Flow-through sensor with Fourier transform Raman detection for determination of sulfonamides

被引:15
|
作者
Rama, MJR [1 ]
López-Sánchez, M [1 ]
Ruiz-Medina, A [1 ]
Molina-Diaz, A [1 ]
Ayora-Cañada, MJ [1 ]
机构
[1] Univ Jaen, Fac Expt Sci, Dept Phys & Analyt Chem, Jaen 23071, Spain
关键词
D O I
10.1039/b510410f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-through sensor system with Fourier transform (FT) Raman spectroscopy as detection technique is described. The molecular and structural information contained in Raman spectra together with the selective retention of the species of interest on the sorbent make the proposed methodology highly selective. The flow-through sensor allowed the direct quantitative determination of sulfathiazole and sulfamethoxazole in the presence of other species that are normally encountered with these analytes. The system used Sephadex QAE A-25 resin as packing material of a flow-through cell on which sulfonamides were temporarily retained. Samples were transported by a carrier solution of NaOH 10(-2) mol l(-1) (pH = 12), and 2 ml of a [NaCl (0.10 mol l(-1))/NaOH (10(-2) mol l(-1))] solution was employed as eluent. Using a sample volume of 1 ml, the analytical signal was linear in the range 0.5-7 g l(-1) and 0.5-10 g l(-1), for sulfathiazole and sulfamethoxazole, respectively. RSDs (%) lower than 4% were obtained for both analytes. The sensor was satisfactorily applied to several commercial pharmaceutical preparations for human and animals in different physical presentations, including capsules, syrup, tablets, powders, injectables and suspensions.
引用
收藏
页码:1617 / 1623
页数:7
相关论文
共 50 条
  • [1] FLOW-THROUGH PHOTOMETRIC SENSOR FOR DETERMINATION OF SULFONAMIDES
    TENA, MT
    DECASTRO, MDL
    VALCARCEL, M
    ANALYST, 1994, 119 (07) : 1625 - 1628
  • [2] Flow-Through Fourier Transform Infrared Sensor for Total Hydrocarbons Determination in Water
    Perez-Palacios, David
    Armenta, Sergio
    Lendl, Bernhard
    APPLIED SPECTROSCOPY, 2009, 63 (09) : 1015 - 1021
  • [3] FLUOROMETRIC FLOW-THROUGH SENSOR FOR THE DETERMINATION OF PYRIDOXAL
    CHEN, DH
    DECASTRO, MDL
    VALCARCEL, M
    MICROCHEMICAL JOURNAL, 1991, 44 (02) : 215 - 221
  • [4] FLOW-THROUGH SENSOR FOR THE FLUOROMETRIC-DETERMINATION OF CYANIDE
    CHEN, DH
    DECASTRO, MDL
    VALCARCEL, M
    TALANTA, 1990, 37 (11) : 1049 - 1055
  • [5] SPECTROFLUORIMETRIC FLOW-THROUGH SENSOR FOR THE DETERMINATION OF BERYLLIUM IN ALLOYS
    DELATORRE, M
    FERNANDEZGAMEZ, F
    LAZARO, F
    DECASTRO, MDL
    VALCARCEL, M
    ANALYST, 1991, 116 (01) : 81 - 83
  • [6] Flow-through spectrofluorimetric sensor for the determination of glycerol in wine
    Canizares, P
    deCastro, MDL
    ANALYST, 1995, 120 (12) : 2837 - 2840
  • [7] A novel chemiluminescence flow-through sensor for the determination of analgin
    Yu-Ming Huang
    Chao Zhang
    Xin-Rong Zhang
    Zhu-Jun Zhang
    Fresenius' Journal of Analytical Chemistry, 1999, 365 : 381 - 383
  • [8] Flow-through sensor for determination of butylated hydroxytoluene in cosmetics
    Capitán-Vallvey, LF
    Valencia, MC
    Nicolás, EA
    ANALYTICAL LETTERS, 2002, 35 (01) : 65 - 81
  • [9] A novel chemiluminescence flow-through sensor for the determination of analgin
    Huang, YM
    Zhang, C
    Zhang, XR
    Zhang, ZJ
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (04): : 381 - 383
  • [10] DETERMINATION OF COBALT IN WATER USING A FLOW-THROUGH SENSOR SYSTEM
    TRUTNEVA, LM
    SHVOEVA, OP
    SAVVIN, SB
    JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 49 (05) : 426 - 429