Repeatability of 2 methods for assessment of insulin sensitivity and glucose dynamics in horses

被引:0
|
作者
Pratt, SE
Geor, RJ [1 ]
McCutcheon, LJ
机构
[1] Univ Guelph, Ontario Vet Coll, Dept Biomed Sci, Guelph, ON N1G 2W1, Canada
[2] Univ Guelph, Dept Anim & Poultry Sci, Guelph, ON N1G 2W1, Canada
[3] Univ Guelph, Dept Pathobiol, Guelph, ON N1G 2W1, Canada
关键词
euglycemic-hyperinsulinemic clamp; glucose tolerance test; minimal model analysis;
D O I
10.1892/0891-6640(2005)19[883:ROMFAO]2.0.CO;2
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Both the euglycemic-hyperinsulinemic clamp (EHC) and minimal model analysis of the frequently sampled intravenous glucose tolerance test (FSIGT) have been applied for measurement of insulin sensitivity in horses. However, no published data are available on the reproducibility of these methods. Therefore, the objective of this study was to evaluate the variation and repeatability of measures of glucose dynamics and insulin sensitivity in horses derived from minimal model analysis of the FSIGT and from the EHC method. Six healthy horses underwent both the FSIGT and EHC on 2 occasions over a 4-week period, with a minimum of 5 days between tests. Coefficient of variation (CV) and intraclass correlation coefficient (ICC) were calculated for measures of glucose metabolism and insulin sensitivity derived from each test. In the EHC, insulin sensitivity, expressed as the amount of metabolized glucose (M) per unit of serum insulin (1) (M/I ratio), averaged 0.19 +/- 0.06 X 10(-4) mmol/kg/min(.)(pmol/L)(-1) with an average interday CV of 14.1 +/- 5.7% (range, 7-20%) and ICC of 0.74. Minimal model analysis of the FSIGT demonstrated mean insulin sensitivity (Si) of 0.49 +/- 0. 17 X 10(-1)/min X (pmol/L)(-1) with an average interday CV of 23.7 +/- 11.2% (range, 9-35%) and ICC of 0.33. Mean CV and ICC for minimal model glucose effectiveness (Sg) and acute insulin response (AIRg) were, respectively, 26.4 +/- 11.2% (range 13-40%) and 0.10 and 11.7 +/- 6.5% (range 7-21%) and 0.98. Insulin sensitivity measured by the EHC has lower interday variation when compared with the minimal model estimate derived from the FSIGT.
引用
收藏
页码:883 / 888
页数:6
相关论文
共 50 条
  • [1] Repeatability of the hyperglycaemic clamp for assessment of β-cell response and insulin sensitivity in horses
    Lindase, S.
    Johansson, H.
    Mansby, M.
    Brojer, J.
    EQUINE VETERINARY JOURNAL, 2020, 52 (01) : 126 - 130
  • [2] REPEATABILITY OF THE COMBINED GLUCOSE AND INSULIN TEST IN HORSES.
    Brojer, J.
    Alvarsson, K.
    Hedenskog, J.
    Nostell, K.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2012, 26 (03) : 736 - 736
  • [3] Effects of dexamethasone on glucose dynamics and insulin sensitivity in standardbred horses.
    Tiley, H. A.
    Geor, R. J.
    McCutcheon, L. J.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2006, 20 (03) : 799 - 799
  • [4] Assessment of Insulin and Glucose Dynamics by Using an Oral Sugar Test in Horses
    Schuver, Amy
    Frank, Nicholas
    Chameroy, Kelly A.
    Elliott, Sarah B.
    JOURNAL OF EQUINE VETERINARY SCIENCE, 2014, 34 (04) : 465 - 470
  • [6] Influence of iron supplementation on insulin and glucose dynamics in horses
    Gluck, Cassandra R.
    Pratt-Phillips, Shannon E.
    JOURNAL OF ANIMAL SCIENCE, 2024, 102 : 658 - 659
  • [7] Influence of iron supplementation on insulin and glucose dynamics in horses
    Gluck, Cassandra R.
    Pratt-Phillips, Shannon E.
    JOURNAL OF ANIMAL SCIENCE, 2024, 102 : 658 - 658
  • [8] Effects of Bromocriptine on Glucose and Insulin Dynamics in Normal and Insulin Dysregulated Horses
    Loos, Caroline M. M.
    Urschel, Kristine L.
    Vanzant, Eric S.
    Oberhaus, Erin L.
    Bohannan, Adam D.
    Klotz, James L.
    McLeod, Kyle R.
    FRONTIERS IN VETERINARY SCIENCE, 2022, 9
  • [9] Repeatability of the Combined Glucose-Insulin Tolerance Test and the Effect of a Stressor before Testing in Horses of 2 Breeds
    Brojer, J.
    Lindase, S.
    Hedenskog, J.
    Alvarsson, K.
    Nostell, K.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2013, 27 (06) : 1543 - 1550
  • [10] Factors affecting clinical assessment of insulin sensitivity in horses
    Firshman, A. M.
    Valberg, S. J.
    EQUINE VETERINARY JOURNAL, 2007, 39 (06) : 567 - 575