A Renewable C Reactive Protein Amperometric Immunosensor Based on Magnetic Multiwalled Carbon nanotubes Probles Modified Electrode

被引:9
|
作者
Zeng, Shaolin [1 ]
Zhou, Hankun [1 ]
Gan, Ning [1 ]
Cao, Yuting [1 ]
机构
[1] Ningbo Univ, Fac Mat Sci & Chem Engn, Ningbo 315211, Zhejiang, Peoples R China
关键词
N; N '-bis-(2-hydroxy-methylene)-o phenylenediamine cobalt; renewable electrode; magnetic carbon nanotube composite particles; CRP; magnetic; enzyme-free immunosensor;
D O I
10.4028/www.scientific.net/AMM.80-81.452
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A disposable, magnetism-controlled, and amperometric immunosensor was fabricated for the determination of C reactive protein (CRP). Firstly, Fe3O4 (core)/Au (shell) nanoparticle (GMP)-coated multiwalled carbon nanotubes (MWCNT-GMP) were prepared. Then, monoclonal antibody (anti-CRP) was immobilized on MWCNT-GMP to prepare MWCNT-GMP/anti-CRP composite magnetic probes. At last, the probes was adsorbed on the surface of N,N ''-bis-(2-hydroxy-methylene)-o-phenylenediamine cobalt (CoRb) modified, screen-printed carbon electrodes through external magnetic field. The amount of CRP in the serum sample was determined by one-step immunoassay. When different concentrations of CRP were added into25 mu L of phosphate-buffered solution (pH7.0) containing10(-4)M H2O2, the percentage of DPV cathodic peak current decrease (CR%) exhibited a linear relationship with the concentration of CRP in the range of 0.3-100 mu g L-1. The detection limit was 0.16 mu g L-1(3 delta). The immunosensor was used to determine CRP in serum samples of patients with heart diseases, and the results were consistent with those of the traditional ELISA method. The proposed amperometric immunosensor was sensitive, rapid, magnetic field-controlled, and disposable; therefore, it could be used to determine even traces of CRP in the blood serums of patients with heart diseases.
引用
收藏
页码:452 / 456
页数:5
相关论文
共 50 条
  • [1] Amperometric immunosensor based on multiwalled carbon nanotubes/Prussian blue/nanogold-modified electrode for determination of α-fetoprotein
    Jiang, Wen
    Yuan, Ruo
    Chai, Ya-Qin
    Yin, Bing
    ANALYTICAL BIOCHEMISTRY, 2010, 407 (01) : 65 - 71
  • [2] Amperometric Lactate Biosensor Based on Carbon Paste Electrode Modified with Benzo[c]cinnoline and Multiwalled Carbon Nanotubes
    Celik, Ali Cihan
    Ozturk, Funda
    Erden, Pinar Esra
    Kacar, Ceren
    Kilic, Esma
    ELECTROANALYSIS, 2015, 27 (12) : 2820 - 2828
  • [3] Application of multiwalled carbon nanotubes/ionic liquid modified electrode for amperometric determination of sulfadiazine
    Hong, Xiaoping
    Zhu, Yan
    Ma, Jingying
    DRUG TESTING AND ANALYSIS, 2012, 4 (12) : 1034 - 1039
  • [4] Disposable Amperometric Immunosensor for Hepatitis B Antigen Detection Based on Multiwalled Carbon Nanotubes and Ferrocene Decorated Screen Printed Electrode
    Chen, Zhencheng
    Bai, Yan
    Zhao, Feijun
    Cao, Liangli
    Han, Guocheng
    Yin, Shimin
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2019, 15 (05) : 930 - 938
  • [5] A novel amperometric immunosensor based on thionine/DNA self-assembled multilayers on carbon nanotubes modified glass carbon electrode
    Jia, Li-Yong
    Gan, Ning
    Zheng, Lei
    Wang, Qian
    MATERIALS SCIENCE AND ENGINEERING APPLICATIONS, PTS 1-3, 2011, 160-162 : 1170 - +
  • [6] An Amperometric Biological Toxic Hydrazine Sensor Based on Multiwalled Carbon Nanotubes and Iron Tetrasulfonated Phthalocyanine Composite Modified Electrode
    Devasenathipathy, Rajkumar
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    Karuppiah, Chelladurai
    Mani, Veerappan
    Ramaraj, Sayee Kannan
    Ali, M. Ajmal
    Al-Hemaid, Fahad M. A.
    ELECTROANALYSIS, 2015, 27 (06) : 1403 - 1410
  • [7] Multiwalled carbon nanotubes embedded molecularly imprinted polymer-modified screen printed carbon electrode for the quantitative analysis of C-reactive protein
    Kumar, Deepak
    Prasad, Bhim Bali
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 : 1141 - 1150
  • [8] Amperometric Immunosensor Based on a Protein A/Deposited Gold Nanocrystals Modified Electrode for Carbofuran Detection
    Sun, Xia
    Zhu, Ying
    Wang, Xiangyou
    SENSORS, 2011, 11 (12) : 11679 - 11691
  • [9] Amperometric hydrazine sensor using a glassy carbon electrode modified with gold nanoparticle-decorated multiwalled carbon nanotubes
    Hamidi, Hassan
    Bozorgzadeh, Somayyeh
    Haghighi, Behzad
    MICROCHIMICA ACTA, 2017, 184 (11) : 4537 - 4543
  • [10] Amperometric thrombin aptasensor using a glassy carbon electrode modified with polyaniline and multiwalled carbon nanotubes tethered with a thiolated aptamer
    Zhaohong Su
    Xiaolin Xu
    Haitao Xu
    Yi Zhang
    Chaorong Li
    Yan Ma
    Dongcheng Song
    Qingji Xie
    Microchimica Acta, 2017, 184 : 1677 - 1682