Current sensor fault detection and isolation method for PMSM drives, using average normalised currents

被引:51
|
作者
El Khil, S. Khojet [1 ,2 ]
Jlassi, I. [1 ,2 ]
Estima, J. O. [2 ]
Mrabet-Bellaaj, N. [1 ]
Marques Cardoso, A. J. [2 ]
机构
[1] Univ Tunis El Manar, Ecole Natl Ingenieurs Tunis, Lab Syst Elect, LR11 ES15, Tunis 1002, Tunisia
[2] Univ Beira Interior, CISE Electromechatron Syst Res Ctr, Ave Marques Avila & Bolama, P-6201001 Covilha, Portugal
关键词
Permanent magnets - Real time control - Synchronous motors;
D O I
10.1049/el.2016.2198
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new approach for current sensor fault detection and isolation (FDI) for permanent magnet synchronous motor (PMSM) drives is presented. Contrary to the classical approaches for sensors fault diagnosis, based on residual generation through observers or parity equations, the proposed technique uses the average normalised machine-phase currents. The main advantages of this approach are that it does not need any information about the PMSM or inverter models, and it involves low tuning efforts, that make it suitable for real-time implementation with good reliability. The good performance and the robustness of the proposed FDI approach are illustrated through experimental results.
引用
收藏
页码:1434 / 1435
页数:2
相关论文
共 50 条
  • [1] Current Sensor Fault Reconstruction for PMSM Drives
    Huang, Gang
    Luo, Yi-Ping
    Zhang, Chang-Fan
    He, Jing
    Huang, Yi-Shan
    SENSORS, 2016, 16 (02):
  • [2] Current Sensor Fault Detection and Identification for PMSM Drives Using Multichannel Global Maximum Pooling CNN
    Wu, Sijia
    Ma, Guangtong
    Yao, Chunxing
    Sun, Zhenyao
    Xu, Shuai
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (08) : 10311 - 10325
  • [3] Current Sensor Fault Localization and Identification of PMSM Drives Using Difference Operator
    Ma, Guangtong
    Zhang, Han
    Sun, Zhenyao
    Yao, Chunxing
    Ren, Guanzhou
    Xu, Shuai
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2023, 11 (01) : 1097 - 1110
  • [4] Current-sensor fault detection and isolation for induction-motor drives using a geometric approach
    Aguilera, F.
    de la Barrera, P. M.
    De Angelo, C. H.
    Espinoza Trejo, D. R.
    CONTROL ENGINEERING PRACTICE, 2016, 53 : 35 - 46
  • [5] Detection and Isolation of Open-Switch and Current Sensor Faults in PMSM Drives, Through Stator Current Analysis
    El Khil, S. Khojet
    Jlassi, I.
    Estima, J. O.
    Mrabet-Bellaaj, N.
    Marques Cardoso, A. J.
    2017 IEEE 11TH INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRICAL MACHINES, POWER ELECTRONICS AND DRIVES (SDEMPED), 2017, : 373 - 379
  • [6] Speed and Current Sensor Fault Detection and Isolation Based on Adaptive Observers for IM Drives
    Yu, Yong
    Wang, Ziyuan
    Xu, Dianguo
    Zhou, Tao
    Xu, Rong
    JOURNAL OF POWER ELECTRONICS, 2014, 14 (05) : 967 - 979
  • [7] A Sign Logic-Based Method of Current Sensor Fault Detection for PMSM Drivers
    Guo, Chuangqiang
    Wu, Chunya
    Liu, Hong
    JOURNAL OF SENSORS, 2021, 2021
  • [8] Two current sensor fault detection and isolation schemes for induction motor drives using algebraic estimation approach
    Rkhissi-Kammoun, Yosra
    Ghommam, Jawhar
    Boukhnifer, Moussa
    Mnif, Faisal
    MATHEMATICS AND COMPUTERS IN SIMULATION, 2019, 157 : 39 - 62
  • [9] Current Sensors Faults Detection, Isolation and Control Reconfiguration for PMSM Drives
    Grouz, F.
    Sbita, L.
    Boussak, M.
    2013 INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND SOFTWARE APPLICATIONS (ICEESA), 2013, : 321 - 326
  • [10] Fault Detection, Isolation and Control Reconfiguration of Three-Phase PMSM Drives
    Meinguet, Fabien
    Kestelyn, Xavier
    Semail, Eric
    Gyselinck, Johan
    2011 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2011,