Analysis of gait with above-knee prosthesis using a new gait analysis system. Body's center of gravity and computer graphics

被引:0
|
作者
Irie, S
Iida, H
Kanzaki, H
Kawano, I
Mukai, K
Nakamura, T
机构
关键词
D O I
暂无
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Changes in the human body's center of gravity white walking with above. knee prosthesis were examined, using a new gait analysis system. This system can be synchronized with computer graphics (CG)which allow graphical representation and observation from any selected viewpoint. Three individuals with above-knee prothesis were enrolled in this study,including an individual in the early stages of training individual in the middle stages of gravity(COG)was analyzed in each of these individuals while they walked,using the above system,and was compared with the data from 3 healthy controls. The mean magnitude of dislocation of the COG was greater during prosthetic walking than during the walking of healthy individuals,as we had expected. However,this parameter for experienced artificial limb users was very close to that of healthy individuals. Synchronization of this analysis system with CG was found to allow simple indentification of problems even by inexperienced examiners.
引用
收藏
页码:413 / 416
页数:4
相关论文
共 41 条
  • [1] Dynamic analysis of above-knee amputee gait
    Bae, Tae Soo
    Choi, Kuiwon
    Hong, Daehie
    Mun, Museong
    CLINICAL BIOMECHANICS, 2007, 22 (05) : 557 - 566
  • [2] GAIT ANALYSIS IN A SERIES OF NORMAL SUBJECTS AS RELATED TO ABOVE-KNEE AMPUTEES
    LEAVITT, LA
    ZUNIGA, EN
    ISRAEL JOURNAL OF MEDICAL SCIENCES, 1973, 9 (05): : 592 - 598
  • [3] GAIT ANALYSIS AND TISSUE-SOCKET INTERFACE PRESSURES IN ABOVE-KNEE AMPUTEES
    LEAVITT, LA
    PETERSON, CR
    ZUNIGA, EN
    CALVERT, JC
    CANZONERI, J
    SOUTHERN MEDICAL JOURNAL, 1972, 65 (10) : 1197 - +
  • [4] Human Gait Analysis by Body Segmentation and Center of Gravity
    Tsao, Ying-Fang
    Liu, Wen-Te
    Chiu, Ching-Te
    2013 ASIA-PACIFIC SIGNAL AND INFORMATION PROCESSING ASSOCIATION ANNUAL SUMMIT AND CONFERENCE (APSIPA), 2013,
  • [5] Speed-dependent modulations of asymmetric center of body mass trajectory in the gait of above-knee amputee subjects
    Takiyama, Ken
    Yokoyama, Hikaru
    FRONTIERS IN SPORTS AND ACTIVE LIVING, 2024, 5
  • [6] Loads on the prosthesis-socket interface of above-knee amputees during normal gait: Validation of a multi-body simulation
    Schwarze, Michael
    Hurschler, Christof
    Seehaus, Frank
    Oehler, Simone
    Welke, Bastian
    JOURNAL OF BIOMECHANICS, 2013, 46 (06) : 1201 - 1206
  • [7] ANALYSIS OF A NEW POLYCENTRIC ABOVE-KNEE PROSTHESIS WITH A PNEUMATIC SWING PHASE-CONTROL
    PATIL, KM
    CHAKRABORTY, JK
    JOURNAL OF BIOMECHANICS, 1991, 24 (3-4) : 223 - 233
  • [8] ANALYSIS OF GAIT MOTION EQUATIONS AND APPLICATION OF PROPORTIONAL DERIVATIVE CONTROL FOR ELECTRONIC ABOVE KNEE PROSTHESIS
    Akdogan, Kurtulus Erinc
    Yilmaz, Atila
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2016, 31 (01): : 201 - 209
  • [9] A NEW GAIT ANALYSIS SYSTEM FOR CLINICAL USE IN A REHABILITATION CENTER
    HERMENS, HJ
    DEWAAL, CA
    BUURKE, J
    ZILVOLD, G
    ORTHOPEDICS, 1986, 9 (12) : 1669 - 1675
  • [10] Recommended number of strides for automatic assessment of gait symmetry and regularity in above-knee amputees by means of accelerometry and autocorrelation analysis
    Tura, Andrea
    Rocchi, Laura
    Raggi, Michele
    Cutti, Andrea G.
    Chiari, Lorenzo
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2012, 9