Electrochemical DNA Sensor Based on Carbon Black-Poly(Methylene Blue)-Poly(Neutral Red) Composite

被引:16
|
作者
Kappo, Dominica [1 ]
Shurpik, Dmitry [1 ]
Padnya, Pavel [1 ]
Stoikov, Ivan [1 ]
Rogov, Alexey [2 ]
Evtugyn, Gennady [1 ,3 ]
机构
[1] Kazan Fed Univ, AM Butlerov Chem Inst, 18 Kremlevskaya St, Kazan 420008, Russia
[2] Kazan Fed Univ, Interdisciplinary Ctr, Analyt Microscopy, 18 Kremlevskaya St, Kazan 420008, Russia
[3] Ural Fed Univ, Chem Technol Inst, Analyt Chem Dept, 19 Mira St, Ekaterinburg 620002, Russia
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 05期
基金
俄罗斯基础研究基金会; 俄罗斯科学基金会;
关键词
DNA sensor; electropolymerization; Methylene blue; Neutral red; pillar [5]arene; doxorubicin determination; voltametric sensor; BIOSENSORS; PLASMA; DYES;
D O I
10.3390/bios12050329
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The detection of small molecules interacting with DNA is important for the assessment of potential hazards related to the application of rather toxic antitumor drugs, and for distinguishing the factors related to thermal and oxidative DNA damage. In this work, a novel electrochemical DNA sensor has been proposed for the determination of antitumor drugs. For DNA sensor assembling, a glassy carbon electrode was modified with carbon black dispersed in DMF. After that, pillar [5]arene was adsorbed and Methylene blue and Neutral red were consecutively electropolymerized onto the carbon black layer. To increase sensitivity of intercalator detection, DNA was first mixed with water-soluble thiacalixarene bearing quaternary ammonium groups in the substituents at the lower rim. The deposition of the mixture on the electropolymerized dyes made it possible to detect doxorubicin as model intercalator by suppression of the redox activity of the polymerization products. The DNA sensor made it possible to determine 0.5 pM-1.0 nM doxorubicin (limit of detection 0.13 pM) with 20 min of incubation. The DNA sensor was successfully tested on spiked samples of human plasma and doxorubicin medication.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Impedimetric Aptasensors Based on Carbon Nanotubes - Poly(methylene blue) Composite
    Porfireva, Anna V.
    Evtugyn, Gennady A.
    Ivanov, Alexey N.
    Hianik, Tibor
    ELECTROANALYSIS, 2010, 22 (19) : 2187 - 2195
  • [2] Electrochemical DNA Sensor Based on Carbon BlackPoly(Neutral Red) Composite for Detection of Oxidative DNA Damage
    Kuzin, Yurii
    Kappo, Dominika
    Porfireva, Anna
    Shurpik, Dmitry
    Stoikov, Ivan
    Evtugyn, Gennady
    Hianik, Tibor
    SENSORS, 2018, 18 (10)
  • [3] Electrochemical Sensor Based on Poly(Methylene Blue) with Zinc Oxide Nanoparticles on Glassy Carbon Electrodes for Quantitative Determination of
    Abd-Alazize, Neam
    Al-Layla, Alaa M. T.
    EGYPTIAN JOURNAL OF CHEMISTRY, 2023, 66 (02): : 375 - 384
  • [4] Poly(neutral red)/Multi-walled Carbon Nanotube Composite Modified Electrochemical Sensor for Ratiometric Detection of Estriol
    Zhi-Yuan, Sun
    Wen-Fang, Fan
    Yong, Wang
    Qian-Fen, Zhuang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2023, 51 (01) : 42 - 52
  • [5] Lable-Free Electrochemical DNA Sensor Based on Gold Nanoparticles/Poly(neutral red) Modified Electrode
    Zhang, Keying
    Zhang, Yuzhong
    ELECTROANALYSIS, 2010, 22 (06) : 673 - 679
  • [6] Impedimetric DNA Sensor Based on Electrodes Modified with Carbon Nanotubes, Poly(Methylene Blue) and Aptamers toward Thrombin.
    Porfirieva, A. V.
    Evtyugin, G. A.
    Savelieva, M. A.
    Budnikov, H. C.
    UCHENYE ZAPISKI KAZANSKOGO UNIVERSITETA-SERIYA ESTESTVENNYE NAUKI, 2009, 151 (04): : 19 - 28
  • [7] Electrochemical Sensor Based on Poly(Azure B)-DNA Composite for Doxorubicin Determination
    Porfireva, Anna
    Vorobev, Vyatseslav
    Babkina, Sofya
    Evtugyn, Gennady
    SENSORS, 2019, 19 (09)
  • [8] Poly(Methylene Blue) Modified Carbon-based Electrodes for Electrochemical Detection of Hydrogen Sulfide
    Zlamalova, Magda
    Janda, Pavel
    Nesmerak, Karel
    XXXVI MODERNI ELEKTROCHEMICKE METODY, 2016, : 289 - 293
  • [9] Poly(methylene blue) modified electrode sensor for haemoglobin
    Brett, CMA
    Inzelt, G
    Kertesz, V
    ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) : 119 - 123
  • [10] Poly (4-vinylpyridine)/carbon black composite as a humidity sensor
    Li, Yang
    Hong, Lijie
    Chen, Yousi
    Wang, Huicai
    Lu, Xin
    Yang, Mujie
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 123 (01) : 554 - 559