Evaluation of the uniformity of sound-masking systems in an open-plan office

被引:1
|
作者
Zarei, Farideh [1 ]
Lee, Joonhee [1 ]
Mackenzie, Roderick [2 ]
Le Men, Vincent [2 ]
机构
[1] Concordia Univ, Gina Cody Sch Engn & Comp Sci, Dept Bldg Civil & Environm Engn, 1455 De Maisonneuve Blvd W, Montreal, PQ H3G 1M8, Canada
[2] Soft dB, 250 Ave Dunbar,Suite 203, Montreal, PQ H3P 2H5, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Open-plan office; Sound-masking system; Spatial uniformity; Speech intelligibility; NOISE;
D O I
10.1016/j.apacoust.2021.108464
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Many open-plan offices adopt an electronic sound masking system in order to reduce distraction from background noises, primarily intruding speech. Sound masking systems should uniformly generate a masking sound over the entire office area to homogenize the speech privacy whilst minimising occupant perception of the masking sound. This study evaluates the spatial uniformity of the masking sound field in an example open-plan office, where the masking system was set up to represent supposedly optimal installation conditions; 1-speaker zones, individually-calibration of each zone to match the specified curve precisely, and smaller zones than typically specified. Sound level measurements performed as per ASTM E1573-18 were made at each workstation, as well as every 0.6 m across the office, for a total of 117 measurements. Measurement results show that tolerance of +/- 0.5 dB for the overall A-weighted level is only achievable at 61% of measurement locations, whilst +/- 1 dB is achievable at 99% of locations. For one-third-octave band sound pressure levels between 250 Hz and 4 kHz, +/- 2 dB is achieved only 55% of the time, and tolerance of +/- 3.5 dB is required to achieve 95% compliance with the specified curve. By using calibrated computer simulations, the study also examined parameters that can influence spatial uniformity in open-plan offices. It was found that the number of sound masking loudspeakers, partition height, and the scattering and absorption coefficient of the ceiling all affect the uniformity of the masking sound. Speech intelligibility was assessed by calculating the Articulation Index (AI) to determine an acceptable tolerance for masking sound variation. Increasing the number of loudspeakers was the most effective way to improve the uniformity of the masking sound. The AI results suggest +/- 2 dB, when including octave band sound pressure levels, is a minimum required tolerance for a sound masking sound field in an open office to provide AI values within +/- 0.1 of the targeted value across the office area. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Prediction of the Effectiveness of a Sound-Masking System in an Open-Plan Office Including the Lombard Effect
    Lei, Yizhong
    Hodgson, Murray
    ACTA ACUSTICA UNITED WITH ACUSTICA, 2013, 99 (05) : 729 - 736
  • [2] SOUND-ATTENUATION IN AN OPEN-PLAN OFFICE
    LERRO, JP
    DESIGN NEWS, 1979, 35 (10) : 30 - &
  • [3] Hybrid active noise barrier with sound masking in open-plan offices
    Wang, Xun
    Koba, Yousuke
    Ishikawa, Satoshi
    Kijimoto, Shinya
    NOISE CONTROL ENGINEERING JOURNAL, 2016, 64 (03) : 403 - 415
  • [4] Evidence for the open-plan office
    Wong, Marcus
    OCCUPATIONAL MEDICINE-OXFORD, 2019, 69 (07): : 470 - 470
  • [5] DESIGNING AN OPEN-PLAN OFFICE
    LORIMER, AG
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1970, 48 (01): : 98 - &
  • [6] Effects of the location of sound masking loudspeakers on cognitive performance in open-plan offices: Local sound masking is as efficient as conventional sound masking
    Renz, Tobias
    Leistner, Philip
    Liebl, Andreas
    APPLIED ACOUSTICS, 2018, 139 : 24 - 33
  • [7] Reducing noise nuisance in open-plan office rooms by masking unwanted sounds with pyramid-shaped sound columns
    Mikulski, Witold
    MEDYCYNA PRACY-WORKERS HEALTH AND SAFETY, 2022, 73 (03): : 229 - 240
  • [8] OPEN-PLAN OFFICE, CONCEPTS AND ATTRIBUTES
    PROPST, RL
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1970, 47 (1P1): : 78 - &
  • [9] Evaluation of acoustic characteristics of Chinese open-plan office environment
    Jiao, Fenglei
    Kang, Jian
    Zhang, Mei
    Shengxue Xuebao/Acta Acustica, 2010, 35 (02): : 179 - 184
  • [10] OPEN-PLAN OFFICE LIGHTING.
    Orfield, Steven J.
    Lighting Design and Application: LD and A, 1987, 17 (07) : 7 - 19