Twenty-five-year experience with the Medtronic-Hall valve prosthesis in the aortic position - A follow-up cohort study of 816 consecutive patients

被引:31
|
作者
Svennevig, Jan L.
Abdelnoor, Michel
Nitter-Hauge, Sigurd
机构
[1] Univ Oslo, Rikshosp, Dept Thorac & Cardiovasc Surg, Radiumhosp Med Ctr, N-0027 Oslo, Norway
[2] Univ Oslo, Rikshosp, Dept Cardiol, Radiumhosp Med Ctr, N-0027 Oslo, Norway
关键词
heart diseases; prosthesis; heart valves;
D O I
10.1161/CIRCULATIONAHA.106.677773
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The Medtronic-Hall valve was developed and for the first time implanted in Oslo, Norway, in 1977. A total of 1104 patients received this valve at Rikshospitalet from 1977 to 1987. In the present study, we followed up on all 8 16 patients undergoin g aortic valve replacement over a 25-year period. Methods and Results - This is a retrospective cohort analysis of 816 consecutive patients undergoing aortic valve replacement with the Medtronic-Hall valve at Rikshospitalet, Oslo, Norway, from 1977 to 1987. All patients were contacted by ineans of questionnaires or telephone. Data were checked against hospital databases and medical records. Date of death was verified by the Norwegian civil registry. Follow-up was 99.6% complete. Survival analysis included operative deaths as well as late deaths. Survival at 25 years was 24.9%. No mechanical failures were found. Valve thrombosis was seen in 4 patients, in 1 case combined with pannus formation. Small valves (20 turn to 21 mm) were associated with reduced survival; however, when controlled for the confounding effects of age and gender, valve size did not remain a significant risk factor. Patient-related factors were important: Older age, female gender, and the need for concomitant coronary artery bypass surgery significantly reduced survival, whereas surgery of the ascending aorta did not. Linearized rates of thromboembolic complications, warfarin-related bleeding, and endocarditis were 1.5%, 0.7%, and 0. 16%/patient-year, respectively. At follow-up, 79% of the patients were in New York Heart Association classes I to II. Conclusions - This study confirms the excellent long-term outcorne for patients with Medtronic-Hall valves in the aortic position.
引用
收藏
页码:1795 / 1800
页数:6
相关论文
共 50 条
  • [1] Fifteen-year experience with the Medtronic-Hall valve prosthesis - A follow-up study of 1104 consecutive patients
    NitterHauge, S
    Abdelnoor, M
    Svennevig, JL
    CIRCULATION, 1996, 94 (09) : 105 - 108
  • [2] A 5-YEAR FOLLOW-UP OF THE MEDTRONIC-HALL VALVE - SURVIVAL AND THROMBOEMBOLISM
    SEMB, BKH
    HALL, KV
    NITTERHAUGE, S
    ABDELNOOR, M
    THORACIC AND CARDIOVASCULAR SURGEON, 1983, 31 : 61 - 65
  • [3] CLINICAL AND SURVIVAL-DATA OF A - 5 YEARS FOLLOW-UP OF PATIENTS WITH THE MEDTRONIC-HALL DISK VALVE PROSTHESIS
    NITTERHAUGE, S
    SEMB, B
    ABDELNOOR, M
    HALL, KV
    CIRCULATION, 1982, 66 (04) : 274 - 274
  • [4] PROGNOSTIC VARIABLES IN LATE FOLLOW-UP OF AORTIC-VALVE REPLACEMENT USING THE PROPORTIONAL HAZARD MODEL - A STUDY ON PATIENTS USING THE MEDTRONIC-HALL CARDIAC PROSTHESIS
    ABDELNOOR, M
    HAUGE, SN
    HALL, KV
    LIFE SUPPORT SYSTEMS, 1986, 4 (02): : 103 - 113
  • [5] Long term follow-up of small (Size 20 and 21) medtronic-hall aortic valve prostheses
    Obadia, JF
    Martelloni, YA
    Bastien, OH
    deGevigney, GMD
    Chassignolle, JF
    ANNALS OF THORACIC SURGERY, 1997, 64 (02): : 421 - 425
  • [6] A retrospective comparative study of aortic valve replacement with St. Jude Medical and Medtronic-Hall prostheses:: A 20-year follow-up study
    Anttila, V
    Heikkinen, J
    Biancari, F
    Oikari, K
    Pokela, R
    Lepojärvi, M
    Salmela, E
    Juvonen, T
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2002, 36 (01) : 53 - 59
  • [7] COMPOSITE GRAFT (MEDTRONIC-HALL) REPLACEMENT OF THE ASCENDING AORTA AND AORTIC-VALVE IN AORTIC-ANEURYSMS - WHAT IS ADEQUATE FOLLOW-UP
    PRACKI, P
    PETRI, D
    KELLNER, HJ
    STRUCK, E
    THORACIC AND CARDIOVASCULAR SURGEON, 1995, 43 (02): : 104 - 107
  • [8] Twenty-five-year follow-up evaluation of an active silicone/Dacron tendon interposition prosthesis: A case report
    Ketchum, LD
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2000, 25A (04): : 731 - 733
  • [9] Cigarette smoking and mortality risk - Twenty-five-year follow-up of the seven countries study
    Jacobs, DR
    Adachi, H
    Mulder, I
    Kromhout, D
    Menotti, A
    Nissinen, A
    Blackburn, H
    ARCHIVES OF INTERNAL MEDICINE, 1999, 159 (07) : 733 - 740
  • [10] The continuity of conflict and compromise formation from infancy to adulthood: A twenty-five-year follow-up study
    McDevitt, JB
    JOURNAL OF THE AMERICAN PSYCHOANALYTIC ASSOCIATION, 1997, 45 (01) : 105 - 126