Glaucoma Associated With Boston Type I Keratoprosthesis

被引:85
|
作者
Kamyar, Roheena [1 ]
Weizer, Jennifer S. [1 ]
de Paula, Fernando Heitor [1 ,2 ]
Stein, Joshua D. [1 ]
Moroi, Sayoko E. [1 ]
John, Denise [1 ]
Musch, David C. [1 ,3 ]
Mian, Shahzad I. [1 ]
机构
[1] Univ Michigan, Sch Med, Dept Ophthalmol & Visual Sci, WK Kellogg Eye Ctr, Ann Arbor, MI 48105 USA
[2] Dept Ophthalmol, Div Cornea & External Dis, Sao Paulo, Brazil
[3] Univ Michigan, Sch Publ Hlth, Dept Epidemiol, Ann Arbor, MI 48105 USA
关键词
Boston type I keratoprosthesis; glaucoma; keratoplasty; PENETRATING KERATOPLASTY; COMPLICATIONS;
D O I
10.1097/ICO.0b013e31820f7a32
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate outcomes of the Boston type I keratoprosthesis (KPro) and associated incidence of glaucoma. Design: Retrospective cohort study. Participants: All patients who underwent KPro surgery at 1 institution from 2003 to 2009 with at least 3 months of follow-up. Methods: Preoperative visual acuity, diagnosis, history of glaucoma, and intraoperative and postoperative parameters were recorded. Statistical analysis was performed to identify factors that may influence increase in intraocular pressure (IOP) and glaucoma development or progression after surgery. Main Outcome Measures: Best-corrected visual acuity (BCVA), IOP, postoperative medical and surgical treatments for glaucoma, and KPro retention and complications. Results: Thirty-six KPro procedures were performed in 30 eyes of 29 patients with a mean (+/- SD) follow-up of 17 +/- 19 months (range, 3-67 months). The main indication for KPro implantation was corneal graft failure (77%). Primary KPro procedures were performed in 23% of eyes for limbal stem cell deficiency secondary to chemical burns and aniridia and for herpetic disease. Median preoperative BCVA was hand motions with an overall improvement to 20/330 (range, 20/20 to hand motions) at 9 months postoperatively; mean BCVA was 20/600 (range, 20/40 to NLP) at the last follow-up. Twenty eyes (67%) had a preoperative history of glaucoma, with 8 of those eyes (40%) having undergone previous glaucoma surgery. Twenty-one eyes (70%) underwent concomitant glaucoma surgery. Postoperative increased IOP (22 mm Hg or higher) was noted in 15 eyes (50%), although definite glaucoma development or progression was noted in 7 of those 15 eyes (23% of total eyes). Mean BCVA at the last follow-up in eyes with glaucoma development or progression was 3/200 compared with 20/563 in the remaining 23 eyes. Six patients (20%) required repeat KPro implantation, and retroprosthetic membranes developed in 23 eyes (77%). No patient had vitritis or infectious endophthalmitis develop. Conclusions: The Boston type I KPro is an effective option for management of eyes with poor prognosis for primary or repeat penetrating keratoplasty. Visual potential is limited by preoperative comorbidities; however, glaucoma development or progression of preexisting glaucoma is a significant cause of postoperative visual loss. Rigorous perioperative management of elevated IOP is essential for long-term success of KPro surgery.
引用
收藏
页码:134 / 139
页数:6
相关论文
共 50 条
  • [1] Glaucoma management in Boston keratoprosthesis type I recipients
    Pho Nguyen
    Chopra, Vikas
    CURRENT OPINION IN OPHTHALMOLOGY, 2014, 25 (02) : 134 - 140
  • [2] Challenges of Glaucoma Management in Patients with Type I Boston Keratoprosthesis
    AlHilali, Sara M.
    Al-Swailem, Samar A.
    CLINICAL OPHTHALMOLOGY, 2022, 16 : 369 - 374
  • [3] Postoperative outcome in eyes with glaucoma treated with the Boston type I keratoprosthesis
    Romero, Pablo
    Chen, Philip P.
    Shen, Tueng T.
    Slabaugh, Mark A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [4] Boston type I keratoprosthesis
    Hu, Karen
    Tarib, Imane
    Cortina, Maria Soledad
    ANNALS OF EYE SCIENCE, 2024, 9
  • [5] Glaucoma Implants for the Control of Intraocular Pressure With Type I Boston Keratoprosthesis
    Wong, J. J.
    Vajaranant, T. S.
    Wilensky, J. T.
    de la Cruz, J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [6] Complications associated with Boston keratoprosthesis type 1 and glaucoma drainage devices
    Robert, Marie-Claude
    Pomerleau, Valerie
    Harissi-Dagher, Mona
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2013, 97 (05) : 573 - 577
  • [7] Management of glaucoma with Boston type 1 keratoprosthesis
    Utine, Canan Asli
    Arikan, Gul
    Yardim, Elvan
    Gunenc, Uzeyir
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2023, 86 (02) : 137 - 144
  • [8] Management of glaucoma with Boston type 1 keratoprosthesis
    Bhambra, Nishaant
    Harissi-Dagher, Mona
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2022, 85 (05) : 540 - 542
  • [9] Safety of Concurrent Boston Type I Keratoprosthesis and Glaucoma Drainage Device Implantation
    Lenis, Tamara L.
    Chiu, Stephan Y.
    Law, Simon K.
    Yu, Fei
    Aldave, Anthony J.
    OPHTHALMOLOGY, 2017, 124 (01) : 12 - 19
  • [10] Visual Field Characteristics of Type I Boston Keratoprosthesis Patients Without Glaucoma
    Quercia, Andressa Z. F.
    Silva, Luzia D.
    de Oliveira, Filipe
    Teixeira, Sergio H.
    de Sousa, Luciene B.
    de Oliveira, Lauro A.
    JOURNAL OF GLAUCOMA, 2021, 30 (06) : 532 - 536