Performance evaluation of a hand-held, semiconductor (CdZnTe)-based gamma camera

被引:51
|
作者
Abe, A [1 ]
Takahashi, N [1 ]
Lee, J [1 ]
Oka, T [1 ]
Shizukuishi, K [1 ]
Kikuchi, T [1 ]
Inoue, T [1 ]
Jimbo, M [1 ]
Ryuo, H [1 ]
Bickel, C [1 ]
机构
[1] Yokohama City Univ, Sch Med, Dept Radiol, Kanazawa Ku, Yokohama, Kanagawa 232, Japan
关键词
performance; semiconductor; CdZnTe; gamma camera; detector;
D O I
10.1007/s00259-002-1067-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have designed and developed a small field of view gamma camera, the eZ SCOPE, based on use of a CdZnTe semiconductor. This device utilises proprietary signal processing technology and an interface to a computer-based imaging system. The purpose of this study was to evaluate the performance of the eZ scope in comparison with currently employed gamma camera technology. The detector is a single wafer of 5-mm-thick CdZnTe that is divided into a 16 x 16 array (256 pixels). The sensitive area of the detector is a square of dimension 3.2 cm. Two parallel-hole collimators are provided with the system and have a matching (256 hole) pattern to the CdZnTe detector array: a low-energy, high-resolution parallel-hole (LEHR) collimator fabricated of lead and a low-energy, high-sensitivity parallel-hole (LEHS) collimator fabricated of tungsten. Performance measurements and the data analysis were done according to the procedures of the NEMA standard. We also studied the long-term stability of the system with continuous use and variations in ambient temperature. Results were as follows. Intrinsic energy resolution: 8.6% FWHM at 141 keV. Linearity: There was excellent linearity between the observed photopeaks and the known gamma ray energies for the given isotopes. Intrinsic system uniformity: For the central field of view, the integral uniformity and the differential uniformity were, respectively, 1.6% and 1.3% with the LEHR collimator and 1.9% and 1.2% with the LEHS collimator. System spatial resolution: The FWHM measurements made at the surface of the collimator were 2.2 mm (LEHR) and 2.9 mm (LEHS). Contrast test: The average S/N ratios (i.e. counts in the irradiated pixel divided by counts in the surrounding pixels) for the inner ring pixels (8)/outer ring pixels (16) using the LEHS collimator and LEHR collimator were 3.2%/0.2% and 3.7%/0.3%, respectively. Count rate characteristics: We could not determine the maximum count rate and the 20% loss count rate from these data because the plateau was not reached while using the solutions measured. System sensitivity: The average acquisitions were 11,052 cpm/MBq (LEHR) and 28,590 cpm/MBq (LEHS). Temperature dependence: The system displayed minimum corresponding shift in cps with temperature changes in the measured temperature range. We designed and developed a semiconductor-based gamma camera using CdZnTe. The basic performance of this camera compares favourably with the existing gamma camera technology that is deployed in the medical field today. The most significant differences include the spatial resolution, sensitivity, high count rate characteristics and energy resolution. We believe that this device will be of value for a number of clinical applications including sentinel node detection and radiopharmaceutical-guided surgery.
引用
收藏
页码:805 / 811
页数:7
相关论文
共 50 条
  • [1] Performance evaluation of a hand-held, semiconductor (CdZnTe)-based gamma camera
    Aya Abe
    Nobukazu Takahashi
    Jin Lee
    Takashi Oka
    Kazuya Shizukuishi
    Tatsuya Kikuchi
    Tomio Inoue
    Masao Jimbo
    Hideki Ryuo
    Chris Bickel
    European Journal of Nuclear Medicine and Molecular Imaging, 2003, 30 : 805 - 811
  • [2] Performance evaluation of a hand held, semiconductor (CdZnTe) based gamma camera.
    Abe, A
    Takahashi, N
    Shizukuishi, K
    Nakagami, Y
    Torigoe, S
    Lee, J
    Ozawa, Y
    Jimbo, M
    Ryuo, H
    Inoue, T
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 279P - 279P
  • [3] Imaging performance of a prototype hand-held gamma camera for surgical use
    Tsuchimochi, M
    Sakahara, H
    Hayama, K
    Funaki, M
    Shirahata, T
    Orskaug, T
    RADIOLOGY, 2001, 221 : 127 - 127
  • [4] High-resolution hand-held gamma camera
    MacDonald, LR
    Patt, BE
    Iwanczyk, JS
    Yamaguchi, Y
    McElroy, D
    Hoffman, EJ
    Aarsvold, JN
    Mintzer, RA
    Alazraki, NP
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS II, 2000, 4142 : 242 - 253
  • [5] Benchmark Evaluation of a Hand-Held Beta Camera
    Bates, Thomas
    Nham, Kien
    Nataneli, Albert
    Wu, Yibao
    Chi, Yujie
    Daghighian, Farhad
    Jin, Mingwu
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [6] Hand-held gamma probe or hand-held miniature gamma camera for minimally invasive parathyroidectomy: competition, evolution or synergy?
    Domenico Rubello
    Giuliano Mariani
    European Journal of Nuclear Medicine and Molecular Imaging, 2007, 34 : 162 - 164
  • [7] Hand-held gamma probe or hand-held miniature gamma camera for minimally invasive parathyroidectomy: competition, evolution or synergy?
    Rubello, Domenico
    Mariani, Giuliano
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (02) : 162 - 164
  • [8] Imaging performance of a prototype hand-held gamma camera for surgical use.
    Tsuchimochi, M
    Sakahara, H
    Hayama, K
    Funaki, M
    Shirahata, T
    Orskaug, T
    Maehlum, G
    Yoshioka, K
    Nygard, E
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A506 - A506
  • [9] Evaluation of hand-held gamma camera with 1-mm NaI(Tl) pixels
    Yamaguchi, Y
    MacDonald, LR
    Patt, BE
    Iwanczyk, JS
    Aarsvold, JN
    Mintzer, RA
    Alazraki, NP
    Greene, CM
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS IV, 2002, 4786 : 103 - 113
  • [10] EVALUATION OF CAMERA SHAKE BY HAND-HELD SPECKLE PHOTOGRAPHY
    BURCH, JM
    ENNOS, AE
    QUINN, GB
    ISRAEL JOURNAL OF TECHNOLOGY, 1980, 18 (05): : 271 - 274