Highly sensitive inhibitory kinetics fluorescence method for determination of arsenic

被引:0
|
作者
Li, Guirong [1 ]
Liu, Yunfu [1 ]
机构
[1] Univ S China, Coll Publ Hlth, Hengyang 421001, Peoples R China
关键词
arsenic; inhibitory kinetics fluorescence; Acridine red; food products; ATOMIC-ABSORPTION-SPECTROMETRY; NORMAL-COORDINATE ANALYSIS; FOURIER-TRANSFORM RAMAN; INFRARED-SPECTRA; WATER SAMPLES; ICP-MS; SYSTEM; OPTIMIZATION; URINE; BISMUTH;
D O I
10.1080/03067310903207618
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new and highly sensitive inhibitory kinetic fluorescence method for the determination of arsenic (III) has been established based on its inhibitory effect on the oxidation reaction of Acridine red (ADR) by KBrO(3) in sulphuric acid medium. The reaction has been followed by measuring the enhancement of fluorescence at 550 nm. It relies on the linear relationship where the change in the fluorescence (Delta F) versus added As(III) amounts in the range of 0-0.450 mu g mL(-1) is plotted, under the optimum conditions. The sensitivity of the proposed method, i.e. the limit of detection, is 2.1 x 10(-2) ng mL(-1). The method is featured with good accuracy and reproducibility for arsenic (III) determination. This method was successfully applied for the quantitative determination of arsenic (III) in food products samples, and the relative standard deviations and the recoveries were in ranges of 2.31-2.83% and 90.0-107.2%, respectively. A review of recently published catalytic or inhibiting kinetic methods for the determination of arsenic (III) has also been presented for comparison. The mechanism of reaction was studied.
引用
收藏
页码:866 / 875
页数:10
相关论文
共 50 条
  • [1] A HIGHLY SENSITIVE SPECTROPHOTOMETRIC METHOD FOR DETERMINATION OF MICRO-AMOUNTS OF ARSENIC
    WU, QF
    LIU, PF
    TALANTA, 1983, 30 (04) : 275 - 276
  • [2] Inhibitory kinetics spectrophotometric determination of trace arsenic (V)
    Peng, X
    Chen, GS
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (01) : 38 - 40
  • [3] A highly sensitive fluorescence immunoassay for the determination of diethylstilbestrol
    Wang, Xinyi
    Dong, Wen
    Xue, Weili
    Wang, Shuhao
    PROGRESS IN ENVIRONMENTAL PROTECTION AND PROCESSING OF RESOURCE, PTS 1-4, 2013, 295-298 : 622 - 625
  • [4] Highly selective and sensitive determination of copper ion based on a visual fluorescence method
    Chen, Linfeng
    Tian, Xike
    Yang, Chao
    Li, Yong
    Zhou, Zhaoxin
    Wang, Yanxin
    Xiang, Fang
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 240 : 66 - 75
  • [5] A fluorescence quenching method for determination of arsenic(III)
    Feng, SL
    Tang, A
    Fan, J
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (11) : 1315 - 1317
  • [6] Simple and sensitive determination of arsenic by volatile arsenic trichloride generation atomic fluorescence spectrometry
    Li, Xiaohong
    Su, Yingying
    Xu, Kailai
    Hou, Xiandeng
    Lv, Yi
    TALANTA, 2007, 72 (05) : 1728 - 1732
  • [7] A HIGHLY SENSITIVE METHOD FOR DETERMINATION OF MOLECULAR-WEIGHTS OF NEUTRAL OLIGOSACCHARIDES BY FLUORESCENCE LABELING
    HASE, S
    IKENAKA, T
    MATSUSHIMA, Y
    JOURNAL OF BIOCHEMISTRY, 1981, 90 (05): : 1275 - 1279
  • [8] A sensitive spectrophotometric method for the determination of arsenic in environmental samples
    Revanasiddappa, H. D.
    Dayananda, B. P.
    Kumar, T. N. K.
    ENVIRONMENTAL CHEMISTRY LETTERS, 2007, 5 (03) : 151 - 155
  • [9] A sensitive spectrophotometric method for the determination of arsenic in environmental samples
    H. D. Revanasiddappa
    B. P. Dayananda
    T. N. K. Kumar
    Environmental Chemistry Letters, 2007, 5 : 151 - 155
  • [10] Development of a highly sensitive fluorescence method for tartrazine determination in food matrices based on carbon dots
    Liu, Lingfei
    Sun, Huijuan
    Xiao, Lixia
    Yang, Zhen-quan
    Han, Jie
    Gong, Xiaojuan
    Hu, Qin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (05) : 1485 - 1492