Reproducibility of Optical Coherence Tomography Angiography Macular and Optic Nerve Head Vascular Density in Glaucoma and Healthy Eyes

被引:107
|
作者
Manalastas, Patricia I. C. [1 ,2 ]
Zangwill, Linda M. [1 ,2 ]
Saunders, Luke J. [1 ,2 ]
Mansouri, Kaweh [3 ,4 ]
Belghith, Akram [1 ,2 ]
Suh, Min Hee [1 ,2 ,5 ]
Yarmohammadi, Adeleh [1 ,2 ]
Penteado, Rafaella C. [1 ,2 ]
Akagi, Tadamichi [1 ,2 ,6 ]
Shoji, Takuhei [1 ,2 ,7 ]
Weinreb, Robert N. [1 ,2 ]
机构
[1] Univ Calif San Diego, Shiley Eye Inst, Hamilton Glaucoma Ctr, 9500 Gilman Dr 0946, San Diego, CA 92093 USA
[2] Univ Calif San Diego, Dept Ophthalmol, San Diego, CA 92103 USA
[3] Swiss Vis Network, Montchoisi Clin, Glaucoma Ctr, Lausanne, Switzerland
[4] Univ Colorado, Dept Ophthalmol, Denver, CO 80202 USA
[5] Inje Univ, Haeundae Paik Hosp, Busan, South Korea
[6] Kyoto Univ, Grad Sch Med, Dept Ophthalmol & Visual Sci, Kyoto, Japan
[7] Saitama Med Univ, Dept Ophthalmol, Iruma, Saitama, Japan
关键词
OCT angiography; OCT-A; reproducibility; vessel density; coefficient of variation; intraclass correlation; FIBER LAYER THICKNESS; LASER SPECKLE FLOWGRAPHY; VESSEL DENSITY; VISUAL-FIELD; BLOOD-FLOW; CHOROIDAL THICKNESS; DISC PERFUSION; STRATUS OCT; PERIPAPILLARY; RETINA;
D O I
10.1097/IJG.0000000000000768
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Optical coherence tomography angiography (OCT-A) is a noninvasive technology that allows visualization of retinal blood vessels. It is important to determine reproducibility of measurements as low precision can impair its diagnostic capabilities. The purpose of this study is to determine intravisit and intervisit reproducibility of optic nerve head (ONH) and macular vessel density measurements with OCT-A. Patients and Methods: Fifteen healthy volunteers and 14 glaucoma patients completed 2 OCT-A (AngioVue; Optovue Inc.) scanning sessions on each of 2 separate days to assess intravisit and intervisit reproducibility. A series of ONH and macula scans were acquired at each session. Vessel density (%), the proportion of vessel area over the total measurement area was calculated. Reproducibility was summarized using coefficients of variation (CV) and intraclass correlation coefficients calculated from variance component models. Results: In healthy eyes, the CV of intravisit and intervisit global vessel density measures ranged from 1.8% to 3.2% in ONH scans and 2.5% to 9.0% in macular scans. In glaucoma eyes, the CV of intravisit and intervisit global vessel density measures ranged from 2.3% to 4.1% in ONH scans and 3.2% to 7.9% in macular scans. CVs were lower for global than sectorial measures. Global OCT-A ONH intraclass correlation measurements for the retinal nerve fiber layer in healthy eyes were lower (range: 0.65 to 0.85) than in glaucoma eyes (range: 0.89 to 0.94). Scan size did not make large differences in measurement CVs. Conclusions: Reproducibility of OCT-A ONH and macula vessel density measurements is good. Moreover, glaucoma patients have sparser vessel density with poorer reproducibility than healthy subjects.
引用
收藏
页码:851 / 859
页数:9
相关论文
共 50 条
  • [1] Evaluation of macular and optic nerve head changes by optical coherence tomography angiography in glaucomatous eyes
    Mohamed, Ezzeldin G.
    Elsersy, Tamer H.
    Lotfy, Ayman M.
    Elshabrawy, Ahmed M.
