Udoh, K
    DENTAL MATERIALS JOURNAL, 2002, 21 (02) : 83 - 92