Energy-saving potential of an indirect evaporative cooler

被引:112
|
作者
Maheshwari, GP [1 ]
Al-Ragom, F [1 ]
Suri, RK [1 ]
机构
[1] Kuwait Inst Sci Res, Dept Energy, Safat 13109, Kuwait
关键词
indirect evaporative cooler; pre-cooling of ventilation air;
D O I
10.1016/S0306-2619(00)00066-0
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In many parts of the world, large differences between the dry-bulb and wet-bulb temperatures during the summer season can be used advantageously to pre-cool fresh air for air-conditioned space using an indirect evaporative cooler (IEC). This paper presents an analytical evaluation using the field performance results of a 1180 L/s (2500 ft(3)/min) IEC unit and the recorded weather data in coastal and interior locations in Kuwait. Estimated cooling capacity of the IEC is 3.1 and 2.3 tons of refrigeration (RT, 1 RT = 3.517 kW of heat absorption), for the interior and the coastal areas, respectively. Furthermore, the power requirements of a conventional packaged unit air-conditioner (PU) to produce this cooling in these respective areas are 4.93 and 3.85 kW compared with only 1.11 kW needed by the IEC. Also, the seasonal energy savings of the IEC are 12,418 and 6320 kWh, for the interior and coastal areas, respectively. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:69 / 76
页数:8
相关论文
共 50 条
  • [1] Energy saving potential of indirect evaporative cooler under Indian climates
    Jain, J. K.
    Hindoliya, D. A.
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2016, 11 (02) : 193 - 198
  • [2] Studies on the evaporative pad cooler characteristics of energy-saving and environment protection
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 1997, 13 (03): : 197 - 202
  • [3] Simplified predicting models on Energy-saving Potential of Indirect Evaporative Coolers in Hong Kong
    Min Yunran
    Chen Yi
    Yang Hongxing
    RENEWABLE ENERGY INTEGRATION WITH MINI/MICROGRID, 2019, 159 : 225 - 230
  • [4] Research and Design of Energy-saving and Environmental-protection Full Evaporative Air Cooler
    Shang Li Xin
    Zhou Chuan Yi
    Jing Yun Tao
    FRONTIERS OF GREEN BUILDING, MATERIALS AND CIVIL ENGINEERING III, PTS 1-3, 2013, 368-370 : 400 - +
  • [5] Energy saving potential of an indirect evaporative cooler as a pre-cooling unit for mechanical cooling systems in Iran
    Delfani, Shahram
    Esmaeelian, Jafar
    Pasdarshahri, Hadi
    Karami, Maryam
    ENERGY AND BUILDINGS, 2010, 42 (11) : 2169 - 2176
  • [6] Energy-saving design of shower cooler
    Hefei Univ of Technology, Hefei, China
    Shiyou Huagong, 8 (553-556):
  • [7] Recent researches in indirect evaporative cooler - III: Optimization of the cooling potential of a room-coupled indirect evaporative cooler
    Tulsidasani, TR
    Sawhney, RL
    Singh, SP
    Sodha, MS
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1998, 22 (08) : 741 - 750
  • [8] An energy-saving ceramic cooler for hot arid regions
    Aimiuwu, Victor O.
    PROCEEDINGS OF THE NATIONAL SOCIETY OF BLACK PHYSICISTS, 2008, 991 : 75 - 81
  • [9] System for saving energy in a climate control evaporative air cooler
    Arturo Ramirez-Sanchez, Fernando
    Antonio Arjona-Lopez, Marco
    DYNA, 2016, 91 (03): : 257 - 262
  • [10] Comparative study of two different evaporative systems:: an indirect evaporative cooler and a semi-indirect ceramic evaporative cooler
    Martínez, FJR
    Gómez, EV
    Martín, RH
    Gutiérrez, JM
    Diez, FV
    ENERGY AND BUILDINGS, 2004, 36 (07) : 696 - 708