The applicability of the ProSeal laryngeal mask airway for laparotomies

被引:9
|
作者
Borkowski, A [1 ]
Perl, T [1 ]
Heuer, J [1 ]
Timmermann, A [1 ]
Braun, U [1 ]
机构
[1] Univ Gottingen, Zentrum Anaesthesiol Rettungs & Intens Med, D-3400 Gottingen, Germany
关键词
ProSeal-LMA; laryngeal mask airway; endotracheal intubation; laparotomy; gastric tube; sore throat;
D O I
10.1055/s-2005-870103
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: The ProSeal laryngeal mask airway (PLMA) has some design features, which in contrast to the classic LMA allow separation of the respiration from the gastrointestinal canal, a higher leak pressure and a better position assessment. It can be debated if these instrumental improvements justify the application of the PLMA for elective abdominal surgery in cases without aspiration risk. Insertion of airway instruments and gastric tube with regard to insertion time and difficulties and frequency of side effects were to be compared for the tracheal tube and the PLMA. The pharyngolaryngeal morbidity for both methods was also of interest. It was approached with direct and indirect postoperative interview techniques. Methods: 65 patients were investigated both at the university hospital and at the hospital Neu-Bethlehem in Goettingen. The surgical intervention was a surgical or gynecological laparotomy. Anaesthesia was performed with a standardized application of propofol, alfentanil and rocuronium. Glycopyrroniumbromide was applied to minimize salivation. A total of 34 patients received the PLMA, 31 were intubated. All of them were provided with a gastric tube. Results: The insertion of the PLMA took 70 seconds (21 -234) on average, the intubation 57 seconds (35 - 145). Endotracheal intubation was accomplished in a shorter time period, but there was no significant difference in comparison with the PLMA-group (p = 0,1924). Insertion of the PLMA was significantly more difficult than oral intubation (p = 0,0006). The base of the tongue and the dorsal pharyngeal wall, but not the vocal cords or the epiglottis were visible in those cases, where the PLMA could not be positioned at all. Here the tip of the cuff was bended. The time period for positioning of the gastric tube was 38 seconds (15 - 75) in the PLMA- and 57 seconds (22 - 219) in the tracheal tube group. With these results the gastric tube positioning was accomplished in a significantly shorter time period in the PLMA-group (p = 0,0267), but not at a significantly higher level of difficulty for endotracheal intubation (p = 0,6247). In one case there was regurgitation through the drainage tube without aspiration before gastric tube placement. At the direct interview 16 patients in the PLMA-group and 23 of the tube group mentioned postoperative throat symptoms. The most frequent symptom was hoarseness (11 PLMA- and 18 intubated patients). There was no significant difference between PLMA- and tracheal tube application with regard to the total number of patients with pharyngolaryngeal morbidity and the frequency of single symptoms. The same is true for the degree of the symptoms. There was a tendency for a longer prevalence of throat symptoms after intubation, but no significant difference. Conclusion: In this investigation the PLMA could be successfully applied for elective laparotomies in cases without the risk of aspiration. Proper patient selection and a deep level of anaesthesia are important. The advantage for patients receiving the PLMA is a smooth recovery without cough, but not so much a reduced amount of pharyngolaryngeal morbidity. From this observation it might be concluded that the invasiveness of the surgical intervention might also influence the tolerance for the airway instrument. The disadvantage in this study was the more difficult insertion of the PLMA compared with the oral intubation. Further studies with a larger number of patients must show if these first results of the "Proseal"-LMA for lararotomies are to be confirmed.
引用
收藏
页码:477 / 486
页数:10
相关论文
共 50 条
  • [1] The ProSeal laryngeal mask airway
    Dalgleish, DJ
    Dolgner, M
    ANAESTHESIA, 2001, 56 (10) : 1010 - 1010
  • [2] Airway protection with the ProSeal laryngeal mask airway
    Brimacombe, J
    Keller, C
    ANAESTHESIA AND INTENSIVE CARE, 2001, 29 (03) : 288 - 291
  • [3] Proseal Laryngeal mask airway or Classic Laryngeal mask airway in spontaneous ventilation?
    Galarioti, V.
    Michaloliakou, Ch.
    Kalanzi, N.
    Pagoulatou, A.
    Andrianopoulou, A.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 : 68 - 68
  • [4] The ProSeal™ laryngeal mask airway in children
    Lopez-Gil, M
    Brimacombe, J
    PEDIATRIC ANESTHESIA, 2005, 15 (03) : 229 - 234
  • [5] Comparing the ProSeal™ laryngeal mask airway with the laryngeal tube airway
    Cook, T
    ANESTHESIA AND ANALGESIA, 2003, 97 (04): : 1202 - 1202
  • [6] Comparison of Supreme Laryngeal Mask Airway and ProSeal Laryngeal Mask Airway during Cholecystectomy
    Hosten, Tulay
    Yildiz, Tulay Sahin
    Kus, Alparslan
    Solak, Mine
    Toker, Kamil
    BALKAN MEDICAL JOURNAL, 2012, 29 (03) : 314 - 319
  • [7] Comparison of safety and efficacy of Supreme laryngeal mask airway and ProSeal laryngeal mask airway
    Xue, Fu S.
    Xiong, Jun
    Wang, Qiang
    Yuan, Yu J.
    Liao, Xu
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (08) : 757 - 758
  • [8] Comparison of the standard laryngeal mask airway and the ProSeal laryngeal mask airway in obese patients
    Natalini, G
    Franceschetti, ME
    Pantelidi, MT
    Rosano, A
    Lanza, G
    Bernardini, A
    BRITISH JOURNAL OF ANAESTHESIA, 2003, 90 (03) : 323 - 326
  • [9] Airway leak pressure of the ProSeal®-laryngeal mask airway
    Freisburger, C.
    Goldmann, K.
    ANAESTHESIST, 2006, 55 (12): : 1255 - 1258
  • [10] Airway protection with the ProSeal™ laryngeal mask airway in a child
    Keller, C
    Brimacombe, J
    Von Goedecke, A
    Lirk, P
    PEDIATRIC ANESTHESIA, 2004, 14 (12) : 1021 - 1022