Electrochemical Detection of Hydroxylamine via Au-Pt Alloy Nanoparticle-modified Single-walled Carbon Nanotube Electrodes

被引:12
|
作者
Geng, Yanfang [1 ]
Ko, Euna [1 ]
Van-Khue Tran [1 ]
Chung, Woo Sung [1 ]
Park, Chan Ho [1 ]
Kim, Min Ki [1 ]
Jin, Ga Hyun [1 ]
Seong, Gi Hun [1 ]
机构
[1] Hanyang Univ, Dept Bionano Engn, Ansan 425791, South Korea
基金
新加坡国家研究基金会;
关键词
Au-Pt alloy nanoparticles; single-walled carbon nanotube; hydroxylamine; electrochemical sensor; electrocatalysis; ELECTROCATALYTIC OXIDATION; OXYGEN REDUCTION; HYDRAZINE; SENSOR; ROUTE;
D O I
10.2116/analsci.33.993
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present study, we developed an electrochemical sensor for highly sensitive detection of hydroxylamine using Au-Pt alloy nanoparticles. Au-Pt alloy nanoparticles were electrochemically deposited on a working electrode made of single walled carbon nanotubes. The framework composition in the Au-Pt alloy nanoparticle was easily controlled by adjusting the Au3+:Pt4+ composition ratio in the precursor solution. Morphological and chemical characterizations of the resulting Au-Pt alloy nanoparticles were performed using field emission scanning electron microscopy, X-ray diffraction, and energy dispersion X-ray spectroscopy. When the Au3+:Pt4+ ratio in the precursor solution was 1:5, the ratio of Au:Pt atom in alloy nanoparticle was about 6:4. Au60Pt40 alloy nanoparticles were found to have the optimum synthetic ratio for hydroxylamine detection. The electrocatalytic performance of Au-Pt alloy nanoparticles in the presence of hydroxylamine was also characterized using cyclic voltammetry, differential pulse voltammetry, and chronoamperometry. In the chronoamperometric detection of hydroxylamine, the sensor exhibited a detection limit of 0.80 mu M (S/N = 3) and a high sensitivity of 184 mu A mM(-1) cm(-2). Moreover, the amperometric response of the sensor in 1 mM hydroxylamine was stable for a long time (450 s). Long-term stability tests showed that the current responses to hydroxylamine were 96, 91 and 85% of the initial signal value after storage for 5, 10, and 20 days, respectively.
引用
收藏
页码:993 / 998
页数:6
相关论文
共 50 条
  • [1] Electrochemical Detection of Hydroxylamine via Au-Pt Alloy Nanoparticle-modified Single-walled Carbon Nanotube Electrodes
    Yanfang Geng
    Euna Ko
    Van-Khue Tran
    Woo Sung Chung
    Chan Ho Park
    Min Ki Kim
    Ga Hyun Jin
    Gi Hun Seong
    Analytical Sciences, 2017, 33 : 993 - 998
  • [2] Electrochemical characterization of single-walled carbon nanotube electrodes
    Barisci, JN
    Wallace, GG
    Baughman, RH
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2000, 147 (12) : 4580 - 4583
  • [3] Gold nanoparticle-modified single-walled carbon nanotube terahertz metasurface for ultrasensitive sensing of trace proteins
    Zhang, Xiang
    Wang, Yue
    Ru, Yumen
    Zhang, Xiaoju
    Luo, Fan
    Chen, Xiangdong
    Zhao, Xiaoguang
    Wang, Chang
    TALANTA, 2025, 286
  • [4] On the Melting and Freezing of Au-Pt Nanoparticles Confined in Single-Walled Carbon Nanotubes
    Shi, Rongwei
    Shao, Jingling
    Zhu, Xiaolei
    Lu, Xiaohua
    JOURNAL OF PHYSICAL CHEMISTRY C, 2011, 115 (07): : 2961 - 2968
  • [5] Electrochemical sensing of hydroxylamine by gold nanoparticles on single-walled carbon nanotube films
    Bui, Minh-Phuong Ngoc
    Pham, Xuan-Hung
    Han, Kwi Nam
    Li, Cheng Ai
    Lee, Eun Kyu
    Chang, Ho Jung
    Seong, Gi Hun
    ELECTROCHEMISTRY COMMUNICATIONS, 2010, 12 (02) : 250 - 253
  • [6] The Preparation of Ag Nanoparticle-Modified Single-Walled Carbon Nanotubes and Their Antibacterial Activity
    Kosaka, Tomomi
    Ohgami, Akie
    Nakamura, Takako
    Ohana, Tsuguyori
    Ishihara, Masatou
    BIOCONTROL SCIENCE, 2009, 14 (03) : 133 - 138
  • [7] Picomolar detection of protease using peptide/single walled carbon nanotube/gold nanoparticle-modified electrode
    Mahmoud, Khaled A.
    Hrapovic, Sabahudin
    Luong, John H. T.
    ACS NANO, 2008, 2 (05) : 1051 - 1057
  • [8] Electrochemical behavior and determination of uric acid at single-walled carbon nanotube modified gold electrodes
    Wei, SG
    Zhao, FQ
    Zeng, BZ
    MICROCHIMICA ACTA, 2005, 150 (3-4) : 219 - 224
  • [9] Electrochemical Behavior and Determination of Uric Acid at Single-Walled Carbon Nanotube Modified Gold Electrodes
    Shuhong Wei
    Faqiong Zhao
    Baizhao Zeng
    Microchimica Acta, 2005, 150 : 219 - 224
  • [10] Electrochemical sensing of bisphenol A on single-walled carbon nanotube paper electrodes
    Bui, Catalina
    La Flower, Gavin
    Paudyal, Janak
    ELECTROANALYSIS, 2023, 35 (08)