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2024, 117 (04) : 292 - 305
  • [2] Reproducibility of macular and optic nerve head vessel density measurements by swept-source optical coherence tomography angiography
    Fernandez-Vigo, Jose Ignacio
    Kudsieh, Bachar
    Macarro-Merino, Ana
    Arriola-Villalobos, Pedro
    Martinez-de-la-Casa, Jose Maria
    Garcia-Feijoo, Julian
    Fernandez-Vigo, Jose Angel
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2020, 30 (04) : 756 - 763
  • [3] Optical Coherence Tomography Angiography of Optic Disc and Macula Vessel Density in Glaucoma and Healthy Eyes
    Yip, Vivien C. H.
    Wong, Hon Tym
    Yong, Vernon K. Y.
    Lim, Boon Ang
    Hee, Owen K.
    Cheng, Jun
    Fu, Huazhu
    Lim, Chingwei
    Tay, Elton L. T.
    Loo-Valdez, Roselyn G.
    Teo, Hwei Yee
    Lim, Angela P. H.
    Yip, Leonard W. L.
    JOURNAL OF GLAUCOMA, 2019, 28 (01) : 80 - 87
  • [4] Optical Coherence Tomography Angiography of Optic Disc and Macula Vessel Density in Glaucoma and Healthy Eyes
    Jain, Kanika
    Pegu, Julie
    Bhoot, Madhu
    Dubey, Suneeta
    JOURNAL OF GLAUCOMA, 2019, 28 (07) : E131 - E132
  • [5] Repeatability of Macular and Optic Nerve Head Measurements by Optical Coherence Tomography Angiography in Healthy Children
    Perez-Garcia, Pilar
    Morales-Fernandez, Laura
    Fernandez-Vigo, Jose Ignacio
    Saenz-Frances, Federico
    Burgos-Blasco, Barbara
    Guemes-Villahoz, Noemi
    Oribio-Quinto, Carlos
    Garcia-Feijoo, Julian
    Martinez-de-la-Casa, Jose Maria
    CURRENT EYE RESEARCH, 2021, 46 (10) : 1574 - 1580
  • [6] Response: Optical Coherence Tomography Angiography of Optic Disc and Macula Vessel Density in Glaucoma and Healthy Eyes
    Yip, Vivien C. H.
    Wong, Hon Tym
    Yong, Vernon K. Y.
    Lim, Boon-Ang
    Hee, Owen K.
    Cheng, Jun
    Fu, Huazhu
    Lim, Ching-Wei
    Tay, Elton L. T.
    Loo-Valdez, Roselyn G.
    Teo, Hwei-Yee
    Lim, Angela P. H.
    Yip, Leonard W. L.
    JOURNAL OF GLAUCOMA, 2019, 28 (07) : E132 - E133
  • [7] Optical Coherence Tomography Angiography Vessel Density in Healthy, Glaucoma Suspect, and Glaucoma Eyes
    Belbase, Umesh
    Maharjan, Indra Man
    Subedi, Anup
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2024, 36 (01): : 31 - 36
  • [8] Optical Coherence Tomography Angiography Vessel Density in Healthy, Glaucoma Suspect, and Glaucoma Eyes
    Yarmohammadi, Adeleh
    Zangwill, Linda M.
    Diniz-Filho, Alberto
    Suh, Min Hee
    Manalastas, Patricia Isabel
    Fatehee, Naeem
    Yousefi, Siamak
    Belghith, Akram
    Saunders, Luke J.
    Medeiros, Felipe A.
    Huang, David
    Weinreb, Robert N.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (09) : OCT451 - OCT459
  • [9] Repeatability and reproducibility of optic nerve head optical coherence tomography angiography (OCTA) measurements on glaucomatous and normal eyes
    Di, Lung
    Yu, Sophia
    Sha, Patricia
    Severin, Todd
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [10] Vascular density of optic nerve head in diabetic retinopathy using optical coherence tomography angiography
    Ghassemi, Fariba
    Berijani, Sahar
    Roohipoor, Ramak
    Mohebbi, Masoumeh
    Babeli, Ameneh
    Gholizadeh, Alireza
    Sabour, Siamak
    INTERNATIONAL JOURNAL OF RETINA AND VITREOUS, 2020, 6 (01)