An electrochemical aptasensor based on TiO2/MWCNT and a novel synthesized Schiff base nanocomposite for the ultrasensitive detection of thrombin

被引:71
|
作者
Heydari-Bafrooei, Esmaeil [1 ]
Amini, Maryam [1 ]
Ardakani, Mehdi Hatefi [1 ]
机构
[1] Valie E Asr Univ Rafsanjan, Fac Sci, Dept Chem, Rafsanjan 7718897111, Iran
来源
关键词
Aptamer; Thrombin; Electrochemical impedance spectroscopy; Label free detection; Multiwalled carbon nanotubes; CARBON NANOTUBES; DNA; BIOSENSOR; APTAMER; TIO2; PROTEINS; SURFACES;
D O I
10.1016/j.bios.2016.06.012
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A sensitive aptasensor based on a robust nanocomposite of titanium dioxide nanoparticles, multiwalled carbon nanotubes (MWCNT), chitosan and a novel synthesized Schiff base (SB) (TiO2/MWCNT/CHIT/SB) on the surface of a glassy carbon electrode (GCE) was developed for thrombin detection. The resultant nanocomposite can provide a large surface area, excellent electrocatalytic activity, and high stability, which would improve immobilization sites for biological molecules, allow remarkable amplification of the electrochemical signal and contribute to improved sensitivity. Thrombin aptamers were simply immobilized onto the TiO2-MWCNT/CHIT-SB nanocomposite matrix through simple pi - pi stacldng and electrostatic interactions between CHIT/SB and aptamer strands. The electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were used to analyze the surface characterization of unmodified GCE and TiO2-MWCNT/CHIT-SB modified GCE, and also the interaction between aptamer and thrombin. In the presence of thrombin, the aptamer on the adsorbent layer captures the target on the electrode interface, which makes a barrier for electrons and inhibits electron transfer, thereby resulting in decreased DPV and increased impedance signals of the TiO2-MWCNT/CHIT-SB modified GCE. Furthermore, the proposed aptasensor has a very low LOD of 1.0 fmol L-1 thrombin within the detection range of 0.00005-10 nmol L-1. The aptasensor also presents high specificity and reproducibility for thrombin, which is unaffected by the coexistence of other proteins. Clinical application was performed with analysis of the thrombin levels in blood and CSF samples obtained from patients with MS, Parkinson, Epilepsy and Polyneuropathy using both the aptasensor and commercial ELISA kit. The results revealed the proposed system to be a promising candidate for clinical analysis of thrombin. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:828 / 836
页数:9
相关论文
共 50 条
  • [1] Electrochemical aptasensor based on a novel flower-like TiO2 nanocomposite for the detection of tetracycline
    Tang, Yunfei
    Liu, Peipei
    Xu, Jun
    Li, Lele
    Yang, Liwei
    Liu, Xiaoqiang
    Liu, Shanhu
    Zhou, Yanmei
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 258 : 906 - 912
  • [2] Au/TiO2 nanorod arrays-based electrochemical aptasensor for ultrasensitive detection of adenosine
    Wang, Xuan
    Qin, Yuanlong
    Zhang, Xinyu
    Leng, Yumin
    Chen, Zhengbo
    MICROCHEMICAL JOURNAL, 2023, 190
  • [3] A new electrochemical aptasensor based on MWCNT-SiO2@Au core-shell nanocomposite for ultrasensitive detection of bisphenol A
    Razavipanah, Iman
    Rounaghi, Gholam Hossein
    Deiminiat, Behjat
    Damirchi, Saeed
    Abnous, Khalil
    Izadyar, Mohammad
    Khavani, Mohammad
    MICROCHEMICAL JOURNAL, 2019, 146 : 1054 - 1063
  • [4] Ultrasensitive label-free homogeneous electrochemical aptasensor based on sandwich structure for thrombin detection
    Zhang, Yaxing
    Xia, Jianfei
    Zhang, Feifei
    Wang, Zonghua
    Liu, Qingyun
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 267 : 412 - 418
  • [5] Label-free electrochemical aptasensor for ultrasensitive thrombin detection using graphene nanoplatelets and carbon nano onion-based nanocomposite
    Ansari, Mohd Afaque
    Liew, Wei Juen
    Kurup, Chitra Padmakumari
    Ahmed, Minhaz Uddin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2023, 937
  • [6] An electrochemical aptasensor based on a TiO2/three-dimensional reduced graphene oxide/PPy nanocomposite for the sensitive detection of lysozyme
    Wang, Minghua
    Zhai, Shuyong
    Ye, Zihan
    He, Linghao
    Peng, Donglai
    Feng, Xiaozhong
    Yang, Yanqin
    Fang, Shaoming
    Zhang, Hongzhong
    Zhang, Zhihong
    DALTON TRANSACTIONS, 2015, 44 (14) : 6473 - 6479
  • [7] Electrochemical aptasensor based on gold modified graphene nanocomposite with different morphologies for ultrasensitive detection of Pb2+
    Wang, Yaoguang
    Zhao, Guanhui
    Zhang, Qian
    Wang, Huan
    Zhang, Yong
    Can, Wei
    Zhang, Nuo
    Du, Bin
    Wei, Qin
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 288 : 325 - 331
  • [8] A competitive photoelectrochemical aptasensor for thrombin detection based on the use of TiO2 electrode and glucose oxidase label
    Cao, Jun-Tao
    Zhang, Jing-Jing
    Gong, Yun
    Ruan, Xue-Jun
    Liu, Yan-Ming
    Chen, Yong-Hong
    Ren, Shu-Wei
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 759 : 46 - 50
  • [9] Electrochemiluminescence aptasensor of TiO2/CdS:Mn hybrids for ultrasensitive detection of cytochrome c
    Bin, Na
    Li, Weili
    Yin, Xuehua
    Huang, Xiaohua
    Cai, Qingyun
    TALANTA, 2016, 160 : 570 - 576
  • [10] A hemin/rGO/MWCNT nanocomposite-based dual signal electrochemical aptasensor for sensitive detection of NSE
    Wei, Huyue
    Yang, Mingzhu
    Huang, Chengshuai
    Yue, Xiaojie
    Cai, Jiabin
    Wang, Xinyi
    Fan, Kai
    Dong, Linxi
    Wang, Gaofeng
    Li, Dujuan
    ANALYTICAL METHODS, 2024, 16 (39) : 6726 - 6735