Ignition of a hydrogen-air mixture by low voltage electrical contact arcs

被引:9
|
作者
Shekhar, Rajiv [1 ,2 ]
Boeck, Lorenz R. [3 ]
Uber, Carsten [1 ]
Gerlach, Udo [1 ]
机构
[1] PTB, Bundesallee 100, D-38116 Braunschweig, Germany
[2] Univ Queensland, Sch ITEE, Brisbane, Qld, Australia
[3] Calif Inst Technol GALCIT, Grad Aerosp Labs, Pasadena, CA USA
关键词
Ignition; Hydrogen; Arc; Explosion protection; OpenFOAM; Interferometry;
D O I
10.1016/j.combustflame.2017.08.006
中图分类号
O414.1 [热力学];
学科分类号
摘要
This article presents an experimental and computational study of ignition caused by a low voltage electrical contact arc. The contact arc is a transient electrical discharge which occurs due to movement of electrical contacts, for example, when two energised electrodes are separated. The physical properties of this discharge are significantly different from the more conventional high voltage spark. Its potential to cause ignition is an important consideration in international explosion protection standards. As these standards are based on unreliable empirical methods, a more fundamental investigation is warranted. This study uses a specially designed apparatus and electrical circuit to create the contact arc in a hydrogen-air mixture. The transient development of the resulting flame kernel is observed using Mach-Zehnder interferometry with high spatial and temporal resolution. These experimental results are compared to simulations of a 3-D reactive flow model with detailed chemical kinetics and molecular transport. A quantitative comparison is effected by the generation of synthetic optical phase plots from the simulation output. This comparison showed reasonable correspondence between the simulated and measured flame shape. Ignition delays and thresholds were, however, under-predicted by the model. The comparison was complicated by significant statistical scattering in the experimental results. Additional investigations into the sensitivity of the model showed good robustness to grid size variations, and that inclusion of a simplified consideration of heat transfer through the electrodes produces small differences in flame shape and ignition delay. (C) 2017 The Combustion Institute. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:236 / 246
页数:11
相关论文
共 50 条
  • [1] Spark ignition of hydrogen-air mixture
    Ono, Ryo
    Odaz, Tetsuji
    ELECTROSTATICS 2007, 2009, 142
  • [2] Ignition of Hydrogen-Air Mixture Diluted by Silane
    Tropin, D. A.
    Fedorov, A. V.
    INTERNATIONAL CONFERENCE ON THE METHODS OF AEROPHYSICAL RESEARCH (ICMAR 2016), 2016, 1770
  • [3] Ionizing-radiation ignition of a hydrogen-air mixture
    Gerasimov, GY
    HIGH ENERGY CHEMISTRY, 2002, 36 (06) : 370 - 373
  • [4] Auto-ignition of hydrogen-air mixture at elevated pressures
    Derevyago, A. N.
    Penyazkov, O. G.
    Ragotner, K. A.
    Sevruk, K. L.
    SHOCK WAVES, VOL 1, PROCEEDINGS, 2009, : 733 - 738
  • [5] Ignition and combustion of a hydrogen-air mixture in a rapid-compression combustor
    A. A. Buzukov
    Combustion, Explosion and Shock Waves, 1999, 35 : 601 - 611
  • [6] Ignition and combustion of a hydrogen-air mixture in a rapid-compression combustor
    Buzukov, AA
    COMBUSTION EXPLOSION AND SHOCK WAVES, 1999, 35 (06) : 601 - 611
  • [7] External and internal ignition of a hydrogen-air gas mixture induced by a recombiner
    Bezgodov, E. V.
    Pasyukov, S. D.
    Nikiforov, M. V.
    Tarakanov, A. A.
    Popov, I. A.
    Moshkin, Dl
    Davletchin, U. F.
    Simonenko, V. A.
    Kirillov, I. A.
    Kalyakin, S. G.
    Sedov, M. K.
    ATOMIC ENERGY, 2023, 135 (1-2) : 97 - 106
  • [8] Shock-wave ignition of a hydrogen-air mixture in a conical chamber
    Gostintsev, YA
    Gusev, PA
    Bokhon, YA
    Mineev, VN
    Naboko, IM
    Petukhov, VA
    Fortov, VE
    CHEMICAL PHYSICS REPORTS, 1997, 16 (12): : 2171 - 2187
  • [9] Minimum ignition energy of hydrogen-air mixture: Effects of humidity and spark duration
    Ono, Ryo
    Nifuku, Masaharu
    Fujiwara, Shuzo
    Horiguchi, Sadashige
    Oda, Tetsuji
    JOURNAL OF ELECTROSTATICS, 2007, 65 (02) : 87 - 93
  • [10] Ignition of lean hydrogen-air mixtures
    Swain, MR
    Filoso, PA
    Swain, MN
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2005, 30 (13-14) : 1447 - 1455