Investigation of millimeter-wave band magnetron dispersion characteristics

被引:0
|
作者
Volovenko, M. V. [1 ]
Nikitenko, O. M. [1 ]
机构
[1] Natl Univ Radioelect, UA-61166 Kharkov, Ukraine
关键词
D O I
10.1109/CRMICO.2007.4368684
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Considered in this paper is the influence of electrode temperature on dispersion characteristics of millimeter-wave band magnetron. Cavity resonators without straps were used in millimeter-wave band magnetrons. In this case such systems have resonance equation as is shown below (1) Y-r + Y-n = 0, (1) where Y-r - cavity impedance, Y-n - interaction space impedance. The impedance of both interaction space and cavity has been defined in [1]. Dispersion characteristics of millimeter-wave band magnetron have been investigated. Calculation results are shown in Fig 1, 2. The electrodes investigation devices have changed geometrical dimensions by (2) for anode, high and width slot cavity and (3) for secondary cathode. R-z = R-z(1 + Delta t) (2) R-K = R-K .(1 + Delta t)/pi (3) where Delta - temperature expansion factor. This factor is different to anode and cathode. They have been determined separately. Dispersion characteristics of millimeter-wave band magnetron are presented in Fig 3, 4 for the case when temperature of both electrodes' is equal similar to 27 degrees C (curve 1), for the case when cathode and anode temperature is increased up to similar to 100 degrees C (curve 2) and for the case when anode temperature is increased up to similar to 100 degrees C, and cathode temperature is increased up to similar to 600 degrees C (curve 3). Using this method calculated accuracy has been achieved no more 5% compared with experimental results. Separation of magnetron oscillation were changed from 5 to 14% for different millimeter-wave band devices when the secondary cathode temperature has been changed from 27 degrees C to 250 degrees C.
引用
收藏
页码:207 / 208
页数:2
相关论文
共 50 条
  • [1] A study on 94 GHz band millimeter-wave RCS characteristics
    Yamaguchi, H
    Kajiwara, A
    Nishiyama, F
    Tanaka, T
    PROCEEDINGS OF THE 1996 IEEE NATIONAL RADAR CONFERENCE, 1996, : 333 - 338
  • [2] Characteristics of millimeter-wave antennas
    Krutko, AP
    Obolonskii, VA
    Shevchuk, BM
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII RADIOELEKTRONIKA, 2004, 47 (3-4): : 77 - 80
  • [3] Millimeter-wave band noise radar
    Lukin, K.A.
    Telecommunications and Radio Engineering (English translation of Elektrosvyaz and Radiotekhnika), 2009, 68 (14): : 1229 - 1255
  • [4] Experimental Investigation of Millimeter-Wave MIMO Channel Characteristics in Tunnel
    Liu, Xi
    Yin, Xiaoyu
    Zheng, Guoxin
    IEEE ACCESS, 2019, 7 : 108395 - 108399
  • [5] CHARACTERISTICS OF SUPERCONDUCTING CO-AXIAL LINE IN THE MILLIMETER-WAVE BAND
    GALPEROVICH, DY
    LAPTEV, AA
    KHRENKOV, NN
    TELECOMMUNICATIONS AND RADIO ENGINEERING, 1982, 36-7 (06) : 50 - 55
  • [6] Radar characteristics of water-Surface targets in millimeter-wave band
    Razskazovsky, V.B.
    Lutsenko, V.I.
    Pedenko, Yu.A.
    Telecommunications and Radio Engineering (English translation of Elektrosvyaz and Radiotekhnika), 2009, 68 (13): : 1151 - 1160
  • [7] Optimizing the spatial-harmonic millimeter-wave magnetron
    Schuenemann, K
    Serebryannikov, AE
    Sosnytskiy, SV
    Vavriv, DM
    PHYSICS OF PLASMAS, 2003, 10 (06) : 2559 - 2565
  • [8] DISPERSION OF PLANAR WAVEGUIDES FOR MILLIMETER-WAVE APPLICATION
    HOFMANN, H
    AEU-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS, 1977, 31 (01): : 40 - 44
  • [9] DISPERSION CHARACTERISTICS OF BROADSIDE COUPLED DIELECTRIC IMAGE GUIDE AT MILLIMETER-WAVE FREQUENCIES
    RASTOGI, AK
    MISHRA, S
    TIWARI, AK
    INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 1995, 16 (03): : 601 - 614
  • [10] Investigation of millimeter-wave waveguide circulator
    Shenzhen Univ, Shenzhen, China
    Tien Tzu Hsueh Pao, 6 (102-104):