Cardiac testing for coronary artery disease in potential kidney transplant recipients

被引:70
|
作者
Wang, Louis W. [1 ]
Fahim, Magid A. [2 ]
Hayen, Andrew [3 ]
Mitchell, Ruth L. [4 ]
Baines, Laura [5 ]
Lord, Stephen [6 ]
Craig, Jonathan C. [4 ]
Webster, Angela C. [4 ,7 ]
机构
[1] St Vincents Hosp, Dept Cardiol, Darlinghurst, NSW 2010, Australia
[2] Princess Alexandra Hosp, Dept Nephrol, Brisbane, Qld 4102, Australia
[3] Univ Sydney, Sydney Sch Publ Hlth, STEP, Sydney, NSW 2006, Australia
[4] Childrens Hosp Westmead, Ctr Kidney Res, Cochrane Renal Grp, Westmead, NSW, Australia
[5] Newcastle Upon Tyne Hosp NHS, Renal Serv, Newcastle Upon Tyne, Tyne & Wear, England
[6] Newcastle Upon Tyne Hosp NHS, Serv Cardiol, Newcastle Upon Tyne, Tyne & Wear, England
[7] Univ Sydney, Westmead Millennium Inst, Ctr Transplant & Renal Res, Westmead, NSW 2145, Australia
基金
英国医学研究理事会;
关键词
DOBUTAMINE STRESS ECHOCARDIOGRAPHY; STAGE RENAL-DISEASE; DIAGNOSTIC-TEST ACCURACY; HIGH-RISK PATIENTS; PROGNOSTIC VALUE; DIABETIC-PATIENTS; HEMODIALYSIS-PATIENTS; CARDIOVASCULAR RISK; MYOCARDIAL SCINTIGRAPHY; FLOW RESERVE;
D O I
10.1002/14651858.CD008691.pub2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Patients with chronic kidney disease (CKD) are at increased risk of coronary artery disease (CAD) and adverse cardiac events. Screening for CAD is therefore an important part of preoperative evaluation for kidney transplant candidates. There is significant interest in the role of non-invasive cardiac investigations and their ability to identify patients at high risk of CAD. Objectives We investigated the accuracy of non-invasive cardiac screening tests compared with coronary angiography to detect CAD in patients who are potential kidney transplant recipients. Search methods MEDLINE and EMBASE searches (inception to November 2010) were performed to identify studies that assessed the diagnostic accuracy of non-invasive screening tests, using coronary angiography as the reference standard. We also conducted citation tracking via Web of Science and handsearched reference lists of identified primary studies and review articles. Selection criteria We included in this review all diagnostic cross sectional, cohort and randomised studies of test accuracy that compared the results of any cardiac test with coronary angiography (the reference standard) relating to patients considered as potential candidates for kidney transplantation or kidney-pancreas transplantation at the time diagnostic tests were performed. Data collection and analysis We used a hierarchical modelling strategy to produce summary receiver operating characteristic (SROC) curves, and pooled estimates of sensitivity and specificity. Sensitivity analyses to determine test accuracy were performed if only studies that had full verification or applied a threshold of >= 70% stenosis on coronary angiography for the diagnosis of significant CAD were included. Main results The following screening investigations included in the meta-analysis were: dobutamine stress echocardiography (DSE) (13 studies), myocardial perfusion scintigraphy (MPS) (nine studies), echocardiography (three studies), exercise stress electrocardiography (two studies), resting electrocardiography (three studies), and one study each of electron beam computed tomography (EBCT), exercise ventriculography, carotid intimal media thickness (CIMT) and digital subtraction fluorography (DSF). Sufficient studies were present to allow hierarchical summary receiver operating characteristic (HSROC) analysis for DSE and MPS. When including all available studies, both DSE and MPS had moderate sensitivity and specificity in detecting coronary artery stenosis in patients who are kidney transplant candidates [DSE (13 studies) - pooled sensitivity 0.79 (95% CI 0.67 to 0.88), pooled specificity 0.89 (95% CI 0.81 to 0.94); MPS (nine studies) - pooled sensitivity 0.74 (95% CI 0.54 to 0.87), pooled specificity 0.70 (95% CI 0.51 to 0.84)]. When limiting to studies which defined coronary artery stenosis using a reference threshold of >= 70% stenosis on coronary angiography, there was little change in these pooled estimates of accuracy [DSE (9 studies) - pooled sensitivity 0.76 (95% CI 0.60 to 0.87), specificity 0.88 (95% CI 0.78 to 0.94); MPS (7 studies) - pooled sensitivity 0.67 (95% CI 0.48 to 0.82), pooled specificity 0.77 (95% CI 0.61 to 0.88)]. There was evidence that DSE had improved accuracy over MPS (P = 0.02) when all studies were included in the analysis, but this was not significant when we excluded studies which did not avoid partial verification or use a reference standard threshold of >= 70% stenosis (P = 0.09). Authors' conclusions DSE may perform better than MPS but additional studies directly comparing these cardiac screening tests are needed. Absence of significant CAD may not necessarily correlate with cardiac-event free survival following transplantation. Further research should focus on assessing the ability of functional tests to predict postoperative outcome.
