Continuous noninvasive hemoglobin monitoring: ready for prime time?

被引:8
|
作者
Suehiro, Koichi [1 ]
Joosten, Alexandre [1 ]
Alexander, Brenton [1 ]
Cannesson, Maxime [1 ]
机构
[1] Univ Calif Irvine, Dept Anesthesiol & Perioperat Care, Orange, CA 92868 USA
关键词
accuracy; bleeding; hemoglobin; noninvasive; transfusion; PULSE CO-OXIMETRY; ACCURACY; TRANSFUSION; COOXIMETER; PRECISION; HEMOCUE; RISK; CELL;
D O I
10.1097/MCC.0000000000000197
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose of review Determination of hemoglobin (Hb) concentration is essential for the detection of anemia and hemorrhage and is widely used to evaluate a patient for a possible blood transfusion. Although commonly accepted as intrinsic to the process, traditional laboratory measurements of Hb are invasive, intermittent, and time-consuming. Noninvasive Hb (NIHb)-monitoring devices have recently become available and promise the potential for detecting sudden changes in a patient's Hb level. In addition to reduced delays in clinical intervention, these devices also allow for a reduction in patient discomfort, infection risk, required personnel, and long-term costs. Unfortunately, it has been shown that many clinical factors can influence their accuracy. Recent findings Many studies have been published on the accuracy and precision of NIHb-monitoring devices in various clinical settings. A recent meta-analysis has shown a small mean difference but wide limits of agreement between NIHb and laboratory measurements, indicating that caution should be used by physicians when making clinical decisions based on this device. Summary NIHb measurements may currently be considered to be a supplemental tool for monitoring trends in Hb concentration, but are not currently developed enough to replace an invasive approach. Moreover, further studies are still required before implementing NIHb in the clinical decision-making process. Specifically, no studies have demonstrated that this technology improves clinical outcomes or patient safety.
引用
收藏
页码:265 / 270
页数:6
相关论文
共 50 条
  • [1] Continuous Noninvasive Hemoglobin Monitor from Pulse Ox: Ready for Prime Time?
    Bellal Joseph
    Pantelis Hadjizacharia
    Hassan Aziz
    Kara Snyder
    Julie Wynne
    Narong Kulvatunyou
    Andrew Tang
    Terence O’Keeffe
    Rifat Latifi
    Randall Friese
    Peter Rhee
    World Journal of Surgery, 2013, 37 : 525 - 529
  • [2] Continuous Noninvasive Hemoglobin Monitor from Pulse Ox: Ready for Prime Time?
    Joseph, Bellal
    Hadjizacharia, Pantelis
    Aziz, Hassan
    Snyder, Kara
    Wynne, Julie
    Kulvatunyou, Narong
    Tang, Andrew
    O'Keeffe, Terence
    Latifi, Rifat
    Friese, Randall
    Rhee, Peter
    WORLD JOURNAL OF SURGERY, 2013, 37 (03) : 525 - 529
  • [3] Continuous EEG monitoring: is it ready for prime time?
    Kurtz, Pedro
    Hanafy, Khalid A.
    Claassen, Jan
    CURRENT OPINION IN CRITICAL CARE, 2009, 15 (02) : 99 - 109
  • [4] Understanding Noninvasive and Continuous Hemoglobin Monitoring
    O'Reilly, Michael
    CRITICAL CARE MEDICINE, 2013, 41 (05) : E52 - E52
  • [5] Noninvasive Electrocardiographic Mapping: Are We Ready for Prime Time?
    Aryana, Arash
    O'Neill, Padraig Gearoid
    d'Avila, Andre
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2015, 4 (10):
  • [6] On rendering continuous glucose monitoring ready for prime time in the cardiac care unit
    Rowen, Michaelanne
    Schneider, David J.
    Pratley, Richard E.
    Sobel, Burton E.
    CORONARY ARTERY DISEASE, 2007, 18 (05) : 405 - 409
  • [7] Understanding Noninvasive and Continuous Hemoglobin Monitoring reply
    Ouattara, Alexandre
    CRITICAL CARE MEDICINE, 2013, 41 (05) : E53 - E53
  • [8] Continuous speech recognition: Ready for prime time?
    Finley, S
    TOWARD AN ELECTRONIC PATIENT RECORD '98 CONFERENCE AND EXPOSITION, PROCEEDINGS - VOLS 1-3, 1998, : A335 - A337
  • [9] Noninvasive prenatal testing for aneuploidy-ready for prime time?
    Chitty, Lyn S.
    Hill, Melissa
    White, Helen
    Wright, David
    Morris, Stephen
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2012, 206 (04) : 269 - 275
  • [10] Noninvasive Tools to Assess Hepatic Fibrosis: Ready for Prime Time?
    Schmeltzer, Paul A.
    Talwalkar, Jayant A.
    GASTROENTEROLOGY CLINICS OF NORTH AMERICA, 2011, 40 (03) : 507 - +