The effectiveness of bulk hydrophobic treatment against corrosion of galvanized steel reinforcement in concrete specimens with w/c = 0.45 and w/c = 0.75 was compared with that of surface treatment, even in the presence of cracks 0.5 and 1 mm wide in the concrete cover. In this case surface hydrophobic treatments were applied both before and after cracking as a preventive and a restorative method against reinforced concrete deterioration, respectively. The obtained results in terms of water absorption, electrochemical measurements, chlorides penetration, and visual observations carried out on reinforced concrete specimens during the exposure to wet-dry cycles in 10% NaCl solution showed that bulk hydrophobization is the most effective treatment in improving the corrosion resistance of galvanized steel reinforcements in concrete also in the presence of cracks. Surface hydrophobization is very effective just in the first few exposure cycles to the aggressive environment and when used as a restorative method which is able to cancel the deleterious effect of cracks only 0.5 mm wide. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:609 / 614
页数:6
相关论文
共 50 条
  • [1] The effect of silane-based hydrophobic admixture on corrosion of galvanized reinforcing steel in concrete
    Tittarelli, F.
    Moriconi, G.
    CORROSION SCIENCE, 2010, 52 (09) : 2958 - 2963
  • [2] Effect of surface condition on the initial corrosion of galvanized reinforcing steel embedded in concrete
    Tan, Z. Q.
    Hansson, C. M.
    CORROSION SCIENCE, 2008, 50 (09) : 2512 - 2522
  • [3] CORROSION OF STEEL AND GALVANIZED STEEL IN CONCRETE
    CORNET, I
    BRESLER, B
    MATERIALS PROTECTION, 1966, 5 (04): : 69 - &
  • [4] Bond of ribbed galvanized reinforcing steel in concrete
    Kayali, O
    Yeomans, SR
    CEMENT & CONCRETE COMPOSITES, 2000, 22 (06): : 459 - 467
  • [5] Influence of the conversion coating on the corrosion of galvanized reinforcing steel
    Arenas, MA
    Casado, C
    Nobel-Pujol, V
    de Damborenea, J
    CEMENT & CONCRETE COMPOSITES, 2006, 28 (03): : 267 - 275
  • [6] The effect of silane-based hydrophobic admixture on corrosion of reinforcing steel in concrete
    Tittarelli, F.
    Moriconi, G.
    CEMENT AND CONCRETE RESEARCH, 2008, 38 (11) : 1354 - 1357
  • [7] RELATIONSHIPS BETWEEN CONCRETE DETERIORATION AND REINFORCING-STEEL CORROSION
    RAHARINAIVO, A
    BREVET, P
    GRIMALDI, G
    PANNIER, G
    DURABILITY OF BUILDING MATERIALS, 1986, 4 (02): : 97 - 112
  • [8] GALVANIZED STEEL PROTECTS AGAINST CORROSION
    不详
    CORROSION PREVENTION & CONTROL, 1994, 41 (05): : 105 - 106
  • [9] Corrosion of reinforcing steel in concrete sewers
    Song, Yarong
    Wightman, Elaine
    Tian, Yimei
    Jack, Kevin
    Li, Xuan
    Zhong, Huiyun
    Bond, Philip L.
    Yuan, Zhiguo
    Jiang, Guangming
    SCIENCE OF THE TOTAL ENVIRONMENT, 2019, 649 (739-748) : 739 - 748
  • [10] CORROSION AND PROTECTION OF REINFORCING STEEL IN CONCRETE
    MIYAGAWA, T
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1990, 76 (09): : 1449 - 1457