Rapid response radiation sensors for Homeland Security applications

被引:2
|
作者
Mukhopadhyay, Sanjoy [1 ]
Maurer, Richard [1 ]
Guss, Paul [2 ]
机构
[1] Natl Secur Technol LLC, Remote Sensing Lab Andrews, Bldg 1783,Arnold Ave, Andrews AFB, MD 20762 USA
[2] Natl Secur Technol LLC, Remote Sensing Lab Nellis, Las Vegas, NV 89193 USA
关键词
gamma detector; false alarm rate; sub-second data acquisition; threat signature;
D O I
10.1117/12.2066666
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The National Security Technologies, LLC, Remote Sensing Laboratory is developing a rapid response radiation detection system for homeland security field applications. The intelligence-driven system is deployed only when non-radiological information about the target is verifiable. The survey area is often limited, so the detection range is small; in most cases covering a distance of 10 meters or less suffices. Definitive response is required in no more than 3 seconds and should minimize false negative alarms, but can err on the side of positive false alarms. The detection system is rapidly reconfigurable in terms of size, shape, and outer appearance; it is a plug-and-play system. Multiple radiation detection components (viz., two or more sodium iodide scintillators) are used to independently "over-determine" the existence of the threat object. Rapid response electronic dose rate meters are also included in the equipment suite. Carefully studied threat signatures are the basis of the decision making. The use of Rad-Detect predictive modeling provides information on the nature of the threat object. Rad-Detect provides accurate dose rate from heavily shielded large sources; for example those lost in Mexico were Category 1 radiation sources (similar to 3,000 Ci of Co-60), the most dangerous of five categories defined by the International Atomic Energy Agency. Taken out of their shielding containers, Category 1 sources can kill anyone who is exposed to them at close range for a few minutes to an hour. Whenever possible sub-second data acquisition will be attempted, and, when deployed, the system will be characterized for false alarm rates. Although the radiation detection materials selected are fast (viz., faster scintillators), their speed is secondary to sensitivity, which is of primary importance. Results from these efforts will be discussed and demonstrated.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] SMART sensors for homeland security applications
    Lind, MA
    Wright, BW
    NONDESTRUCTIVE DETECTION AND MEASUREMENT FOR HOMELAND SECURITY II, 2004, 5395 : 1 - 7
  • [2] Wireless sensors and sensor networks for homeland security applications
    Potyrailo, Radislav A.
    Nagraj, Nandini
    Surman, Cheryl
    Boudries, Hacene
    Lai, Hanh
    Slocik, Joseph M.
    Kelley-Loughnane, Nancy
    Naik, Rajesh R.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2012, 40 : 133 - 145
  • [3] Test of radiation detectors used in homeland security applications
    Pibida, L
    Minniti, R
    O'Brien, A
    Unterweger, A
    HEALTH PHYSICS, 2005, 88 (05): : S84 - S90
  • [4] COLL 65-SERS sensors for homeland security applications
    Van Duyne, Richard P.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2009, 238
  • [5] Bayesian performance metrics of binary sensors in Homeland Security applications
    Jannson, Tomasz P.
    Forrester, Thomas C.
    SENSORS, AND COMMAND, CONTROL, COMMUNICATIONS, AND INTELLIGENCE (C3I) TECHNOLOGIES FOR HOMELAND SECURITY AND HOMELAND DEFENSE VII, 2008, 6943
  • [6] Tapping vehicle sensors for homeland security
    Gerla, Mario
    Lee, Uichin
    HOMELAND SECURITY TECHNOLOGY CHALLENGES: FROM SENSING AND ENCRYPTING TO MINING AND MODELING, 2008, : 177 - +
  • [7] Radiation scientists and homeland security
    Rose, CM
    RADIATION RESEARCH, 2002, 157 (05) : 607 - 609
  • [8] CURRENT STATE OF COMMERCIAL RADIATION DETECTION EQUIPMENT FOR HOMELAND SECURITY APPLICATIONS
    Klann, Raymond T.
    Shergur, Jason
    Mattesich, Gary
    NUCLEAR TECHNOLOGY, 2009, 168 (01) : 79 - 88
  • [9] Irradiation applications for homeland security
    Desrosiers, MF
    RADIATION PHYSICS AND CHEMISTRY, 2004, 71 (1-2) : 479 - 482
  • [10] Chemical Sensors for Environmental Monitoring and Homeland Security
    Sekhar, Praveen K.
    Brosha, Eric L.
    Mukundan, Rangachary
    Garzon, Fernando H.
    ELECTROCHEMICAL SOCIETY INTERFACE, 2010, 19 (04): : 35 - 40