Dual-Layer Detector Spectral CT Performance: Quantitative Accuracy and Precision of Iodine Concentration Measurements

被引:0
|
作者
Zhao, X. [1 ]
Hameed, T. [2 ]
Hutchins, G. [1 ]
Liang, Y. [1 ]
机构
[1] Indiana Univ, Indianapolis, IN 46204 USA
[2] Indiana Univ Healthcare, Indianapolis, IN USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
WE-DE-605-
引用
收藏
页码:3233 / 3233
页数:1
相关论文
共 50 条
  • [1] Iodine Imaging at Spectral CT with a Dual-Layer Detector
    Ozguner, O.
    Dhanantwari, A.
    Halliburton, S.
    Wen, G.
    Utrup, S.
    Jordan, D.
    MEDICAL PHYSICS, 2016, 43 (06) : 3657 - 3657
  • [2] SNR performance comparison of dual-layer detector and dual-kVp spectral CT
    Heismann, B. J.
    Wirth, S.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3820 - 3822
  • [3] Accuracy of Electron Density, Effective Atomic Number, and Iodine Concentration Determination with Dual-Layer CT
    Hua, C.
    Shapira, N.
    Merchant, T.
    Klahr, P.
    Yagil, Y.
    MEDICAL PHYSICS, 2018, 45 (06) : E588 - E588
  • [4] Iodine concentration, HU accuracy, and metal artifacts evaluation on second-generation dual-layer spectral detector CT images with metal implants: a phantom study
    Zhang, Xinming
    Li, Hanwei
    Wang, Haowen
    Liu, Xiaomin
    Deng, Weiwei
    Zhong, Jianqiu
    Fan, Litian
    Ling, Qingqing
    Hu, Debin
    Qi, Hongliang
    Chen, Hongwen
    ACTA RADIOLOGICA, 2024, 65 (09) : 1030 - 1038
  • [5] Objective Image Characterization of Spectral CT with a Dual-Layer Detector
    Ozguner, O.
    Halliburton, S.
    Dhanantwari, A.
    Wen, G.
    Utrup, S.
    Jordan, D.
    MEDICAL PHYSICS, 2016, 43 (06) : 3836 - 3836
  • [6] Effects of radiation dose levels and spectral iterative reconstruction levels on the accuracy of iodine quantification and virtual monochromatic CT numbers in dual-layer spectral detector CT: an iodine phantom study
    Lu, Xiaomei
    Lu, Zaiming
    Yin, Jiandong
    Gao, Yuying
    Chen, Xingbiao
    Guo, Qiyong
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (02) : 188 - 200
  • [7] Quantitative Assessment of Radiologically Indeterminate Local Colonic Wall Thickening on Iodine Density Images Using Dual-Layer Spectral Detector CT
    Wang, Guorong
    Fang, Yue
    Wang, Zhiwei
    Jin, Zhengyu
    ACADEMIC RADIOLOGY, 2021, 28 (10) : 1368 - 1374
  • [8] Dual-Energy (Spectral) Late Iodine Enhancement Cardiac CT: Does a Dual-Layer Detector Make It Work?
    Litt, Harold, I
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2019, 1 (01):
  • [9] Accuracy of bone mineral density quantification using dual-layer spectral detector CT: a phantom study
    van Hamersvelt, Robbert W.
    Schilham, Arnold M. R.
    Engelke, Klaus
    den Harder, Annemarie M.
    de Keizer, Bart
    Verhaar, Harald J.
    Leiner, Tim
    de Jong, Pim A.
    Willemink, Martin J.
    EUROPEAN RADIOLOGY, 2017, 27 (10) : 4351 - 4359
  • [10] Accuracy of bone mineral density quantification using dual-layer spectral detector CT: a phantom study
    Robbert W. van Hamersvelt
    Arnold M. R. Schilham
    Klaus Engelke
    Annemarie M. den Harder
    Bart de Keizer
    Harald J. Verhaar
    Tim Leiner
    Pim A. de Jong
    Martin J. Willemink