A hollow waveguide infrared thermometer for polymer temperature measurement during injection moulding

被引:32
|
作者
Bendaka, A [1 ]
Cole, K [1 ]
Lamontagne, M [1 ]
Simard, Y [1 ]
机构
[1] Natl Res Council Canada, Ind Mat Res Inst, Boucherville, PQ J4B 6Y4, Canada
来源
JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS | 2003年 / 5卷 / 05期
关键词
pyrometer; sensor; remote; optical; polymer; process;
D O I
10.1088/1464-4258/5/5/306
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We describe a novel on-line infrared method for remote sensing of the surface and the bulk temperatures of a polymer film during injection moulding. The method may also be applied to other polymer forming processes such as extrusion and blow moulding. The key feature of the new method is the use of a hollow waveguide that is incorporated into the injection mould to transmit the thermal radiation from the target to the sensor. The main characteristic of the hollow waveguide is that it exhibits low transmission loss of the thermal energy in the mid- and far-infrared, and no end reflection. This allows measurement of quite low temperatures, as low as near room temperature. Conventional optical fibre thermometers can neither measure such low temperature ranges nor measure the polymer surface temperature. In this paper, we present the first on-line results of critical tests of the new device. A Husky injection moulding press was used for the experiments. Good correlation was found between the radiometric results and those obtained with a thermal sensor inserted near the polymer mould interface, and with infrared imaging after the polymer part was ejected from the injection mould.
引用
收藏
页码:464 / 470
页数:7
相关论文
共 50 条
  • [1] A new infrared pyrometer for polymer temperature measurement during extrusion moulding
    Bendada, A
    Lamontagne, M
    INFRARED PHYSICS & TECHNOLOGY, 2004, 46 (1-2) : 11 - 15
  • [2] Cavity temperature profile measurement during injection moulding
    Manero, F
    Patterson, WI
    Kamal, MR
    ANTEC'97 - PLASTICS SAVING PLANET EARTH, CONFERENCE PROCEEDINGS, VOLS 1 - 3, 1997, : 577 - 581
  • [3] Effect of the crystallization on the surface temperature of a polymer during injection moulding.
    Le Goff, Ronan
    Delaunay, Didier
    10TH ESAFORM CONFERENCE ON MATERIAL FORMING, PTS A AND B, 2007, 907 : 1239 - +
  • [4] Infrared Thermometer: an accurate tool for temperature measurement during renal surgery
    Marchini, Giovanni Scala
    Duarte, Ricardo Jordao
    Mitre, Anuar Ibrahim
    Tiseo, Bruno Camargo
    Cassao, Valter Dell'Acqua
    Miranda Torricelli, Fabio Cesar
    Arap, Marco Antonio
    Srougi, Miguel
    INTERNATIONAL BRAZ J UROL, 2013, 39 (04): : 572 - 578
  • [5] MEASUREMENT OF PRODUCT TEMPERATURE BY USE OF AN INFRARED THERMOMETER
    MAHNKE, CW
    SOUCHECK, JA
    INSALATA, NF
    APPLIED MICROBIOLOGY, 1973, 26 (04) : 646 - 647
  • [6] A Concept for Non-Invasive Temperature Measurement During Injection Moulding Processes
    Hopmann, Christian
    Spekowius, Marcel
    Wipperfuerth, Jens
    Schoengart, Maximilian
    PROCEEDINGS OF PPS-31: THE 31ST INTERNATIONAL CONFERENCE OF THE POLYMER PROCESSING SOCIETY, 2016, 1713
  • [7] DIRECT MEASUREMENT OF POLYMER TEMPERATURE DURING LASER ABLATION USING A MOLECULAR THERMOMETER
    LEE, IYS
    WEN, XN
    TOLBERT, WA
    DLOTT, DD
    DOXTADER, M
    ARNOLD, DR
    JOURNAL OF APPLIED PHYSICS, 1992, 72 (06) : 2440 - 2448
  • [8] Melt and mould temperature measurements for polymer injection moulding
    Speight, RG
    DAgostino, P
    Herrmann, JS
    ANTEC'97 - PLASTICS SAVING PLANET EARTH, CONFERENCE PROCEEDINGS, VOLS 1 - 3, 1997, : 568 - 572
  • [9] Reliability of an infrared auditory thermometer in the measurement of oral temperature
    Moya Villaescusa, M. Jose
    Perez, A. Sanchez
    Bermejo Fenoll, Ambrosio
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2008, 13 (06): : E385 - E389
  • [10] MEASUREMENT OF AVERAGE FACE TEMPERATURE USING INFRARED THERMOMETER
    NISHI, Y
    SUZUKI, K
    OOHORI, T
    INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 1987, 31 (04) : 354 - 355