A microvolumetric blood counter/sampler for metabolic PET studies in small animals

被引:21
|
作者
Lapointe, D [1 ]
Cadorette, J [1 ]
Rodrigue, S [1 ]
Rouleau, D [1 ]
Lecomte, R [1 ]
机构
[1] Univ Sherbrooke, Metab & Funct Imaging Ctr, Dept Med Nucl & Radiobiol, Sherbrooke, PQ J1H 5N4, Canada
关键词
D O I
10.1109/23.708343
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Quantitative metabolic imaging in small animals with positron emission tomography (PET) requires the determination of the tracer concentration in whole blood, arterial plasma and metabolites as a function of time, A blood counting and sampling system was designed to simultaneously measure the time-activity curve as microvolumes of blood are collected. The system consists of a flow-through counter made of a plastic scintillator to detect positrons and of a computer-controlled blood sampler based on the concept of bubble segmentation. The number and size of samples, the withdrawal speed and the sampling time are programmable and can be modified on-line. Samples as small as 10 mu l can be repetitively obtained from an implanted arterial catheter in the femoral vein or artery of small rats (150 g) or the jugular vein of mice (20 g). For medium sampling speed (100 mu l/min) at a constant rate, the standard deviation of the sample activity is typically less than 1%. By cutting the tubing at the bubbles at the end of the experiment, samples are made available for further processing and biochemical analysis. This apparatus has become an essential tool for quantitative animal PET studies, allowing easy, reliable sampling at a low cost.
引用
收藏
页码:2195 / 2199
页数:5
相关论文
共 50 条
  • [1] A microvolumetric β blood counter for pharmacokinetic PET studies in small animals
    Convert, L.
    Morin-Brassard, G.
    Cadorette, J.
    Rouleau, D.
    Croteau, E.
    Archambault, M.
    Fontaine, R.
    Lecomte, R.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2674 - 2678
  • [2] A microvolumetric β blood counter for pharmacokinetic PET studies in small animals
    Convert, L.
    Morin-Brassard, G.
    Cadorette, J.
    Rouleau, D.
    Croteau, E.
    Archambault, M.
    Fontaine, R.
    Lecomte, R.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (01) : 173 - 180
  • [3] Microvolumetric blood sampler for small animal PET studies.
    Lapointe, D
    Cadorette, J
    Rodrigue, S
    Lecomte, R
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 877 - 877
  • [4] Design of a microvolumetric blood counter/sampler for metabolic PET imaging in rats and mice
    Lapointe, D
    Cadorette, J
    Rodrigue, S
    Rouleau, D
    Lecomte, R
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1399 - 1403
  • [5] USE OF A WHOLE BODY COUNTER FOR METABOLIC STUDIES IN SMALL LABORATORY ANIMALS (RATS)
    PAVLIK, L
    BABICKY, A
    PARIZEK, J
    PHYSIOLOGIA BOHEMOSLOVACA, 1969, 18 (5-6): : 502 - &
  • [6] A new tool for molecular imaging:: The microvolumetric β blood counter
    Convert, Laurence
    Morin-Brassard, Guillaume
    Cadorette, Jules
    Archambault, Melanie
    Bentourkia, M'hamed
    Lecomte, Roger
    JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (07) : 1197 - 1206
  • [7] Automatic Control System of a Microfluidic Blood Sampler for Quantitative microPET Studies in Small Laboratory Animals
    Lin, Hong-Dun
    Sui, Guodong
    Lee, Cheng-Chung
    Silverman, Robert W.
    Cole, Graham
    Leong, Joel
    Huang, Sung-Cheng
    Phelps, Michael E.
    Wu, Hsiao-Ming
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2095 - 2098
  • [8] BLOOD PRESSURE STUDIES IN SMALL ANIMALS
    Woodbury, R. A.
    Hamilton, W. F.
    AMERICAN JOURNAL OF PHYSIOLOGY, 1937, 119 (04): : 663 - 674
  • [9] MR-compatible blood sampler for PET
    Breuer, J.
    Grazioso, R.
    Corbeil, J.
    Zhang, N.
    Schmand, M.
    Wienhard, K.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3426 - +
  • [10] ENVIRONMENTAL CHAMBER SYSTEM FOR PROLONGED METABOLIC STUDIES ON SMALL ANIMALS
    JORDAN, JP
    HUSTON, LJ
    SIMMONS, JB
    CLARKSON, DP
    MARTZ, WW
    SCHATTE, CL
    SPACE LIFE SCIENCES, 1973, 4 (3-4): : 424 - 433