CFD Investigation of the Optimal Ventilation System for a Single-Family Room Neonatal Intensive Care Unit

被引:0
|
作者
Osman, Hesham Safwat [1 ]
Elbaz, Ahmed M. R. [1 ]
Antar, Ahmed Hossam [1 ]
机构
[1] British Univ Egypt, Dept Mech Engn, Cairo, Egypt
来源
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Newborns are immunocompromised, and they are more susceptible to get infected than elders, hence, they should be kept in an aseptic environment that is almost free of microorganisms. A neonatal intensive care unit (NICU) is intended for caring for ill, premature and low-birth-weight infants. There are 2 main types of NICUs: the open-bay (OBA) NICU and single-family room (SFR) NICU. Researches have proved that the SFR NICUs have many advantages as compared with the OBA NICUs,hence, SFR NICUs are predominant worldwide since 1994. The ventilation system has a crucial role in the infection prevention and control (IPC) program, as it is responsible for diluting and removing various airborne contaminants from the NICU space as well as maintaining indoor thermal comfort. The locations and the types of the supply air outlets and exhaust air inlets strongly influence the performance of the ventilation system, consequently, the main objective of the paper is to find the optimal types and positions of the supply air outlets and exhaust air inlets for a ventilation system used in SFR NICUs. Two main indices were used to assess the performance of the ventilation system, which are the Air Diffusion Performance Index (ADPI) and the air change effectiveness (ACE). 13 ventilation cases were investigated and assessed based on the 2 indices. Results have proved that,for SFR NICUs, it is not recommended to use Group E supply outlets with low sidewall return grilles, or to use ceiling supply diffusers of Group A type with either ceiling return grilles or low sidewall return grilles. It is recommended to use a single high sidewall supply grille with a single low sidewall return grille, where the low sidewall return grille is located on the wall that is close to the isolette, while the high sidewall supply grille is located on the opposite wall. Moreover, results have proved that the value of ACE calculated at the breathing plane is almost equal to the ACE values calculated at the occupied and breathing zones except for ventilation systems that have Group E supply outlets, consequently, this would help to reduce the number of measurement points,especially for ACE practical measurements based on tracer gas methods.
引用
收藏
页码:300 / 308
页数:9
相关论文
共 50 条
  • [1] Single-Family Room Design in the Neonatal Intensive Care Unit-Challenges and Opportunities
    White, Robert D.
    NEWBORN AND INFANT NURSING REVIEWS, 2010, 10 (02) : 83 - 86
  • [2] The Single-Family Room Neonatal Intensive Care Unit-Critical for Improving Outcomes?
    Jobe, Alan H.
    JOURNAL OF PEDIATRICS, 2017, 185 : 10 - 12
  • [3] Single-family room design in the neonatal intensive care unit did not improve growth
    Tandberg, Bente Silnes
    Froslie, Kathrine Frey
    Markestad, Trond
    Flacking, Renee
    Grundt, Hege
    Moen, Atle
    ACTA PAEDIATRICA, 2019, 108 (06) : 1028 - 1035
  • [4] Risk Factors for Hearing Screen Failure in a Single-Family Room Neonatal Intensive Care Unit
    Suflas, Rebecca
    Cox, Rebecca
    Viscardi, Rose M.
    Leung, Jocelyn C.
    AMERICAN JOURNAL OF PERINATOLOGY, 2024,
  • [5] Unintended Consequences of the Neonatal Intensive Care Unit Environment Integrative Review of Single-Family Room Unit Design
    Jones, Carolyn West
    Moya, Fernando
    Lynch, Natalie
    ADVANCES IN NEONATAL CARE, 2023, 23 (02) : 151 - 159
  • [6] Parent psychological wellbeing in a single-family room versus an open bay neonatal intensive care unit
    Tandberg, Bente Silnes
    Flacking, Renee
    Markestad, Trond
    Grundt, Hege
    Moen, Atle
    PLOS ONE, 2019, 14 (11):
  • [7] Single-family room neonatal intensive care unit design: do patient outcomes actually change?
    Susan E. Puumala
    Renae K. Rich
    Lonnie Roy
    Regina Reynolds
    Francesqca E. Jimenez
    Jackline G. Opollo
    Jeri Brittin
    Journal of Perinatology, 2020, 40 : 867 - 874
  • [8] Single-family room neonatal intensive care unit design: do patient outcomes actually change?
    Puumala, Susan E.
    Rich, Renae K.
    Roy, Lonnie
    Reynolds, Regina
    Jimenez, Francesqca E.
    Opollo, Jackline G.
    Brittin, Jeri
    JOURNAL OF PERINATOLOGY, 2020, 40 (06) : 867 - 874
  • [9] A Comparison of Parent Satisfaction in an Open-Bay and Single-Family Room Neonatal Intensive Care Unit
    Stevens, Dennis C.
    Helseth, Carol C.
    Khan, M. Akram
    Munson, David P.
    Reid, E. J.
    HERD-HEALTH ENVIRONMENTS RESEARCH & DESIGN JOURNAL, 2011, 4 (03) : 110 - 123
  • [10] RELEVANCE OF WAVEFORM INFORMATION DISPLAYED ON NURSES' HANDHELD DEVICES IN A SINGLE-FAMILY ROOM NEONATAL INTENSIVE CARE UNIT
    Varisco, G.
    van de Mortel, H.
    Cabrera-Quiros, L.
    Atallah, L.
    Hueske-Kraus, D.
    Long, X.
    Cottaar, E. J. E.
    Kommers, D.
    Mohns, T.
    Andriessen, P.
    van Pul, C.
    PEDIATRIC RESEARCH, 2019, 86 : 52 - 53