Two-Stage Approach for Detection and Reduction of Motion Artifacts in Photoplethysmographic Data

被引:192
|
作者
Krishnan, Rajet [1 ]
Natarajan, Balasubramaniam [1 ]
Warren, Steve [1 ]
机构
[1] Kansas State Univ, Dept Elect & Comp Engn, Manhattan, KS 66506 USA
关键词
Higher order statistics (HOS); independent component analysis (ICA); magnitude-based frequency-domain ICA (FD-ICA); motion artifact; motion detection unit (MDU); photoplethysmogram (PPG); SEPARATION;
D O I
10.1109/TBME.2009.2039568
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Corruption of photopleythysmograms (PPGs) by motion artifacts has been a serious obstacle to the reliable use of pulse oximeters for real-time, continuous state-of-health monitoring. In this paper, we propose an automated, two-stage PPG data processing method to minimize the effects of motion artifacts. The technique is based on our prior work related to motion artifact detection (stage 1) [R. Krishnan, B. Natarajan, and S. Warren, "Analysis and detection of motion artifacts in photoplethysmographic data using higher order statistics," in Proc. IEEE Int. Conf. Acoust., Speech, Signal Process. (ICASSP 2008), Las Vegas, Nevada, Apr. 2008, pp. 613-616] and motion artifact reduction (stage 2) [R. Krishnan, B. Natarajan, and S. Warren, " Motion artifact reduction in photoplethysmography using magnitude-based frequency domain independent component analysis," in Proc. 17th Int. Conf. Comput. Commun. Network, St. Thomas, Virgin Islands, Aug. 2008, pp. 1-5]. Regarding stage 1, we present novel and consistent techniques to detect the presence of motion artifact in PPGs given higher order statistical information present in the data. We analyze these data in the time and frequency domains (FDs) and identify metrics to distinguish between clean and motion-corrupted data. A Neyman-Pearson detection rule is formulated for each of the metrics. Furthermore, by treating each of the metrics as observations from independent sensors, we employ hard fusion and soft fusion techniques presented in [Z. Chair and P. Varshney, " Optimal data fusion in multiple sensor detection systems," IEEE Trans. Aerosp. Electron. Syst., AES, vol. 1, no. 1, pp. 98-101, Jan. 1986] and [C. C. Lee and J. J. Chao, " Optimum local decision space partitioning for distributed detection," IEEE Trans. Aerosp. Electron. Syst., AES, vol. 25, no. 7, pp. 536-544, Jul. 1989], respectively, in order to fuse individual decisions into a global system decision. For stage two, we propose a motion artifact reduction method that is effective even in the presence of severe subject movement. The approach involves an enhanced preprocessing unit consisting of a motion detection unit (MDU, developed in this paper), period estimation unit, and Fourier series reconstruction unit. The MDU identifies clean data frames versus those corrupted with motion artifacts. The period estimation unit determines the fundamental frequency of a corrupt frame. The Fourier series reconstruction unit reconstructs the final preprocessed signal by utilizing the spectrum variability of the pulse waveform. Preprocessed data are then fed to a magnitude-based FD independent component analysis unit. This helps reduce motion artifacts present at the frequencies of the reconstruction components. Experimental results are presented to demonstrate the efficacy of the overall motion artifact reduction method.
引用
收藏
页码:1867 / 1876
页数:10
相关论文
共 50 条
  • [1] Reduction of motion artifacts from photoplethysmographic recordings using a wavelet denoising approach
    Lee, CM
    Zhang, YT
    IEEE EMBS APBME 2003, 2003, : 194 - 195
  • [2] An Automatic Method for Motion Artifacts Detection in Photoplethysmographic Signals Referenced With Electrocardiography Data
    Vaz, Pedro
    Henriques, Jorge
    de Carvalho, Paulo
    Couceiro, Ricardo
    2014 7TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2014), 2014, : 704 - 708
  • [3] HHT based signal decomposition for reduction of motion artifacts in Photoplethysmographic signals
    Raghuram, M.
    Madhav, K. Venu
    Krishna, E. Hari
    Komalla, Nagarjuna Reddy
    Sivani, Kosaraju
    Reddy, K. Ashoka
    2012 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2012, : 1730 - 1734
  • [4] ANN-based damage detection with two-stage approach and model reduction
    Lu, Xuandong
    Zou, Yunfeng
    Cai, Chenzhi
    He, Xuhui
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2024,
  • [5] E2MD for Reduction of Motion Artifacts from Photoplethysmographic Signals
    Raghuram, M.
    Sivani, Kosaraju
    Reddy, K. Ashoka
    2014 INTERNATIONAL CONFERENCE ON ELECTRONICS AND COMMUNICATION SYSTEMS (ICECS), 2014,
  • [6] Robust two-stage approach for image motion estimation
    Tang, CY
    Hung, YP
    Chen, Z
    ELECTRONICS LETTERS, 1998, 34 (11) : 1091 - 1093
  • [7] A two-stage approach to saliency detection in images
    Wang, Zheshen
    Li, Baoxin
    2008 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING, VOLS 1-12, 2008, : 965 - 968
  • [8] A Two-Stage Beamforming Approach for Noise Reduction and Dereverberation
    Habets, Emanuel A. P.
    Benesty, Jacob
    IEEE TRANSACTIONS ON AUDIO SPEECH AND LANGUAGE PROCESSING, 2013, 21 (05): : 945 - 958
  • [9] Detection of motion artifacts in photoplethysmographic signals based on time and period domain analysis
    Couceiro, R.
    Carvalho, P.
    Paiva, R. P.
    Henriques, J.
    Muehlsteff, J.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 2603 - 2606
  • [10] Characterization and Reduction of Motion Artifacts in Photoplethysmographic Signals from a Wrist-worn Device
    Tautan, Alexandra-Maria
    Young, Alex
    Wentink, Eva
    Wieringa, Fokko
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 6146 - 6149