Registration using three-dimensional laser surface scanning for navigation in oral and craniomaxillofacial surgery

被引:1
|
作者
Troitzsch, D
Hoffmann, J
Dammann, F
Bartz, D
Reinert, S
机构
[1] Univ Klinikum Tubingen, Klin & Poliklin Mund Kiefer & Gesichtschurg, D-72076 Tubingen, Germany
[2] Univ Klinikum Tubingen, Abt Radiol Diagnost, Radiol Univ Klin, D-72076 Tubingen, Germany
[3] Univ Tubingen, Wilhelm Schickard Inst Informat, Lehrstuhl Graph Interakt Syst, D-72074 Tubingen, Germany
来源
ZENTRALBLATT FUR CHIRURGIE | 2003年 / 128卷 / 07期
关键词
3D-laser surface scanner; registration; image-guided navigation; craniomaxillofacial surgery; IMAGE-GUIDED SURGERY; SURGICAL NAVIGATION; ACCURACY; SYSTEMS; HEAD; CT; NEURONAVIGATION; VISUALIZATION; PRECISION; IMPLANTS;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Recent innovations in laser scanning technology provide a potentially useful tool for three-dimensional surface registration for image-guided surgery. The purpose of this study is to evaluate the clinical reliability of this technique in oral and maxillofacial surgical procedures using image-guided navigation. Methods: In an experimental step, a stable anthropomorphic skull model with prelabeled markers was scanned and registered with laser surface scanning (z-touch(R), BrainLAB) and marker-based algorithms. The registration protocol was then repeated 25-times. Root mean square error (RMSE) and target difference values were compared for their suitability for this application. Twelve patients with different indications for oral and maxillofacial surgery were planned for image-guided surgery using a passive infrared surgical navigation system (VectorVision(R), BrainLAB). Preoperative computed tomography (CT) scans were carried out with newest 16-line multisclice CT-scanner (Siemens Somatom Sensation 16). The new markerless laser surface scanning technique was applied in all intraoperative patient registrations. Registration error was noted. The clinical application accuracy was determined for anatomical landmark localization deviation. Results: In the experimental protocol a mean registration error (RMSE) or target difference of 1.3 (0.14) or 2.08 (0.49) mm for laser scanning and 0.38 (0.01) or 0.99 (0.15) mm for marker registration was found. The differences for RMSE and target localization were statistically significant (p < 0.005). Furthermore, a strong correlation between RMSE and target difference was found for laser scanning (r = 0.96) and marker registration (r = 0.95). During various clinical procedures involving oral and maxillofacial surgery, the overall error of the registration procedure determined as RMSE was 1.21 (0.34) mm. Intraoperatively, the mean clinical application accuracy was found to be 1.8 (0.5) mm. Conclusion: Three-dimensional laser surface scanning technique may be a interesting and useful approach to register the patient for image-guided procedures, particularly during oral and craniomaxillofacial surgery.
引用
收藏
页码:551 / 556
页数:6
相关论文
共 50 条
  • [1] Evaluation of oral scanning in comparison to impression using three-dimensional registration
    Brogle-Kim, Yur-Chung
    Deyhle, Hans
    Mueller, Bert
    Schulz, Georg
    Bormann, Therese
    Beckmann, Felix
    Jaeger, Kurt
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VIII, 2012, 8506
  • [2] Three-dimensional Laser Surface Scanning in Rhinosurgery
    Largo, Rene D.
    Wettstein, Reto
    Fulco, Ilario
    Tremp, Mathias
    Schaefer, Dirk J.
    Gubisch, Wolfgang
    Haug, Martin D.
    FACIAL PLASTIC SURGERY, 2013, 29 (02) : 116 - 120
  • [3] Facial asymmetry: Three-dimensional analysis using laser surface scanning
    O'Grady, KF
    Antonyshyn, OM
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1999, 104 (04) : 928 - 937
  • [4] Three-dimensional analysis of the accuracy of optic and electromagnetic navigation systems using surface registration in live endoscopic sinus surgery
    Chang, Chih-Ming
    Jaw, Fu-Shan
    Lo, Wu-Chia
    Fang, Kai-Min
    Cheng, Po-Wen
    RHINOLOGY, 2016, 54 (01) : 88 - 94
  • [5] Three-Dimensional Analysis and Surgical Planning in Craniomaxillofacial Surgery
    Steinbacher, Derek M.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 73 (12) : S40 - S56
  • [6] Craniofacial applications of three-dimensional laser surface scanning
    Da Silveira, AC
    Daw, JL
    Kusnoto, B
    Evans, C
    Cohen, M
    JOURNAL OF CRANIOFACIAL SURGERY, 2003, 14 (04) : 449 - 456
  • [7] Three-dimensional position registration of a scanning laser-Doppler vibrometer
    Lindholm, BE
    PROCEEDINGS OF THE 14TH INTERNATIONAL MODAL ANALYSIS CONFERENCE, VOLS I & II, 1996, 2768 : 830 - 836
  • [8] Three-dimensional analysis of the surface registration accuracy of electromagnetic navigation systems in live endoscopic sinus surgery
    Chang, Chih-Ming
    Fang, Kai-Min
    Huang, Tsung-wei
    Wang, Chi-Te
    Cheng, Po-Wen
    RHINOLOGY, 2013, 51 (04) : 343 - 348
  • [9] Three-dimensional quantification of facial symmetry in adolescents using laser surface scanning
    Djordjevic, Jelena
    Toma, Arshed M.
    Zhurov, Alexei I.
    Richmond, Stephen
    EUROPEAN JOURNAL OF ORTHODONTICS, 2014, 36 (02) : 125 - 132
  • [10] Endoscopic Navigation Based on Three-dimensional Structure Registration
    Han, Minghui
    Dai, Yu
    Zhang, Jianxun
    2020 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS), 2020, : 2900 - 2905