Dual-emission ratiometric fluorescence detection of aspirin in human saliva: onsite naked-eye detection and high stability

被引:11
|
作者
Chen, Li [1 ]
Sun, Lin [1 ]
Zheng, Jiahong [1 ,2 ]
Dai, Jiangdong [1 ]
Wu, Yilin [1 ]
Dai, Xiaohui [1 ]
Li, Chunxiang [1 ]
Yan, Yongsheng [1 ]
机构
[1] Jiangsu Univ, Inst Green Chem & Chem Technol, Sch Chem & Chem Engn, Zhenjiang 212013, Peoples R China
[2] Changan Univ, Sch Mat Sci & Engn, Xian 710061, Shaanxi, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金; 美国国家科学基金会;
关键词
CDTE QUANTUM DOTS; SENSITIVE DETECTION; CARBON DOTS; SILICA NANOPARTICLE; SELECTIVE DETECTION; GOLD NANOCLUSTERS; ENERGY-TRANSFER; MERCURIC IONS; COPPER IONS; PROBE;
D O I
10.1039/c7nj03015k
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this paper, a highly stable ratiometric fluorescence probe based on dual-emission quantum dots (QDs) was designed for the visual detection of aspirin. The probe was composed of two differently colored CdTe QDs, in which red-emitting QDs embedded in SiO2 (r-QDs@SiO2) acted as the reference signal and green-emitting QDs (g-QDs) covalently anchored on the surface of r-QDs@SiO2 served as the response signal. The fluorescence of r-QDs@SiO2 remained constant, whereas the fluorescence of g-QDs was quenched by the addition of aspirin. As a result, continuous color changes in the dual-emission fluorescence probe were observed. Under optimum conditions, the as-prepared dual-emission fluorescence probe was used for the determination of aspirin in a concentration range of 6.0-45 mu mol L-1 with a detection limit of 0.20 mu mol L-1. Furthermore, the present method was successfully applied in the detection of aspirin in real samples with a relatively high stability for about ten days.
引用
收藏
页码:14551 / 14556
页数:6
相关论文
共 50 条
  • [1] Specific enzymatic synthesis of 2,3-diaminophenazine and copper nanoclusters used for dual-emission ratiometric and naked-eye visual fluorescence sensing of choline
    Bu, Xiangning
    Fu, Yongxin
    Jin, Hui
    Gui, Rijun
    NEW JOURNAL OF CHEMISTRY, 2018, 42 (21) : 17323 - 17330
  • [2] A ratiometric chemodosimeter for highly selective naked-eye and fluorogenic detection of cyanide
    Lin, Wei-Chi
    Hu, Jiun-Wei
    Chen, Kew-Yu
    ANALYTICA CHIMICA ACTA, 2015, 893 : 91 - 100
  • [3] Naked-eye and ratiometric fluorescence probe for fast and sensitive detection of hydrogen sulfide and its application in bioimaging
    Ma, Jianlong
    Li, Feifei
    Li, Qiang
    Li, Yijing
    Yan, Chaoxian
    Lu, Xiaofeng
    Guo, Yong
    NEW JOURNAL OF CHEMISTRY, 2018, 42 (23) : 19272 - 19278
  • [4] Visual and Fluorescent Detection of Tyrosinase Activity by Using a Dual-Emission Ratiometric Fluorescence Probe
    Yan, Xu
    Li, Hongxia
    Zheng, Weishi
    Su, Xingguang
    ANALYTICAL CHEMISTRY, 2015, 87 (17) : 8904 - 8909
  • [5] Dual-emission ratiometric nanoprobe for visual detection of Cu(II) and intracellular fluorescence imaging
    Yang, Yu Zhu
    Xiao, Na
    Cen, Yu Yan
    Chen, Jing Rong
    Liu, Shi Gang
    Shi, Yan
    Fan, Yu Zhu
    Li, Nian Bing
    Luo, Hong Qun
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2019, 223
  • [6] Carbon dots-based dual-emission ratiometric fluorescence sensor for dopamine detection
    An, Jia
    Chen, Meizhu
    Hu, Nan
    Hu, Yongqin
    Chen, Rubing
    Lyu, Ying
    Guo, Wenxi
    Li, Lijie
    Liu, Yufei
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2020, 243
  • [7] Design of dual-emission chemosensors for ratiometric detection of ATP derivatives
    Ojida, Akio
    Miyahara, Yoshifumi
    Wongkongkatep, Ararut
    Tamaru, Shun-ichi
    Sada, Kazuki
    Hamachi, Itaru
    CHEMISTRY-AN ASIAN JOURNAL, 2006, 1 (04) : 555 - 563
  • [8] Ratiometric fluorescence detection of a tag fused protein using the dual-emission artificial molecular probe
    Honda, Kei
    Nakata, Eiji
    Ojida, Akio
    Hamachi, Itaru
    CHEMICAL COMMUNICATIONS, 2006, (38) : 4024 - 4026
  • [9] Naked-Eye Detection of Glucose in Saliva with Bienzymatic Paper-Based Sensor
    Santana-Jimenez, Luis A.
    Marquez-Lucero, Alfredo
    Osuna, Velia
    Estrada-Moreno, Ivan
    Dominguez, Rocio B.
    SENSORS, 2018, 18 (04)
  • [10] Dual-emission ratiometric fluorescence probe based on copper nanoclusters for the detection of rutin and picric acid
    Lin, Qing
    Chu, Hongtao
    Chen, Jiaqi
    Gao, Lidi
    Zong, Wei
    Han, Shuang
    Li, Jinlong
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 270