Polyaniline-modified electrode as an amperometric ascorbate sensor

被引:48
|
作者
Jureviciute, I
Brazdziuviene, K
Bernotaite, L
Salkus, B
Malinauskas, A
机构
[1] Inst Chem, LT-01108 Vilnius, Lithuania
[2] Vilnius Pedagog Univ, Fac Nat Sci, Dept Chem, LT-08106 Vilnius, Lithuania
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2005年 / 107卷 / 02期
关键词
ascorbate sensor; electrocatalysis; polyaniline;
D O I
10.1016/j.snb.2004.11.075
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrochemical oxidation of ascorbate at polyaniline-modified electrode has been studied. The autocatalytic reaction mechanism has been proposed for anodic oxidation of ascorbate in nearly pH-neutral buffered solutions: protons liberated during ascorbate oxidation cause a local pH drop within a thin polyaniline layer, turning it into a proton-doped conducting form that shows electrocatalytic activity towards oxidation of ascorbate. The proposed mechanism explains the ability of polyaniline to electrocatalyze the anodic oxidation of ascorbate even in pH-neutral solutions, where polyaniline presents in its undoped and non-conducting form. It has been shown that polyaniline-modi tied electrodes can be used for ascorbate assay within a pH range of 5.5-7.2, operating potential window of 0.1-40 V versus Ag/AgCl, showing a linear range of response up to 0.6 mM, and a lower detection limit of 0.05 mM. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:716 / 721
页数:6
相关论文
共 50 条
  • [1] Amperometric sensing of ammonia in aqueous solutions using a polyaniline-modified electrode in flow injection systems
    Trojanowicz, M
    Krawczyk, TKV
    Zmorzynska, M
    Campanella, L
    ELECTROANALYSIS, 1997, 9 (14) : 1062 - 1066
  • [2] Polyaniline-modified cholinesterase sensor for pesticide determination
    Ivanov, AN
    Lukachova, L
    Evtugyn, GA
    Karyakina, EE
    Kiseleva, SG
    Budnikov, HC
    Orlov, AV
    Karpacheva, GP
    Karyakin, AA
    BIOELECTROCHEMISTRY, 2002, 55 (1-2) : 75 - 77
  • [3] Electrode reactions of several dissolved hydroquinones on a polyaniline-modified electrode and what occurs in the polyaniline
    Yano, Jun
    SURFACE & COATINGS TECHNOLOGY, 2013, 231 : 234 - 238
  • [4] Droplet-based glucosamine sensor using gold nanoparticles and polyaniline-modified electrode
    Suea-Ngam, Akkapol
    Rattanarat, Poomrat
    Wongravee, Kanet
    Chailapakul, Orawon
    Srisa-Art, Monpichar
    TALANTA, 2016, 158 : 134 - 141
  • [5] Polyaniline-Modified Quartz Crystal Microbalance Gas Sensor
    吴霞琴
    高尾雄二
    江头诚
    电化学, 1997, (03) : 102 - 105
  • [6] Molecularly imprinted polyaniline-modified electrode for quantitative detection of acetaminophen
    Ahmadi, Alireza
    Farid, Mohammad Masoudi
    Khalkhali, Sourena Masoumzadeh
    Piri, Farideh
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2025, 72 (02) : 229 - 236
  • [7] Reaction of Dissolved p-Dimethoxybenzene on a Polyaniline-Modified Electrode
    Yano, Jun
    ELECTROCHEMISTRY, 2012, 80 (09) : 629 - 631
  • [8] Development of an amperometric sulfite biosensor based on a gold nanoparticles/chitosan/multiwalled carbon nanotubes/polyaniline-modified gold electrode
    Rawal, Rachna
    Chawla, Sheetal
    Dahiya, Tulika
    Pundir, Chandra Shekhar
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (08) : 2599 - 2608
  • [9] Development of an amperometric sulfite biosensor based on a gold nanoparticles/chitosan/multiwalled carbon nanotubes/polyaniline-modified gold electrode
    Rachna Rawal
    Sheetal Chawla
    Tulika Dahiya
    Chandra Shekhar Pundir
    Analytical and Bioanalytical Chemistry, 2011, 401 : 2599 - 2608
  • [10] In situ Raman spectroelectrochemical study of electrocatalytic oxidation of ascorbate at polyaniline-and sulfonated polyaniline-modified electrodes
    Mazeikiene, R.
    Niaura, G.
    Malinauskas, A.
    ELECTROCHIMICA ACTA, 2006, 51 (26) : 5761 - 5766