GUIDED WAVE DAMAGE DETECTION IN POWER-PLANT-TUBES BY USING MAGNETOSTRICTIVE TRANSDUCER ARRAYS

被引:0
|
作者
Guo, Peng [1 ]
Li, Hongyuan [1 ]
Tian, Zhenhua [2 ]
Xu, Hong [1 ]
机构
[1] North China Elect Power Univ, Sch Energy Power & Mech Engn, Beijing 102206, Peoples R China
[2] Univ South Carolina, Dept Mech Engn, Columbia, SC 29208 USA
关键词
MODE; TECHNOLOGY; REFLECTION;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper presents an efficient damage detection technique for power-plant-tubes by using guided waves and magnetostrictive transducer arrays. Particularly, our detection technique focuses on the small diameter and thick wall power plant-tubes, such as superheater tubes, reheater tubes and water wall tubes. Firstly, the damage effects on guided waves in small diameter and thick wall tubes were studied by using three-dimensional finite element method. The wave reflections and mode conversions induced by damage were investigated. Secondly, based on T (0, 1)-F (n, 2) modes, magnetostrictive transducers were designed for guided wave generation and sensing in small diameter and thick wall tubes. The designed magnetostrictive transducers can effectively generate and measure guided waves, especially the non-dispersive torsional T (0, 1) wave mode. Finally, a magnetostrictive transducer array was developed for damage detection in small diameter and thick wall tubes. Through a virtual focusing array imaging algorithm, intensity images were constructed, which can show both the location and size of damage.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Development of in -bore magnetostrictive transducer for ultrasonic guided wave based -inspection of steam generator tubes of PFBR
    Narayanan, M. M.
    Arjun, V.
    Kumar, Anish
    Mukhopadhyay, C. K.
    ULTRASONICS, 2020, 106
  • [2] Guided wave based cable damage detection using magneto-strictive transducer
    Sui, X. D.
    Duan, Y. F.
    Yun, C. B.
    Tang, Z. F.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT, LIFE-CYCLE SUSTAINABILITY AND INNOVATIONS, 2021, : 3925 - 3930
  • [3] Experimental research on new magnetostrictive longitudinal guided wave transducer
    Shen Lihua
    Wang Yuemin
    Sun Fengrui
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 3421 - 3424
  • [4] Experimental Evidence and Analysis of a Mode Conversion of Guided Wave Using Magnetostrictive Strip Transducer
    Cheong, Yong-Moo
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2009, 29 (02) : 93 - 97
  • [5] Design of the Magnetostrictive Transducer for the Boiler Tube in Power Plant
    Song Xiaochun
    Yu Hao
    Yang Lin
    ISTM/2009: 8TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, 2009, : 1964 - 1968
  • [6] Magnetostrictive Guided Wave Transducer with Semicircular Structure for Defect Detection of Semi-Exposed Pipe
    Linhao Wang
    Jiang Xu
    Chaoyue Hu
    Journal of Nondestructive Evaluation, 2021, 40
  • [7] Design of the Magnetostrictive Transducer for the Boiler Tube in Power Plant
    Song Xiaochun
    Yu Hao
    Yang Lin
    ISTM/2009: 8TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, 2009, : 2059 - 2063
  • [8] Magnetostrictive Guided Wave Transducer with Semicircular Structure for Defect Detection of Semi-Exposed Pipe
    Wang, Linhao
    Xu, Jiang
    Hu, Chaoyue
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2021, 40 (04)
  • [9] Application of magnetostrictive transducer for the long-range guided wave inspection
    Cheong, Yong-Moo
    Kim, Shin
    Jung, Hyun-Kyu
    MECHANICAL BEHAVIOR OF MATERIALS X, PTS 1AND 2, 2007, 345-346 : 1295 - +
  • [10] Megahertz-Range Guided Pure Torsional Wave Transduction and Experiments Using a Magnetostrictive Transducer
    Cho, Seung Hyun
    Kim, Hoe Woong
    Kim, Yoon Young
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (05) : 1225 - 1229