Mitral annulus flattens in ischemic mitral regurgitation: Geometric differences between inferior and anterior myocardial infarction - A real-time 3-dimensional echocardiographic study

被引:121
|
作者
Watanabe, N
Ogasawara, Y
Yamaura, Y
Wada, N
Kawamoto, T
Toyota, E
Akasaka, T
Yoshida, K
机构
[1] Kawasaki Med Sch, Dept Cardiol, Kurashiki, Okayama 7010192, Japan
[2] Kawasaki Med Sch, Dept Med Engn & Syst Cardiol, Kurashiki, Okayama 7010192, Japan
关键词
mitral valve; regurgitation; surgery; echocardiography;
D O I
10.1161/CIRCULATIONAHA.104.524595
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-New surgical strategies to restore the saddle shape of the mitral annulus are expected to increase annuloplasty effectiveness. Preoperative and postoperative configuration of the curved annulus, however, is difficult to quantify with 2-dimensional echocardiography. We sought to investigate the geometric deformity in the mitral annulus in ischemic mitral regurgitation (MR), comparing inferior and anterior myocardial infarction (MI) with the use of a custom quantitation software system with transthoracic 3-dimensional echocardiography. Methods and Results-We performed real-time 3-dimensional echocardiography in 23 patients with ischemic MR attributable to inferior MI or anterior MI and in 10 controls. Three-dimensional data were cropped into 18 radial planes, and we manually marked the annulus in mid systole. Three-dimensional annular images were reconstructed, and annular circumferences, areas, and heights were quantified. Annulus was significantly more dilated and flattened in ischemic MR than in controls and was further deformed in anterior MI as compared with inferior MI (control: circumference 9.9 +/- 0.7 cm, area 9.6 +/- 0.5 cm(2), height 5.0 +/- 0.7 mm; inferior MI: circumference 11.5 +/- 1.2 cm [P<0.01 compared with control], area 11.4 +/- 2.0 cm(2) [P<0.05 compared with control], height 3.5 +/- 1.6 mm [P<0.05 compared with control]; anterior MI: circumference 14.2 +/- 2.4 cm [P<0.0001 compared with control, P<0.05 compared with inferior MI], area 13.7 +/- 2.8 cm(2)]p<0.01 compared with control, P<0.05 compared with inferior MI], height 1.7 +/- 1.5 mm [P<0.0001 compared with control, P<0.05 compared with inferior Ml]). Conclusions-Mitral annulus flattens in ischemic MR. Deformity of the mitral annulus was greater in anterior MI group than in the inferior MI group.
引用
收藏
页码:I458 / I462
页数:5
相关论文
共 50 条
  • [1] Mitral annulus flattens in patients with ischemic mitral regurgitation: Transthoracic real-time three-dimensional echocardiographic study
    Watanabe, N
    Akasaka, T
    Yamaura, Y
    Ogasawara, Y
    Wada, N
    Neishi, Y
    Koyama, Y
    Yoshida, K
    CIRCULATION, 2004, 110 (17) : 588 - 588
  • [2] Geometric change of mitral valve leaflets and annulus after reconstructive surgery for ischemic mitral regurgitation: Real-time 3-dimensional echocardiographic study
    Yamaura, Y
    Watanabe, N
    Ogasawara, Y
    Wada, N
    Kawamoto, T
    Toyota, E
    Akasaka, T
    Tanemoto, K
    Yoshida, K
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 130 (05): : 1459 - 1461
  • [3] Geometric deformity of the mitral annulus in patients with ischemic mitral regurgitation: A real-time three-dimensional echocardiographic study
    Watanabe, N
    Ogasawara, Y
    Yamaura, Y
    Kawamoto, T
    Akasaka, T
    Yoshida, K
    JOURNAL OF HEART VALVE DISEASE, 2005, 14 (04): : 447 - 452
  • [4] Comparing the mitral leaflet geometric differences between ischemic mitral regurgitation associated with anterior and inferior myocardial infarction
    Feng, W.
    Lee, A. P. W.
    Fang, F.
    Shang, Q.
    Wang, J.
    Liu, M.
    Yu, C. M.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 163 : S15 - S15
  • [5] Geometric deformity of the saddle-shaped mitral annulus in patients with ischemic mitral regurgitation: Real-time three-dimensional echocardiographic study
    Watanabe, N
    Yamaura, Y
    Taniguchi, M
    Kawamoto, T
    Ogasawara, Y
    Akasaka, T
    Yoshida, K
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 345A - 345A
  • [6] Geometric differences of the mitral valve tenting between anterior and inferior myocardial infarction with significant ischemic mitral regurgitation: Quantitation by novel software system with transthoracic real-time three-dimensional echocardiography
    Watanabe, Nozomi
    Ogasawara, Yasuo
    Yamaura, Yasuko
    Yamamoto, Katsunori
    Wada, Nozomi
    Kawamoto, Takahiro
    Toyota, Eiji
    Akasaka, Takashi
    Yoshida, Kiyoshi
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2006, 19 (01) : 71 - 75
  • [7] GEOMETRIC DIFFERENCES OF MITRAL APPARATUS BETWEEN INFERIOR AND ANTERIOR MYOCARDIAL INFARCTION WITH SIGNIFICANT ISCHEMIC MITRAL REGURGITATION: THREE-DIMENSIONAL ANALYSIS WITH MULTISLICE COMPUTED TOMOGRAPHY
    An, Yoshimori
    Kaji, Shuichiro
    Kim, Kitae
    Yamamuro, Atsushi
    Kinoshita, Makoto
    Ehara, Natsuhiko
    Kobori, Atsushi
    Kobori, Atsushi
    Kitai, Takeshi
    Tani, Tomoko
    Kita, Toru
    Furukawa, Yutaka
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [8] Quantitation of Mitral Annulus in Ischemic Mitral Regurgitation by 3-Dimensional Echocardiography
    Jiang, Yuwen
    Huang Guoqian
    Luo Xinping
    CIRCULATION, 2010, 122 (02) : E109 - E109
  • [9] Geometric Changes of Mitral Annulus Assessed by Real-Time 3-Dimensional Transesophageal Echocardiography
    Matsumura, Yoshiki
    Tonyo, Manatomo
    Greenberg, Neil L.
    Yamano, Tetsuhiro
    Takasaki, Kunitsugu
    Saraiva, Roberto M.
    Shiota, Takahiro
    CIRCULATION, 2008, 118 (18) : S1004 - S1004
  • [10] Geometric differences of mitral valvular apparatus between ischemic and dilated cardiomyopathy with significant mitral regurgitation: Real-time three-dimensional echocardiography study
    Kwan, J
    Shiota, T
    Gillinov, AM
    Agler, DA
    Qin, JX
    Kim, YJ
    Thomas, JD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 395A - 395A