Langmuir probe without RF compensation

被引:1
|
作者
Dvorak, P. [1 ]
Palenik, J. [1 ]
Tkacik, M. [1 ]
Pospisil, Z. [1 ]
机构
[1] Masaryk Univ, Fac Sci, Kotlarska 2, Brno 61137, Czech Republic
来源
PLASMA SOURCES SCIENCE & TECHNOLOGY | 2022年 / 31卷 / 08期
关键词
plasma; Langmuir probe; capacitively coupled discharge; RF compensation;
D O I
10.1088/1361-6595/ac83eb
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
Langmuir probes with RF compensation are used for measurements of electron concentration, electron temperature and the DC value of plasma potential in RF discharges. In order to obtain all the RF components of plasma potential, simple probes without RF compensation are used. However, it has been believed that these uncompensated probes can not be used for determination of the DC value of plasma potential and of electron concentration and temperature, since their VA characteristics is distorted by the RF current. Consequently, the evaluation of data measured with uncompensated probes was not possible without additional measurement with a RF compensated Langmuir probe. This contribution analyzes the possibility to use uncompensated probes not only for measurement of RF components of plasma potential, but also for measurement of the DC component of plasma potential, electron concentration and electron temperature.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Langmuir probe measurements at incomplete rf-compensation
    Hannemann, M.
    Sigeneger, F.
    CZECHOSLOVAK JOURNAL OF PHYSICS, 2006, 56 : B740 - B748
  • [2] Langmuir probe RF plasma compensation using a simulation method
    Azooz, A. A.
    Al-Jawaady, Y. A.
    Ali, Z. T.
    COMPUTER PHYSICS COMMUNICATIONS, 2014, 185 (01) : 350 - 356
  • [3] RF compensation of single Langmuir probe in low density helicon plasma
    Ghosh, Soumen
    Chattopadhyay, Prabal K.
    Ghosh, Joydeep
    Bora, Dhiraj
    FUSION ENGINEERING AND DESIGN, 2016, 112 : 915 - 918
  • [4] Langmuir double probe RF plasma compensation using simulation metho
    Azooz, Aasim A.
    Akbar, Demiral S.
    Bilikmen, Sinan
    Acta Technica CSAV (Ceskoslovensk Akademie Ved), 2010, 55 (04): : 357 - 382
  • [5] COMPARISON BETWEEN RF PROBE AND LANGMUIR PROBE MEASUREMENTS
    PETER, G
    PHYSICS LETTERS A, 1967, A 25 (02) : 171 - +
  • [6] RF harmonic suppression in Langmuir probe measurements in RF discharges
    Flender, U
    Thi, BHN
    Wiesemann, K
    Khromov, NA
    Kolokolov, NB
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 1996, 5 (01): : 61 - 69
  • [7] RF compensation of double Langmuir probes: modelling and experiment
    Caneses, Juan F.
    Blackwell, Boyd
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2015, 24 (03):
  • [8] Multiple harmonic compensation of Langmuir probes in rf discharges
    Dyson, A
    Bryant, P
    Allen, JE
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2000, 11 (05) : 554 - 559
  • [9] LANGMUIR PROBE CHARACTERISTICS IN RF GLOW-DISCHARGES
    HERSHKOWITZ, N
    CHO, MH
    NAM, CH
    INTRATOR, T
    PLASMA CHEMISTRY AND PLASMA PROCESSING, 1988, 8 (01) : 35 - 52
  • [10] VARIATION OF RF RESPONSE OF A LANGMUIR PROBE WITH AMPLITUDE AND FREQUENCY
    SMY, PR
    NATION, JA
    SIMPSON, D
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1969, 2 (08) : 1095 - &