Management of a case of transient neonatal diabetes mellitus using continuous glucose monitoring

被引:5
|
作者
Iwata, Naoya [1 ]
Asui, Risa [1 ]
Mizumoto, Hiroshi [1 ]
Hata, Daisuke [1 ]
机构
[1] Kitano Hosp, Tazuke Kofukai Med Res Inst, Dept Pediat, Osaka, Japan
关键词
continuous glucose monitoring; hyperglycemia; 6q24-related diabetes; neonatal diabetes mellitus; RISK; 6Q24;
D O I
10.1297/cpe.29.77
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Neonatal diabetes mellitus (NDM) is a very rare disorder and its diagnosis can be challenging especially in mild and transient cases. Herein, we describe a 2.4-kg female infant born at 38 wk of gestation who showed hyperglycemia (388 mg/dL) on Day 1. Intermittent blood sampling showed glucose concentrations of 100-150 mg/dL on Day 2-5. However, continuous glucose monitoring (CGM) from Day 7 revealed hyperglycemia (> 200 mg/dL) after every feeding. The patient required low-dose (0.1-0.2 U/kg/d) insulin therapy for a short period (7 d). During the treatment, hypoglycemic (< 50 mg/dL) events were not detected by real- time CGM. Follow-up CGM from Day 32 showed normoglycemia for 3 full days; therefore, we ascertained that the diabetes had been transient. Later genetic analysis revealed an abnormal methylation pattern on chromosome 6q24, which is the most frequent cause of transient NDM. Most cases of 6q24-related NDM relapse after puberty, implying that long term follow up is required. We speculate that the NDM in this case might not have been diagnosed without CGM. This report highlights the usefulness of CGM for the initial diagnosis, monitoring during insulin therapy, and confirmation of improvement in patients with transient NDM.
引用
收藏
页码:77 / 80
页数:4
相关论文
共 50 条
  • [1] Continuous Glucose Monitoring in Transient Neonatal Diabetes Mellitus-2 Case Reports and Literature Review
    Chisnoiu, Tatiana
    Balasa, Adriana Luminita
    Mihai, Larisia
    Lupu, Ancuta
    Frecus, Corina Elena
    Ion, Irina
    Andrusca, Antonio
    Pantazi, Alexandru Cosmin
    Nicolae, Maria
    Lupu, Vasile Valeriu
    Ionescu, Constantin
    Mihai, Cristina Maria
    Cambrea, Simona Claudia
    DIAGNOSTICS, 2023, 13 (13)
  • [2] Glucose-monitoring with continuous subcutaneous microdialysis in neonatal diabetes mellitus
    Baumeister, F. A. M.
    Hack, A.
    Busch, R.
    KLINISCHE PADIATRIE, 2006, 218 (04): : 230 - 232
  • [3] Use of continuous glucose monitoring to improve diabetes mellitus management
    Ellis, Samuel L.
    Bookout, Tevin
    Garg, Satish K.
    Izuora, Kenneth E.
    ENDOCRINOLOGY AND METABOLISM CLINICS OF NORTH AMERICA, 2007, 36 : 46 - 68
  • [4] A Case of Transient Neonatal Diabetes Mellitus
    Hewes, Hilary A.
    Dudley, Nanette C.
    Adelgais, Kathleen M.
    PEDIATRIC EMERGENCY CARE, 2010, 26 (12) : 930 - 931
  • [5] Diabetic Technology Update Continuous Glucose Monitoring Systems In The Management Of Diabetes Mellitus
    Sridhar, C.
    Krithika, C.
    JOURNAL OF PHARMACEUTICAL NEGATIVE RESULTS, 2022, 13 : 1973 - 1977
  • [6] Importance of continuous glucose monitoring in the treatment of diabetes mellitus
    Moon, Sun Joon
    Lee, Won-Young
    JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2023, 66 (07): : 432 - 438
  • [7] Continuous glucose monitoring in type 1 diabetes mellitus
    Pavlicek, Vojtech
    DIABETOLOGE, 2019, 15 (08): : 744 - 746
  • [8] Continuous glucose monitoring in type 1 diabetes mellitus
    Tamborlane, William V.
    Beck, Roy W.
    LANCET, 2009, 373 (9677): : 1744 - 1746
  • [9] Practical Considerations for Using Continuous Glucose Monitoring in Patients with Gestational Diabetes Mellitus
    Castorino, Kristin
    Durnwald, Celeste
    Ehrenberg, Stacey
    Ehrhardt, Nicole
    Isaacs, Dianna
    Levy, Carol J.
    Valent, Amy M.
    JOURNAL OF WOMENS HEALTH, 2025, 34 (01) : 10 - 20
  • [10] Role of continuous glucose monitoring in diabetes management
    Moser, E. G.
    Crew, L. B.
    Garg, S. K.
    AVANCES EN DIABETOLOGIA, 2010, 26 (02): : 73 - 78