PARTIAL IMPEDANCE SPECTROSCOPY TESTS OF A 6 KW PROTON EXCHANGE MEMBRANE WATER ELECTROLYZER STACK

被引:0
|
作者
Han, Taehee [1 ]
Salehfar, Hossein [1 ]
Dale, Nilesh V.
Mann, Mike D.
Thakare, Jivan N.
机构
[1] Univ N Dakota, Dept Elect Engn, Grand Forks, ND 58201 USA
关键词
FUEL-CELL STACK; SOLID POLYMER ELECTROLYTE; DISPERSION; DIAGNOSIS;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Impedance characteristics of a 6 kW proton exchange membrane (PEM) electrolyzer stack are presented under various operating conditions. An electrolyzer stack was operated under room temperature and partial current range (0 to 80 A). The whole stack impedance spectrums were measured by three different power supply configurations. The total sweeping frequency range (0.5 Hz to 20 kHz) is divided into low frequency (0.5 to 20 Hz), middle frequency (20 Hz to 1 kHz), and high frequency (1 to 20 kHz). Each frequency range required a different measurement setup to measure the whole stack impedance data. In this study, the partial impedance spectrums at low and high frequency ranges are successfully measured and analyzed. The measured data is verified with Kramers-Kronig relations. Measurement issues at the middle frequency region are discussed.
引用
收藏
页码:741 / 745
页数:5
相关论文
共 50 条
  • [1] Semiempirical model based on thermodynamic principles for determining 6 kW proton exchange membrane electrolyzer stack characteristics
    Dale, N. V.
    Mann, M. D.
    Salehfar, H.
    JOURNAL OF POWER SOURCES, 2008, 185 (02) : 1348 - 1353
  • [2] Progress in the proton exchange membrane for PEM water electrolyzer
    Yu, Jun (yujun@whut.edu.cn), 1600, Materials China (36):
  • [3] Investigation of the Degradation of the Membrane Electrode Assembly for a Proton Exchange Membrane Water Electrolyzer by Accelerated Stress Tests
    Kozlova, M. V.
    Pushkareva, I. V.
    Butrim, S. I.
    Solovyev, M. A.
    Simkin, D. A.
    Grigoriev, S. A.
    Pushkarev, A. S.
    NANOBIOTECHNOLOGY REPORTS, 2023, 18 (SUPPL 2) : S375 - S388
  • [4] Investigation of the Degradation of the Membrane Electrode Assembly for a Proton Exchange Membrane Water Electrolyzer by Accelerated Stress Tests
    M. V. Kozlova
    I. V. Pushkareva
    S. I. Butrim
    M. A. Solovyev
    D. A. Simkin
    S. A. Grigoriev
    A. S. Pushkarev
    Nanobiotechnology Reports, 2023, 18 : S375 - S388
  • [5] Data-Driven Temperature Deviation Estimation of a Proton Exchange Membrane Water Electrolyzer Stack from Electrochemical Impedance Using Machine Learning
    Katayama, Noboru
    Iki, Ryoma
    Chen, Xing-Xing
    Loo, Ka-Hong
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2025,
  • [6] Development and testing of a highly efficient proton exchange membrane (PEM) electrolyzer stack
    Selamet, Omer Faruk
    Becerikli, Fatih
    Mat, Mahmut D.
    Kaplan, Yuksel
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2011, 36 (17) : 11480 - 11487
  • [7] Quantitative investigation of internal polarization in a proton exchange membrane water electrolyzer stack using distribution of relaxation times
    Zuo, Jian
    Steiner, Nadia Yousfi
    Li, Zhongliang
    Hissel, Daniel
    APPLIED ENERGY, 2025, 386
  • [8] Multiphase, multidimensional modeling of proton exchange membrane water electrolyzer
    Qian, Xiao
    Kim, Kangsan
    Jung, Seunghun
    ENERGY CONVERSION AND MANAGEMENT, 2022, 268
  • [9] Investigations on high performance proton exchange membrane water electrolyzer
    Ma, Lirong
    Sui, Sheng
    Zhai, Yuchun
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2009, 34 (02) : 678 - 684
  • [10] Materials for Proton Exchange Membrane water electrolyzer bipolar plates
    Laedre, Sigrid
    Kongstein, Ole Eduard
    Oedegaard, Anders
    Karoliussen, Havard
    Seland, Frode
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (05) : 2713 - 2723