Design and Characterization of High-Sensitivity Magnetostrictive Tactile Sensor Array

被引:14
|
作者
Yang, Huiwen [1 ,2 ]
Weng, Ling [1 ,2 ]
Wang, Bowen [1 ,2 ]
Huang, Wenmei [1 ,2 ]
机构
[1] Hebei Univ Technol, State Key Lab Reliabil & Intelligence Elect Equip, Sch Elect Engn, Tianjin 300130, Peoples R China
[2] Hebei Univ Technol, Key Lab Electromagnet Field & Elect Apparat Relia, Sch Elect Engn, Tianjin 300130, Peoples R China
关键词
Inverse magnetostrictive effect; tunnel magnetoresistance; Galfenol; high sensitivity; robotic tactile perception; STIFFNESS; FORCE;
D O I
10.1109/JSEN.2022.3145822
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new high-sensitivity magnetostrictive tactile sensor array is designed based on the inverse magnetostrictive effect and tunnel magnetoresistance to enable intelligent robots to have a sensitive sense of touch and perform delicate operations. The output voltage model of the tactile sensor is developed. The optimal bias field and spacing of the sensor unit are determined using COMSOL Multiphysics. Test platforms for static and dynamic characteristics are built. The output characteristics of the tactile sensor under static and dynamic forces are tested. The sensitivity is compared with that of other types of tactile sensors. The tactile sensor units are set into a 2 x 3 sensor array and the coupling effect of the output voltage of each unit in the array is tested. The experimental results show that the experimental value of the output voltage matches the calculated value with a maximum error of 3.47%. The sensitivity of the tactile sensor is 323 mV/N at 0-4 N static force, which is higher compared to other types of tactile sensors. The sensitivity of the sensor unit changes less than 1.15% at 1-4 Hz dynamic force. The interaction of output voltage between units in the 2 x 3 tactile sensor array does not exceed 1.5% and is negligible. The 2 x 3 tactile sensor array is attached to a three-finger manipulator for grasping objects with a different hardness. The results of the study have guiding significance to the design of high-sensitivity tactile sensors for intelligent robots.
引用
收藏
页码:4004 / 4013
页数:10
相关论文
共 50 条
  • [1] Design and Output Characteristics of Bionic Magnetostrictive Tactile Sensor Array
    Liu S.
    Wang B.
    Huang W.
    Weng L.
    Gao S.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2021, 36 (12): : 2576 - 2584
  • [2] Magnetostrictive Tactile Sensor Array for Object Recognition
    Zhang, Bing
    Wang, Bowen
    Li, Yunkai
    Huang, Wenmei
    Li, Yongjian
    IEEE TRANSACTIONS ON MAGNETICS, 2019, 55 (07)
  • [3] Magnetostrictive tactile sensor array for force and stiffness detection
    Weng, Ling
    Xie, Guanran
    Zhang, Bing
    Huang, Wenmei
    Wang, Bowen
    Deng, Zhangxian
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2020, 513
  • [4] Biomimetic Tactile Sensor Array Based on Magnetostrictive Materials
    Gao, Shaoyang
    Weng, Ling
    Deng, Zhangxian
    Wang, Bowen
    Huang, Wenmei
    IEEE SENSORS JOURNAL, 2021, 21 (12) : 13116 - 13124
  • [5] Design of magnetostrictive tactile sensor for depth detection
    Weng, Ling
    Li, Zhuolin
    Luo, Xu
    Zhang, Yuanye
    Liu, Yang
    SENSOR REVIEW, 2023, 43 (04) : 249 - 258
  • [6] Design and characterization of high-sensitivity cantilevers
    Yu, XM
    Zhang, HT
    Li, XH
    Li, T
    Zhang, DC
    2005 IEEE SENSORS, VOLS 1 AND 2, 2005, : 588 - 591
  • [7] Flexible magnetostrictive tactile sensor array for pressure and stiffness detection
    Weng L.
    Gao S.
    Wang B.
    Huang W.
    Sun Y.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2020, 41 (09): : 110 - 120
  • [8] A High-Sensitivity Tactile Sensor Array Based on Fiber Bragg Grating Sensing for Tissue Palpation in Minimally Invasive Surgery
    Li, Tianliang
    Shi, Chaoyang
    Ren, Hongliang
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2018, 23 (05) : 2306 - 2315
  • [9] High-sensitivity triaxial tactile sensor with elastic microstructures pressing on piezoresistive cantilevers
    Nguyen Thanh-Vinh
    Nguyen Binh-Khiem
    Takahashi, Hidetoshi
    Matsumoto, Kiyoshi
    Shimoyama, Isao
    SENSORS AND ACTUATORS A-PHYSICAL, 2014, 215 : 167 - 175
  • [10] A high-sensitivity 3-D tactile sensor for minimally invasive surgery
    Katragadda, Rakesh B.
    Wang, Zhuo
    Xu, Yong
    2007 IEEE SENSORS, VOLS 1-3, 2007, : 808 - 810