Movement of the upper cervical spine during laryngoscopy: a comparison of the Bonfils intubation fibrescope and the Macintosh laryngoscope

被引:56
|
作者
Rudolph, C
Schneider, JP
Wallenborn, J
Schaffranietz, L
机构
[1] Leipzig Univ Hosp, Dept Anaesthesiol & Intens Care Med, D-04103 Leipzig, Germany
[2] Leipzig Univ Hosp, Dept Diagnost Radiol, D-04103 Leipzig, Germany
关键词
D O I
10.1111/j.1365-2044.2005.04224.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The movements of the upper cervical spine were measured by fluoroscopy in 20 patients during laryngoscopy with the Bonfils intubation fibrescope and the Macintosh laryngoscope. Laryngoscopy with both the Bonfils intubation fibrescope and the Macintosh laryngoscope resulted in significant extension of the cervical spine as compared to the neutral position but this extension was significantly less with the Bonfils intubation fibrescope than with the Macintosh (p = 0.001). However, the atlanto-occipital distance was significantly greater during laryngoscopy with the Bonfils intubation fibrescope (p = 0.002), and the angle between the occiput and C1 differed significantly between the two techniques (p = 0.001). With the Bonfils intubation fibrescope, significantly less extension was also found at the C1/C2 and C3/C4 levels (p = 0.001 and p = 0.049, respectively). There is therefore significantly less movement of the upper cervical spine during laryngoscopy with the Bonfils fibrescope compared with the Macintosh laryngoscope.
引用
收藏
页码:668 / 672
页数:5
相关论文
共 50 条
  • [1] Upper cervical spine movement during intubation: fluoroscopic comparison of the AirWay Scope, McCoy laryngoscope, and Macintosh laryngoscope
    Maruyama, K.
    Yamada, T.
    Kawakami, R.
    Kamata, T.
    Yokochi, M.
    Hara, K.
    BRITISH JOURNAL OF ANAESTHESIA, 2008, 100 (01) : 120 - 124
  • [2] Bonfils intubation fibrescope: Use in simulation-based intubation training for medical students in comparison to MacIntosh laryngoscope
    Limbach T.
    Ott T.
    Griesinger J.
    Jahn-Eimermacher A.
    Piepho T.
    BMC Research Notes, 9 (1)
  • [3] Cervical spine movements during laryngoscopy - Comparison of the Macintosh and McCoy laryngoscope blades
    MacIntyre, PA
    McLeod, ADM
    Hurley, R
    Peacock, C
    ANAESTHESIA, 1999, 54 (05) : 413 - 418
  • [4] Cervical spine movement during laryngoscopy using the Airway Scope compared with the Macintosh laryngoscope
    Hirabayashi, Y.
    Fujita, A.
    Seo, N.
    Sugimoto, H.
    ANAESTHESIA, 2007, 62 (10) : 1050 - 1055
  • [5] Three-dimensional cervical spine movement during intubation using the Macintosh and BullardTM laryngoscopes, the bonfils fibrescope and the intubating laryngeal mask airway
    Wahlen, BM
    Gercek, E
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 (11) : 907 - 913
  • [6] Comparison of the bonfils fibrescope and bullard laryngoscope
    Quoc Nguyen
    Kevin Armstrong
    Canadian Journal of Anesthesia, 2006, 53 (Suppl 1): : 26464 - 26464
  • [7] A comparison of cervical spine movement during laryngoscopy using the Airtraq® or Macintosh laryngoscopes
    Hirabayashi, Y.
    Fujita, A.
    Seo, N.
    Sugimoto, H.
    ANAESTHESIA, 2008, 63 (06) : 635 - 640
  • [8] Tracheal intubation using the Bonfils intubation fibrescope after failed direct laryngoscopy
    Bein, B
    Yan, M
    Tonner, PH
    Scholz, J
    Steinfath, M
    Dörges, V
    ANAESTHESIA, 2004, 59 (12) : 1207 - 1209
  • [9] Cervical spine motion: A fluoroscopic comparison during intubation with lighted stylet, GlideScope, and Macintosh laryngoscope
    Turkstra, TP
    Craen, RA
    Pelz, DM
    Gelb, AW
    ANESTHESIA AND ANALGESIA, 2005, 101 (03): : 910 - 915
  • [10] Intubation Biomechanics Laryngoscope Force and Cervical Spine Motion during Intubation with Macintosh and Airtraq Laryngoscopes
    Hindman, Bradley J.
    Santoni, Brandon G.
    Puttlitz, Christian M.
    From, Robert P.
    Todd, Michael M.
    ANESTHESIOLOGY, 2014, 121 (02) : 260 - 271