A Method to Determine the Distance to the Critical Oscillatory Stability Limit in Terms of Active Power Injections

被引:0
|
作者
Muller, Daniel [1 ]
Johannsson, Hjortur [1 ]
Nielsen, Arne Hejde [1 ]
Uhlen, Kjetil [2 ]
机构
[1] Tech Univ Denmark, Ctr Elect Power & Energy, Lyngby, Denmark
[2] Norwegian Univ Sci & Technol, Dept Elect Power Engn, Trondheim, Norway
来源
关键词
power system oscillations; power system stability; small signal stability; eigenvalue sensitivity; FREQUENCY ELECTROMECHANICAL MODES;
D O I
10.1109/PowerTech46648.2021.9495002
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This article presents a method to derive meaningful margins that provide information regarding the distance to critical oscillatory stability limits. The proposed method relies on modal torque concepts which allows to reduce the eigenvalue problem to a problem involving only generator torque and speed oscillations. The reduced problem size and the sparsity of the involved matrices makes it suitable for the application to large power systems. The algorithm relies on deriving the first order eigenvalue sensitivities in respect to perturbations of generator machine active power injections based on power flow quantities. The viability of the method is demonstrated at the example of the Nordic power system, showing the capability of determining critical operation well away from the actual critical stability limit.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] A direct method for calculating oscillatory stability limit of power system
    Liu, Xiaopeng
    Lu, Shirong
    Guo, Qiang
    Xia, Daozhi
    Dianli Xitong Zidonghue/Automation of Electric Power Systems, 1999, 23 (10):
  • [2] Direct method for calculating oscillatory stability limit of power system
    Liu, Xiaopeng
    Lu, Shirong
    Guo, Qiang
    Xia, Daozhi
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 1999, 23 (10): : 5 - 7
  • [3] Critical eigenvalue trajectory tracing for power system oscillatory stability assessment
    Wen, XY
    Ajjarapu, V
    2004 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1 AND 2, 2004, : 1883 - 1889
  • [4] Active limit equilibrium method of the stability analysis for soil slopes
    Huang, Ying
    Zhang, Zulian
    Jin, Kesheng
    ADVANCES IN INDUSTRIAL AND CIVIL ENGINEERING, PTS 1-4, 2012, 594-597 : 636 - 641
  • [5] A Direct Method to Determine the Stability of Power Systems During Transients
    Zhao, Yulin
    Zhang, Wei
    Liu, Ruiye
    2016 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2016, : 2255 - 2259
  • [6] APPLICATION OF THE PROBABILISTIC METHOD TO DETERMINE ACTIVE POWER VOLTAGE CONTROL COEFFICIENTS
    KIERNICKI, J
    KINSNER, K
    KORNAS, T
    ELECTRIC POWER SYSTEMS RESEARCH, 1989, 17 (03) : 239 - 242
  • [7] Calculation of Static Stability Limit of High Voltage Generator with Constant Active Power
    Ge Bao-jun
    Gu Feng-ling
    2009 INTERNATIONAL CONFERENCE ON SUSTAINABLE POWER GENERATION AND SUPPLY, VOLS 1-4, 2009, : 2241 - 2244
  • [8] A FAST METHOD FOR DETERMINING THE VOLTAGE STABILITY LIMIT OF A POWER-SYSTEM
    HAQUE, MH
    ELECTRIC POWER SYSTEMS RESEARCH, 1995, 32 (01) : 35 - 43
  • [9] CRITICAL ANALYSIS OF THE HARMONIC POWER FLOW METHOD TO DETERMINE THE DOMINANT DISTORTION SOURCE
    Santos, Ivan Nunes
    de Oliveira, Jose Carlos
    de Paula Silva, Sergio Ferreira
    XI BRAZILIAN POWER ELECTRONICS CONFERENCE (COBEP 2011), 2011, : 136 - 141
  • [10] Analysis of critical cutset based on operational variables and estimation of transient stability power limit
    NE China Inst. of Elec. Pwr. Eng., 132012, Jilin, China
    不详
    Dianli Xitong Zidonghue, 22 (11):