引用
收藏
页数:106
相关论文
共 50 条
  • [1] Cardiac testing for coronary artery disease in potential kidney transplant recipients
    Webster, Angela
    Wang, Louis
    NEPHROLOGY, 2012, 17 (05) : 519 - 520
  • [2] Cardiac Testing for Coronary Artery Disease in Potential Kidney Transplant Recipients: A Systematic Review of Test Accuracy Studies
    Wang, Louis W.
    Fahim, Magid A.
    Hayen, Andrew
    Mitchell, Ruth L.
    Lord, Stephen W.
    Baines, Laura A.
    Craig, Jonathan C.
    Webster, Angela C.
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2011, 57 (03) : 476 - 487
  • [3] Coronary artery disease in cardiac transplant recipients
    Stehbens, WE
    MEDICAL JOURNAL OF AUSTRALIA, 1996, 164 (04) : 254 - 255
  • [4] Hyperhomocysteinemia and transplant coronary artery disease in cardiac transplant recipients
    Miner, SES
    Cole, DEC
    Evrovski, J
    Verma, A
    Daly, PA
    Ross, HJ
    CLINICAL TRANSPLANTATION, 2001, 15 (04) : 258 - 262
  • [5] CORONARY-ARTERY DISEASE IN CARDIAC TRANSPLANT RECIPIENTS
    KEOGH, AM
    MEDICAL JOURNAL OF AUSTRALIA, 1995, 163 (04) : 212 - 214
  • [7] Screening for occult coronary artery disease in potential kidney transplant recipients: time for reappraisal?
    Ferro, Charles J.
    Berry, Miriam
    Moody, William E.
    George, Sudhakar
    Sharif, Adnan
    Townend, Jonathan N.
    CLINICAL KIDNEY JOURNAL, 2021, 14 (12) : 2472 - 2482
  • [8] Evaluation of Coronary Artery Disease in Potential Liver Transplant Recipients
    Hogan, Brian J.
    Gonsalkorala, Enoka
    Heneghan, Michael A.
    LIVER TRANSPLANTATION, 2017, 23 (03) : 386 - 395
  • [9] Diagnostic accuracy of cardiac testing for coronary artery disease in potential liver transplant recipients: A systematic review and meta-analysis
    Tiwari, Nidhish
    Margapuri, Jyothi
    Katamreddy, Adarsh
    Jubbal, Sandeep
    Madan, Nidhi
    IJC HEART & VASCULATURE, 2021, 32
  • [10] Outcomes of Interventional Management of Coronary Artery Disease in Kidney Transplant Recipients
    Chawla, Sanchit
    Lak, Hassan Mehmood
    Sammour, Yasser
    Ahmed, Taha
    Gunasekaran, Deepthi
    Mutti, Jasmine
    Kaur, Manpreet
    Chahine, Johnny
    Ellis, Stephen
    Mansour, John
    Khatri, Jaikirshan
    Simpfendorfer, Conrad
    Kapadia, Samir
    TRANSPLANTATION PROCEEDINGS, 2022, 54 (03) : 663 - 670